메뉴 건너뛰기




Volumn 25, Issue 10, 2003, Pages 781-785

A new contingency analysis approach for voltage collapse assessment

Author keywords

Contingency analysis; Tangent vector; Voltage collapse

Indexed keywords

COMPUTATIONAL METHODS; ELECTRIC LOADS; ELECTRIC POTENTIAL; VECTORS;

EID: 0043011886     PISSN: 01420615     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0142-0615(03)00030-9     Document Type: Article
Times cited : (8)

References (15)
  • 1
    • 0029255370 scopus 로고
    • Conditions for saddle-node bifurcations in ac/dc power systems
    • Cañizares C.A. Conditions for saddle-node bifurcations in ac/dc power systems. Electric Power Energy Syst. 17:(1):1995;61-68.
    • (1995) Electric Power Energy Syst , vol.17 , Issue.1 , pp. 61-68
    • Cañizares, C.A.1
  • 3
    • 0029410162 scopus 로고
    • Estimating the loading limit margin taking into account voltage collapse areas
    • New York; January 20-February 2
    • Barquín J, Goméz T, Pagola F.L. Estimating the loading limit margin taking into account voltage collapse areas. IEEE/PES Winter Meeting-Paper 95 WM 183-4 PWRS, New York; January 20-February 2 1995.
    • (1995) IEEE/PES Winter Meeting-Paper 95 WM 183-4 PWRS
    • Barquín, J.1    Goméz, T.2    Pagola, F.L.3
  • 4
    • 0026953350 scopus 로고
    • Voltage stability evaluation using modal analysis
    • Gao B., Morrison G.K., Kundur P. Voltage stability evaluation using modal analysis. IEEE Trans Power Syst. 7:(4):1992;1529-1542.
    • (1992) IEEE Trans Power Syst , vol.7 , Issue.4 , pp. 1529-1542
    • Gao, B.1    Morrison, G.K.2    Kundur, P.3
  • 6
    • 0010309306 scopus 로고
    • Voltage stability: Phenomena characterization based on reactive control effects and system critical areas identification
    • Belo Horizonte
    • Prada R.B., Zambroni de Souza A.C., Filho X.V., Massaud A.G., Oliveira J.C. Voltage stability: phenomena characterization based on reactive control effects and system critical areas identification. Proceedings of the third SEPOPE meeting, Belo Horizonte. 1991.
    • (1991) Proceedings of the Third SEPOPE Meeting
    • Prada, R.B.1    De Souza, A.C.Z.2    Filho, X.V.3    Massaud, A.G.4    Oliveira, J.C.5
  • 7
    • 0027544699 scopus 로고
    • Point of collapse and continuation methods for large ac/dc systems
    • Cañizares C.A., Alvarado F.L. Point of collapse and continuation methods for large ac/dc systems. IEEE Trans Power Syst. 8:(1):1993;1-8.
    • (1993) IEEE Trans Power Syst , vol.8 , Issue.1 , pp. 1-8
    • Cañizares, C.A.1    Alvarado, F.L.2
  • 8
    • 0026908086 scopus 로고
    • Voltage security enhancement using energy based sensitivities
    • Overbye T.J., DeMarco C.L. Voltage security enhancement using energy based sensitivities. IEEE Trans Power Syst. 7:(3):1992;1001-1011.
    • (1992) IEEE Trans Power Syst , vol.7 , Issue.3 , pp. 1001-1011
    • Overbye, T.J.1    DeMarco, C.L.2
  • 11
    • 0031197260 scopus 로고    scopus 로고
    • New techniques to speed up voltage collapse computations using tangent vectors
    • Zambroni de Souza A.C., Cañizares C.A., Quintana V.H. New techniques to speed up voltage collapse computations using tangent vectors. IEEE Trans Power Syst. 12:(3):1997;1380-1387.
    • (1997) IEEE Trans Power Syst , vol.12 , Issue.3 , pp. 1380-1387
    • De Souza, A.C.Z.1    Cañizares, C.A.2    Quintana, V.H.3
  • 15
    • 0032188190 scopus 로고    scopus 로고
    • Tangent vector as a tool voltage collapse and losses sensitivity studies
    • Zambroni de Souza AC. Tangent vector as a tool voltage collapse and losses sensitivity studies, Electric Power Syst Research 1998;47(1):65-70.
    • (1998) Electric Power Syst Research , vol.47 , Issue.1 , pp. 65-70
    • De Souza, A.C.Z.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.