Volumn 228, Issue 3, 2003, Pages 895-900

Brachial artery: Measurement of flow-mediated dilatation with cross-sectional US - Technical validation

Author keywords

Arteries, extremities; Arteries, US; Blood, flow dynamics; Computers; Phantoms

Indexed keywords

ALGORITHM; APPARATUS; ARTERY BLOOD FLOW; ARTERY DILATATION; ARTICLE; AUTOANALYSIS; BRACHIAL ARTERY; ECHOGRAPHY; HUMAN; HUMAN EXPERIMENT; HYPEREMIA; IMAGE ANALYSIS; IMAGE DISPLAY; IMAGE PROCESSING; IMAGE RECONSTRUCTION; NORMAL HUMAN; PHANTOM; VALIDATION PROCESS; VOLUNTEER;

EID: 0042931338     PISSN: 00338419     EISSN: None     Source Type: Journal    
DOI: 10.1148/radiol.2283020966     Document Type: Article
Times cited : (20)

References (21)
  • 1
    • 0019195506 scopus 로고
    • The obligatory role of endothelial cells in the relaxation of arterial smooth muscle by acetylcholine
    • Furchgott RF, Zawadzki JV. The obligatory role of endothelial cells in the relaxation of arterial smooth muscle by acetylcholine. Nature 1980; 288:373-376.
    • (1980) Nature , vol.288 , pp. 373-376
    • Furchgott, R.F.1    Zawadzki, J.V.2
  • 2
    • 0029972540 scopus 로고    scopus 로고
    • Endothelium and inelastic arteries: An early marker of vascular dysfunction in noninsulin dependent diabetes
    • Goodfellow J, Ramsey MW, Luddington LA, et al. Endothelium and inelastic arteries: an early marker of vascular dysfunction in noninsulin dependent diabetes. BMJ 1996; 312: 744-745.
    • (1996) BMJ , vol.312 , pp. 744-745
    • Goodfellow, J.1    Ramsey, M.W.2    Luddington, L.A.3
  • 3
    • 0028957394 scopus 로고
    • Nitric oxide is responsible for flow-dependent dilatation of human peripheral conduit arteries in vivo
    • Joannides R, Haefeli WE, Linder L, et al. Nitric oxide is responsible for flow-dependent dilatation of human peripheral conduit arteries in vivo. Circulation 1995; 91:1314-1319.
    • (1995) Circulation , vol.91 , pp. 1314-1319
    • Joannides, R.1    Haefeli, W.E.2    Linder, L.3
  • 6
    • 0026478022 scopus 로고
    • Non-invasive detection of endothelial dysfunction in children and adults at risk of atherosclerosis
    • Celermajer DS, Sorensen KE, Gooch VM, et al. Non-invasive detection of endothelial dysfunction in children and adults at risk of atherosclerosis. Lancet 1992; 340:1111-1115.
    • (1992) Lancet , vol.340 , pp. 1111-1115
    • Celermajer, D.S.1    Sorensen, K.E.2    Gooch, V.M.3
  • 7
    • 0027990857 scopus 로고
    • Aging is associated with endothelial dysfunction in healthy men years before the age-related decline in women
    • Celermajer DS, Sorensen KE, Spiegelhalter DJ, et al. Aging is associated with endothelial dysfunction in healthy men years before the age-related decline in women. J Am Coll Cardiol 1994; 24:471-476.
    • (1994) J Am Coll Cardiol , vol.24 , pp. 471-476
    • Celermajer, D.S.1    Sorensen, K.E.2    Spiegelhalter, D.J.3
  • 8
    • 0028929772 scopus 로고
    • Technical aspects of evaluating brachial artery vasodilatation using high-frequency ultrasound
    • Corretti MC, Plotnick GD, Vogel RA. Technical aspects of evaluating brachial artery vasodilatation using high-frequency ultrasound. Am J Physiol 1995; 268(4 pt 2):H1397-H1404.
    • (1995) Am J Physiol , vol.268 , Issue.4 PART 2
    • Corretti, M.C.1    Plotnick, G.D.2    Vogel, R.A.3
  • 9
    • 0037116573 scopus 로고    scopus 로고
    • Guidelines for the ultrasound assessment of endothelial-dependent flow-mediated vasodilation of the brachial artery: A report of the International Brachial Artery Reactivity Task Force
    • Corretti MC, Anderson TJ, Benjamin EJ, et al. Guidelines for the ultrasound assessment of endothelial-dependent flow-mediated vasodilation of the brachial artery: a report of the International Brachial Artery Reactivity Task Force. J Am Coll Cardiol 2002; 39:257-265.
    • (2002) J Am Coll Cardiol , vol.39 , pp. 257-265
    • Corretti, M.C.1    Anderson, T.J.2    Benjamin, E.J.3
  • 10
    • 0030024151 scopus 로고    scopus 로고
    • Passive smoking and impaired endothelium-dependent arterial dilatation in healthy young adults
    • Celermajer DS, Adams MR, Clarkson P, et al. Passive smoking and impaired endothelium-dependent arterial dilatation in healthy young adults. N Engl J Med 1996; 334:150-154.
    • (1996) N Engl J Med , vol.334 , pp. 150-154
    • Celermajer, D.S.1    Adams, M.R.2    Clarkson, P.3
  • 11
    • 0021997026 scopus 로고
    • Assessment of short-, medium-, and long-term variations in arterial dimensions from computer-assisted quantitation of coronary cineangiograms
    • Reiber JH, Serruys PW, Kooijman CJ, et al. Assessment of short-, medium-, and long-term variations in arterial dimensions from computer-assisted quantitation of coronary cineangiograms. Circulation 1985; 71:280-288.
    • (1985) Circulation , vol.71 , pp. 280-288
    • Reiber, J.H.1    Serruys, P.W.2    Kooijman, C.J.3
  • 12
    • 0035205180 scopus 로고    scopus 로고
    • The relationship between vascular wall shear stress and flow mediated dilation: Endothelial function assessed by phase contrast magnetic resonance angiography
    • Silber HA, Bluemke DA, Ouyang P, Du YP, Post WS, Lima JA. The relationship between vascular wall shear stress and flow mediated dilation: endothelial function assessed by phase contrast magnetic resonance angiography. J Am Coll Cardiol 2001; 38:1859-1865.
    • (2001) J Am Coll Cardiol , vol.38 , pp. 1859-1865
    • Silber, H.A.1    Bluemke, D.A.2    Ouyang, P.3    Du, Y.P.4    Post, W.S.5    Lima, J.A.6
  • 13
    • 0032076706 scopus 로고    scopus 로고
    • Measurement of the time course of peripheral vasoactivity: Results in cigarette smokers
    • Stadler RW, Ibrahim SF, Lees RS. Measurement of the time course of peripheral vasoactivity: results in cigarette smokers. Atherosclerosis 1998; 138:197-205.
    • (1998) Atherosclerosis , vol.138 , pp. 197-205
    • Stadler, R.W.1    Ibrahim, S.F.2    Lees, R.S.3
  • 14
    • 0030026742 scopus 로고    scopus 로고
    • New methods for arterial diameter measurement from B-mode images
    • Stadler RW, Karl WC, Lees RS. New methods for arterial diameter measurement from B-mode images. Ultrasound Med Biol 1996; 22: 25-34.
    • (1996) Ultrasound Med Biol , vol.22 , pp. 25-34
    • Stadler, R.W.1    Karl, W.C.2    Lees, R.S.3
  • 15
    • 0026772603 scopus 로고
    • Reproducibility of noninvasive ultrasound measurement of carotid atherosclerosis: The Asymptomatic Carotid Artery Plaque Study
    • Riley WA, Barnes RW, Applegate WB, et al. Reproducibility of noninvasive ultrasound measurement of carotid atherosclerosis: the Asymptomatic Carotid Artery Plaque Study. Stroke 1992; 23:1062-1068.
    • (1992) Stroke , vol.23 , pp. 1062-1068
    • Riley, W.A.1    Barnes, R.W.2    Applegate, W.B.3
  • 16
    • 0027995413 scopus 로고
    • Evaluation of computerized edge tracking for quantifying intima-media thickness of the common carotid artery from B-mode ultrasound images
    • Selzer RH, Hodis HN, Helenann K, Mack WJ, Lee PL. Evaluation of computerized edge tracking for quantifying intima-media thickness of the common carotid artery from B-mode ultrasound images. Atherosclerosis 1994; 111:1-11.
    • (1994) Atherosclerosis , vol.111 , pp. 1-11
    • Selzer, R.H.1    Hodis, H.N.2    Helenann, K.3    Mack, W.J.4    Lee, P.L.5
  • 17
    • 0036826355 scopus 로고    scopus 로고
    • Automated analysis of brachial ultrasound image sequences: Early detection of cardiovascular disease via surrogates of endothelial function
    • Sonka M, Liang W, Lauer RM. Automated analysis of brachial ultrasound image sequences: early detection of cardiovascular disease via surrogates of endothelial function. IEEE Trans Med Imaging 2002; 21:1271-1279.
    • (2002) IEEE Trans Med Imaging , vol.21 , pp. 1271-1279
    • Sonka, M.1    Liang, W.2    Lauer, R.M.3
  • 18
    • 0029117715 scopus 로고
    • Non-invasive measurement of human endothelium dependent arterial responses: Accuracy and reproducibility
    • Sorensen KE, Celermajer DS, Spiegelhalter DJ, et al. Non-invasive measurement of human endothelium dependent arterial responses: accuracy and reproducibility. Br Heart J 1995; 74:247-253.
    • (1995) Br Heart J , vol.74 , pp. 247-253
    • Sorensen, K.E.1    Celermajer, D.S.2    Spiegelhalter, D.J.3
  • 20
    • 0002349614 scopus 로고
    • Algorithm for computer control of a digital plotter
    • Bresenham JE. Algorithm for computer control of a digital plotter. IBM Syst J 1965; 4:25-30.
    • (1965) IBM Syst J , vol.4 , pp. 25-30
    • Bresenham, J.E.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.