메뉴 건너뛰기




Volumn 17, Issue 7, 2003, Pages 496-502

Proximal tibial fracture stability with intramedullary nail fixation using oblique interlocking screws

Author keywords

Bone biomechanics; Fracture; Intramedullary nail; Tibia

Indexed keywords

ADULT; AGED; ANALYSIS OF VARIANCE; ARTICLE; BIOMECHANICS; BONE DENSITY; BONE NAIL; BONE PLATE; BONE SCREW; CONTROLLED STUDY; FEMALE; HUMAN; HUMAN TISSUE; IN VITRO STUDY; INTERMETHOD COMPARISON; INTRAMEDULLARY NAILING; JOINT FUNCTION; LINEAR REGRESSION ANALYSIS; MALE; MECHANICAL STRESS; OSTEOSYNTHESIS; PLATE FIXATION; PRIORITY JOURNAL; PROXIMAL TIBIA FRACTURE; RANDOMIZATION; TIBIA PROXIMAL OSTEOTOMY; TIBIA TORSION; TRABECULAR BONE;

EID: 0042975353     PISSN: 08905339     EISSN: None     Source Type: Journal    
DOI: 10.1097/00005131-200308000-00004     Document Type: Article
Times cited : (79)

References (28)
  • 1
    • 0029005359 scopus 로고
    • Proximal third tibial shaft fractures: Should they be nailed?
    • Lang GJ, Cohen BE, Bosse MJ, et al. Proximal third tibial shaft fractures: should they be nailed? Clin Orthop. 1995;315:64-74.
    • (1995) Clin. Orthop. , vol.315 , pp. 64-74
    • Lang, G.J.1    Cohen, B.E.2    Bosse, M.J.3
  • 2
    • 0035349444 scopus 로고    scopus 로고
    • Nonarticular proximal tibia fracture: Treatment options and decision making
    • Bono CM, Levine RG, Rao JP, et al. Nonarticular proximal tibia fracture: treatment options and decision making. J Am Acad Orthop Surg. 2001;9:176-186.
    • (2001) J. Am. Acad. Orthop. Surg. , vol.9 , pp. 176-186
    • Bono, C.M.1    Levine, R.G.2    Rao, J.P.3
  • 3
    • 0031752933 scopus 로고    scopus 로고
    • Combined internal and external osteosynthesis a biological approach to the treatment of complex fractures of the proximal tibia
    • Gerber A, Ganz R. Combined internal and external osteosynthesis a biological approach to the treatment of complex fractures of the proximal tibia. Injury. 1998;29(suppl 3):c22-c28.
    • (1998) Injury , vol.29 , Issue.SUPPL. 3
    • Gerber, A.1    Ganz, R.2
  • 4
    • 0029053626 scopus 로고
    • Radiographic analysis of tibial fracture malalignment following intramedullary nailing
    • Freedman EL, Johnson EE. Radiographic analysis of tibial fracture malalignment following intramedullary nailing. Clin Orthop. 1995;315:25-33.
    • (1995) Clin. Orthop. , vol.315 , pp. 25-33
    • Freedman, E.L.1    Johnson, E.E.2
  • 5
    • 0033219711 scopus 로고    scopus 로고
    • The mechanical effect of blocking screws ("Poller screws") in stabilizing tibia fractures with short proximal or distal fragments after insertion of small-diameter intramedullary nails
    • Krettek C, Miclau T, Schandelmaier P, et al. The mechanical effect of blocking screws ("Poller screws") in stabilizing tibia fractures with short proximal or distal fragments after insertion of small-diameter intramedullary nails. J Orthop Trauma. 1999;13:550-553.
    • (1999) J. Orthop. Trauma , vol.13 , pp. 550-553
    • Krettek, C.1    Miclau, T.2    Schandelmaier, P.3
  • 6
    • 0043095574 scopus 로고    scopus 로고
    • M/DN® Tibial and Humeral Nail Intramedullary Fixation, Surgical Techniques© 1998. Zimmer, Inc., Warsaw, Indiana
    • Kyle RF, Winquist RA. M/DN® Tibial and Humeral Nail Intramedullary Fixation, Surgical Techniques© 1998. 2000 Zimmer, Inc., Warsaw, Indiana.
    • (2000)
    • Kyle, R.F.1    Winquist, R.A.2
  • 7
    • 0033953162 scopus 로고    scopus 로고
    • Fixation of proximal tibia fractures by a retrograde nail: A biomechanical investigation
    • Pommer A, Wieser A, Hahn MP, et al. Fixation of proximal tibia fractures by a retrograde nail: a biomechanical investigation. Arch Orthop Trauma Surg. 2000;120:212-214.
    • (2000) Arch. Orthop. Trauma Surg. , vol.120 , pp. 212-214
    • Pommer, A.1    Wieser, A.2    Hahn, M.P.3
  • 8
    • 0031301457 scopus 로고    scopus 로고
    • Flexible locked centromedullary osteosynthesis: Results of 125 cases of unstable cortical bone fractures of the tibia
    • [in French]
    • de la Caffiniere JY. Flexible locked centromedullary osteosynthesis: results of 125 cases of unstable cortical bone fractures of the tibia [in French]. Chirurgie. 1997;122:552-560.
    • (1997) Chirurgie , vol.122 , pp. 552-560
    • de la Caffiniere, J.Y.1
  • 9
    • 0034866953 scopus 로고    scopus 로고
    • Exchange nailing for failure of initially rodded tibial shaft fractures
    • Mercado EM, Lim EV, Stern PJ, Aquino NJ. Exchange nailing for failure of initially rodded tibial shaft fractures. Orthopedics. 2001;24:757-762.
    • (2001) Orthopedics , vol.24 , pp. 757-762
    • Mercado, E.M.1    Lim, E.V.2    Stern, P.J.3    Aquino, N.J.4
  • 11
    • 0029987640 scopus 로고    scopus 로고
    • Semiexented position of intramedullary nailing of the proximal tibia
    • Tornetta P, Collins E. Semiexented position of intramedullary nailing of the proximal tibia. Clin Orthop. 1996;328:185-189.
    • (1996) Clin. Orthop. , vol.328 , pp. 185-189
    • Tornetta, P.1    Collins, E.2
  • 12
    • 0032752892 scopus 로고    scopus 로고
    • The use of Poller screws as blocking screws in stabilising tibial fractures treated with small diameter intramedullary nails
    • Krettek C, Stephan C, Schandelmaier P, Richter M, Pape HC, Miclau T. The use of Poller screws as blocking screws in stabilising tibial fractures treated with small diameter intramedullary nails. J Bone Joint Surg Br. 1999;81:963-968.
    • (1999) J. Bone Joint Surg. Br. , vol.81 , pp. 963-968
    • Krettek, C.1    Stephan, C.2    Schandelmaier, P.3    Richter, M.4    Pape, H.C.5    Miclau, T.6
  • 13
    • 0034953216 scopus 로고    scopus 로고
    • Fractures of the proximal third of the tibial shaft treated with intramedullary nails and blocking screws
    • Ricci WM, O'Boyle M, Borrelli J, Bellabarba C, Sanders R. Fractures of the proximal third of the tibial shaft treated with intramedullary nails and blocking screws. J Orthop Trauma. 2001;15:264-270.
    • (2001) J. Orthop. Trauma , vol.15 , pp. 264-270
    • Ricci, W.M.1    O'Boyle, M.2    Borrelli, J.3    Bellabarba, C.4    Sanders, R.5
  • 14
    • 0027342530 scopus 로고
    • Influences of some design parameters on the biomechanics of the unreamed tibial intramedullary nail
    • Henley MB, Meier M, Tencer AF. Influences of some design parameters on the biomechanics of the unreamed tibial intramedullary nail. J Orthop Trauma. 1993;7:311-319.
    • (1993) J. Orthop. Trauma , vol.7 , pp. 311-319
    • Henley, M.B.1    Meier, M.2    Tencer, A.F.3
  • 15
    • 0033752683 scopus 로고    scopus 로고
    • The anterior T-frame external fixator for high-energy proximal tibial fractures
    • Bal GK, Kuo RS, Chapman JR, et al. The anterior T-frame external fixator for high-energy proximal tibial fractures. Clin Orthop. 2000;380:234-240.
    • (2000) Clin. Orthop. , vol.380 , pp. 234-240
    • Bal, G.K.1    Kuo, R.S.2    Chapman, J.R.3
  • 16
    • 0029055011 scopus 로고
    • Indirect reduction and composite fixation of extraarticular proximal tibial fractures
    • Bolhofner BR. Indirect reduction and composite fixation of extraarticular proximal tibial fractures. Clin Orthop. 1995;315:75-83.
    • (1995) Clin. Orthop. , vol.315 , pp. 75-83
    • Bolhofner, B.R.1
  • 19
    • 0034949574 scopus 로고    scopus 로고
    • Tosic external fixator in the management of proximal tibial fractures in adults
    • Tosic A, Ebraheim NA, Abou Chakra I, Emara K. Tosic external fixator in the management of proximal tibial fractures in adults. Orthopedics. 2001;24:581-584.
    • (2001) Orthopedics , vol.24 , pp. 581-584
    • Tosic, A.1    Ebraheim, N.A.2    Abou Chakra, I.3    Emara, K.4
  • 20
    • 0030730899 scopus 로고    scopus 로고
    • Extraarticular fractures of the proximal tibial diaphysis: Their epidemiology, management and outcome
    • Tytherleigh-Strong GM, Keating JF, Court-Brown CM. Extraarticular fractures of the proximal tibial diaphysis: their epidemiology, management and outcome. J R Coll Surg Edinb. 1997;42: 334-338.
    • (1997) J. R. Coll. Surg. Edinb. , vol.42 , pp. 334-338
    • Tytherleigh-Strong, G.M.1    Keating, J.F.2    Court-Brown, C.M.3
  • 21
    • 0029315767 scopus 로고
    • The use of combination internal fixation and hybrid external fixation in severe proximal tibia fractures
    • Weiner LS, Kelley M, Yang E, Steuer J, Watnick N, Evans M, Bergman M. The use of combination internal fixation and hybrid external fixation in severe proximal tibia fractures. J Orthop Trauma. 1995;9:244-250.
    • (1995) J. Orthop. Trauma , vol.9 , pp. 244-250
    • Weiner, L.S.1    Kelley, M.2    Yang, E.3    Steuer, J.4    Watnick, N.5    Evans, M.6    Bergman, M.7
  • 22
    • 0029718067 scopus 로고    scopus 로고
    • Treatment of high-energy proximal tibial fractures using the Monticelli-Spinelli external fixator: A preliminary report
    • Zecher SB, Danziger MB, Segal D, Foster T, Whitelaw GP, Covall DJ. Treatment of high-energy proximal tibial fractures using the Monticelli-Spinelli external fixator: a preliminary report. Am J Orthop. 1996;25:49-54.
    • (1996) Am. J. Orthop. , vol.25 , pp. 49-54
    • Zecher, S.B.1    Danziger, M.B.2    Segal, D.3    Foster, T.4    Whitelaw, G.P.5    Covall, D.J.6
  • 23
    • 0034823155 scopus 로고    scopus 로고
    • A minimally invasive medial approach for proximal tibial fractures
    • Krettek C, Gerich T, Miclau T. A minimally invasive medial approach for proximal tibial fractures. Injury. 2001;32(suppl 1): SA4-SA13.
    • (2001) Injury , vol.32 , Issue.SUPPL. 1
    • Krettek, C.1    Gerich, T.2    Miclau, T.3
  • 24
    • 0033994252 scopus 로고    scopus 로고
    • The use of interlocked 'customised' blade plates in the treatment of metaphyseal fractures in patients with poor bone stock
    • Palmer SH, Handley R, Willett K. The use of interlocked 'customised' blade plates in the treatment of metaphyseal fractures in patients with poor bone stock. Injury. 2000;31:187-191.
    • (2000) Injury , vol.31 , pp. 187-191
    • Palmer, S.H.1    Handley, R.2    Willett, K.3
  • 25
    • 0036140839 scopus 로고    scopus 로고
    • Anatomic assessment of the proper insertion site for a tibial intramedullary nail
    • Samuelson MA, McPherson EJ, Norris L. Anatomic assessment of the proper insertion site for a tibial intramedullary nail. J Orthop Trauma. 2002;16:23-25.
    • (2002) J. Orthop. Trauma , vol.16 , pp. 23-25
    • Samuelson, M.A.1    McPherson, E.J.2    Norris, L.3
  • 26
    • 0026814928 scopus 로고
    • Incidence and causes of malalignment following tibial intramedullary nailing
    • [in German]
    • Ahlers J, von Issendorff WD. Incidence and causes of malalignment following tibial intramedullary nailing [in German]. Unfallchirurgie. 1992;18:31-36.
    • (1992) Unfallchirurgie , vol.18 , pp. 31-36
    • Ahlers, J.1    von Issendorff, W.D.2
  • 27
    • 0030209109 scopus 로고    scopus 로고
    • Biomechanics of rigid tibial nail insertion sites
    • Carr JB, Sobba DB, Bear LL. Biomechanics of rigid tibial nail insertion sites. Am J Orthop. 1996;25:553-556.
    • (1996) Am. J. Orthop. , vol.25 , pp. 553-556
    • Carr, J.B.1    Sobba, D.B.2    Bear, L.L.3
  • 28
    • 0035085281 scopus 로고    scopus 로고
    • The nail-insertion point in unreamed tibial nailing and its influence on the axial malalignment in proximal tibial fractures
    • Lembcke O, Ruter A, Beck A. The nail-insertion point in unreamed tibial nailing and its influence on the axial malalignment in proximal tibial fractures. Arch Orthop Trauma Surg. 2001;121: 197-200.
    • (2001) Arch. Orthop. Trauma Surg. , vol.121 , pp. 197-200
    • Lembcke, O.1    Ruter, A.2    Beck, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.