Multimodality monitoring of transcranial electric motor and somatosensory-evoked potentials during surgical correction of spinal deformity in patients with cerebral palsy and other neuromuscular disorders

Author keywords

Neuromuscular scoliosis; Somatosensory evoked potential; Transcranial electric motor evoked potential

Indexed keywords

ADOLESCENT; ADULT; ARTICLE; CEREBRAL PALSY; CHILD; CONTROLLED STUDY; ELECTRIC POTENTIAL; EVOKED MUSCLE RESPONSE; EVOKED SOMATOSENSORY RESPONSE; EVOKED SPINAL CORD RESPONSE; FEMALE; HUMAN; MAJOR CLINICAL STUDY; MALE; NEUROMUSCULAR DISEASE; PATIENT MONITORING; POSTERIOR TIBIAL NERVE; PRIORITY JOURNAL; PROSPECTIVE STUDY; RELIABILITY; SCOLIOSIS; SPINE FUSION; SPINE MALFORMATION; TRANSCRANIAL ELECTRIC MOTOR EVOKED POTENTIAL;

EID: 0042975332     PISSN: 03622436     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.BRS.0000083202.62956.A8     Document Type: Article
Times cited : (101)

References (25)
  • 1
    • 0032006775 scopus 로고    scopus 로고
    • Major intraoperative neurologic deficits in pediatric and adult spinal deformity patients. Incidence and etiology at one institution
    • Bridwell KH, Lenke LG, Baldus C, et al. Major intraoperative neurologic deficits in pediatric and adult spinal deformity patients. Incidence and etiology at one institution. Spine 1998;23:324-31.
    • (1998) Spine , vol.23 , pp. 324-331
    • Bridwell, K.H.1    Lenke, L.G.2    Baldus, C.3
  • 2
    • 0026201342 scopus 로고
    • Spinal cord monitoring. Results of the Scoliosis Research Society and the European Spinal Deformity Society Survey
    • Dawson EG, Sherman JE, Kanim LE, et al. Spinal cord monitoring. Results of the Scoliosis Research Society and the European Spinal Deformity Society Survey. Spine 1991;16:S361-4.
    • (1991) Spine , vol.16
    • Dawson, E.G.1    Sherman, J.E.2    Kanim, L.E.3
  • 5
    • 0019944193 scopus 로고
    • Segmental spinal instrumentation: A preliminary report of 40 consecutive cases
    • Herring JA, Wenger DR. Segmental spinal instrumentation: a preliminary report of 40 consecutive cases. Spine 1982;7:285-98.
    • (1982) Spine , vol.7 , pp. 285-298
    • Herring, J.A.1    Wenger, D.R.2
  • 6
    • 0028881660 scopus 로고
    • Somatosensory evoked potential spinal cord monitoring reduces neurologic deficits after scoliosis surgery: Results of a large multicenter survey
    • Nuwer MR, Dawson EG, Carlson LG, et al. Somatosensory evoked potential spinal cord monitoring reduces neurologic deficits after scoliosis surgery: results of a large multicenter survey. Electroencephalogr Clin Neurophysiol 1995;96:6-11.
    • (1995) Electroencephalogr Clin Neurophysiol , vol.96 , pp. 6-11
    • Nuwer, M.R.1    Dawson, E.G.2    Carlson, L.G.3
  • 7
    • 0032796634 scopus 로고    scopus 로고
    • Spinal cord monitoring: Current state of the art
    • Padberg AM, Bridwell KH. Spinal cord monitoring: current state of the art. Orthop Clin North Am 1999;30:407-33.
    • (1999) Orthop Clin North Am , vol.30 , pp. 407-433
    • Padberg, A.M.1    Bridwell, K.H.2
  • 8
    • 0030793623 scopus 로고    scopus 로고
    • Neurophysiological monitoring during scoliosis surgery: A multimodality approach
    • Schwartz DM, Drummond DS, Schwartz JA, et al. Neurophysiological monitoring during scoliosis surgery: a multimodality approach. Semin Spine Surg 1997;9:97-111.
    • (1997) Semin Spine Surg , vol.9 , pp. 97-111
    • Schwartz, D.M.1    Drummond, D.S.2    Schwartz, J.A.3
  • 9
    • 0041591549 scopus 로고    scopus 로고
    • Neurological injury complicating surgery for spinal deformity: Etiology, prevention and treatment
    • DeWald R, ed. New York, NY: Thieme Medical Publishers, Inc
    • Drummond DS, Schwartz DM, Johnston DR, et al. Neurological injury complicating surgery for spinal deformity: etiology, prevention and treatment. In: DeWald R, ed. Fundamentals of Spine Surgery: A Core Curriculum. New York, NY: Thieme Medical Publishers, Inc; 2002.
    • (2002) Fundamentals of Spine Surgery: A Core Curriculum
    • Drummond, D.S.1    Schwartz, D.M.2    Johnston, D.R.3
  • 10
    • 0027304346 scopus 로고
    • Efficacy of spinal cord monitoring in neuromuscular scoliosis
    • Ashkenaze D, Mudiyam R, Boachie-Adjei O, et al. Efficacy of spinal cord monitoring in neuromuscular scoliosis. Spine 1993;18:1627-33.
    • (1993) Spine , vol.18 , pp. 1627-1633
    • Ashkenaze, D.1    Mudiyam, R.2    Boachie-Adjei, O.3
  • 11
    • 0029990563 scopus 로고    scopus 로고
    • Efficacy of spinal cord monitoring in scoliosis surgery in patients with cerebral palsy
    • Ecker ML, Dormans JP, Schwartz, DM, et al. Efficacy of spinal cord monitoring in scoliosis surgery in patients with cerebral palsy. J Spinal Disord 1996;9:159-64.
    • (1996) J Spinal Disord , vol.9 , pp. 159-164
    • Ecker, M.L.1    Dormans, J.P.2    Schwartz, D.M.3
  • 12
    • 0029060858 scopus 로고
    • Efficacy of multimodality spinal cord monitoring during surgery for neuromuscular scoliosis
    • Owen JH, Sponseller PD, Szymanski J, et al. Efficacy of multimodality spinal cord monitoring during surgery for neuromuscular scoliosis. Spine 1995;20: 1480-8.
    • (1995) Spine , vol.20 , pp. 1480-1488
    • Owen, J.H.1    Sponseller, P.D.2    Szymanski, J.3
  • 13
    • 0029997782 scopus 로고    scopus 로고
    • Validity and reliability of spinal cord monitoring in neuromuscular spinal deformity surgery
    • Padberg AM, Russo MH, Lenke LG, et al. Validity and reliability of spinal cord monitoring in neuromuscular spinal deformity surgery. J Spinal Disord 1996;9:150-8.
    • (1996) J Spinal Disord , vol.9 , pp. 150-158
    • Padberg, A.M.1    Russo, M.H.2    Lenke, L.G.3
  • 14
    • 0031669964 scopus 로고    scopus 로고
    • Neurophysiological identification of iatrogenic neural injury during complex spine surgery
    • Schwartz DM, Sestokas AK, Turner LA, et al. Neurophysiological identification of iatrogenic neural injury during complex spine surgery. Semin Spine Surg 1998;10:242-51.
    • (1998) Semin Spine Surg , vol.10 , pp. 242-251
    • Schwartz, D.M.1    Sestokas, A.K.2    Turner, L.A.3
  • 15
    • 0034789485 scopus 로고    scopus 로고
    • A new application of TCE-MEP: Spinal cord monitoring in patients with severe neuromuscular weakness undergoing corrective spine surgery
    • Langeloo DD, Journee HL, Polak B, et al. A new application of TCE-MEP: spinal cord monitoring in patients with severe neuromuscular weakness undergoing corrective spine surgery. J Spinal Disord 2001;14:445-8.
    • (2001) J Spinal Disord , vol.14 , pp. 445-448
    • Langeloo, D.D.1    Journee, H.L.2    Polak, B.3
  • 16
    • 0033508659 scopus 로고    scopus 로고
    • Factors predicting postoperative complications following spinal fusions in children with cerebral palsy
    • Lipton GE, Miller F, Dabney KW, et al. Factors predicting postoperative complications following spinal fusions in children with cerebral palsy. J Spinal Disord 1999;12:197-205.
    • (1999) J Spinal Disord , vol.12 , pp. 197-205
    • Lipton, G.E.1    Miller, F.2    Dabney, K.W.3
  • 17
    • 0031053289 scopus 로고    scopus 로고
    • Influence of nitrous oxide on posterior tibial nerve cortical somatosensory evoked potentials
    • Schwartz DM, Schwartz JA, Pratt RE Jr, et al. Influence of nitrous oxide on posterior tibial nerve cortical somatosensory evoked potentials. J Spinal Disord 1997;10:80-6.
    • (1997) J Spinal Disord , vol.10 , pp. 80-86
    • Schwartz, D.M.1    Schwartz, J.A.2    Pratt R.E., Jr.3
  • 18
    • 0011444428 scopus 로고    scopus 로고
    • Intraoperative neurophysiological monitoring during cervical spine surgery
    • Schwartz DM. Intraoperative neurophysiological monitoring during cervical spine surgery. Oper Tech Orthop 1996;6:6-12.
    • (1996) Oper Tech Orthop , vol.6 , pp. 6-12
    • Schwartz, D.M.1
  • 19
    • 0034586201 scopus 로고    scopus 로고
    • Prevention of positional brachial plexopathy during surgical correction of scoliosis
    • Schwartz DM, Drummond DS, Hahn M, et al. Prevention of positional brachial plexopathy during surgical correction of scoliosis. J Spinal Disord 2000;13:178-82.
    • (2000) J Spinal Disord , vol.13 , pp. 178-182
    • Schwartz, D.M.1    Drummond, D.S.2    Hahn, M.3
  • 20
    • 0034927906 scopus 로고    scopus 로고
    • The 'motor' inaccuracy in neurogenic motor evoked potentials
    • Deletis V. The 'motor' inaccuracy in neurogenic motor evoked potentials. Clin Neurophysiol 2001;112:1365-6.
    • (2001) Clin Neurophysiol , vol.112 , pp. 1365-1366
    • Deletis, V.1
  • 21
    • 0000405680 scopus 로고    scopus 로고
    • Intraoperative collision studies demonstrate descending spinal cord stimulated evoked potentials and ascending somatosensory evoked potentials are mediated through common pathways
    • Leppanen R, Madigan R, Sears C, et al. Intraoperative collision studies demonstrate descending spinal cord stimulated evoked potentials and ascending somatosensory evoked potentials are mediated through common pathways. J Clin Neurophysiol 1999;16:170.
    • (1999) J Clin Neurophysiol , vol.16 , pp. 170
    • Leppanen, R.1    Madigan, R.2    Sears, C.3
  • 22
    • 0034927909 scopus 로고    scopus 로고
    • Anterior spinal cord injury with preserved neurogenic 'motor' evoked potentials
    • Minahan RE, Sepkuty JP, Lesser RP, et al. Anterior spinal cord injury with preserved neurogenic 'motor' evoked potentials. Clin Neurophysiol 2001; 112:1442-50.
    • (2001) Clin Neurophysiol , vol.112 , pp. 1442-1450
    • Minahan, R.E.1    Sepkuty, J.P.2    Lesser, R.P.3
  • 23
    • 0034177676 scopus 로고    scopus 로고
    • Spinally elicited peripheral nerve responses are sensory rather than motor
    • Toleikis JR, Skelly JP, Carlvin AO, et al. Spinally elicited peripheral nerve responses are sensory rather than motor. Clin Neurophysiol 2000;111:736-42.
    • (2000) Clin Neurophysiol , vol.111 , pp. 736-742
    • Toleikis, J.R.1    Skelly, J.P.2    Carlvin, A.O.3
  • 24
    • 0030255082 scopus 로고    scopus 로고
    • Influence of rigid spinal instrumentation on the neurogenic motor evoked potential
    • Schwartz DM, Drummond DS, Ecker ML. Influence of rigid spinal instrumentation on the neurogenic motor evoked potential. J Spinal Disord 1996; 9:439-45.
    • (1996) J Spinal Disord , vol.9 , pp. 439-445
    • Schwartz, D.M.1    Drummond, D.S.2    Ecker, M.L.3
  • 25
    • 0024459072 scopus 로고
    • Variability of somarosensory cortical evoked potential monitoring during spinal surgery
    • Lubicky JP, Spadaro JA, Yuan HA, et al. Variability of somarosensory cortical evoked potential monitoring during spinal surgery. Spine 1989;14: 790-8.
    • (1989) Spine , vol.14 , pp. 790-798
    • Lubicky, J.P.1    Spadaro, J.A.2    Yuan, H.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.