메뉴 건너뛰기




Volumn 50, Issue 4 II, 2003, Pages 842-846

Xenon-neon gas proportional-scintillation counters for X-rays below 2 keV: Experimental results

Author keywords

Noble gas detectors; Soft x rays; Spectra distortion

Indexed keywords

ATMOSPHERIC PRESSURE; COMPUTER SIMULATION; ELECTRONS; GAS DETECTORS; MONTE CARLO METHODS; SCINTILLATION COUNTERS;

EID: 0042928209     PISSN: 00189499     EISSN: None     Source Type: Journal    
DOI: 10.1109/TNS.2003.815117     Document Type: Conference Paper
Times cited : (15)

References (15)
  • 2
    • 0037597168 scopus 로고
    • Properties of gas scintillation proportional counters for soft X-rays
    • H. Inoue, K. Koyama, M. Matsuoka, T. Ohashi, and Y. Tanaka, "Properties of gas scintillation proportional counters for soft X-rays," Nucl. Instrum. Methods, vol. 157, pp. 295-300, 1978.
    • (1978) Nucl. Instrum. Methods , vol.157 , pp. 295-300
    • Inoue, H.1    Koyama, K.2    Matsuoka, M.3    Ohashi, T.4    Tanaka, Y.5
  • 3
    • 0018435641 scopus 로고
    • A high resolution gas scintillation proportional counter for studying low energy cosmic X-ray sources
    • Feb.
    • T. T. Hamilton, C. J. Hailey, W. H.-M. Ku, and R. Novick, "A high resolution gas scintillation proportional counter for studying low energy cosmic X-ray sources," IEEE Trans. Nucl. Sci., vol. NS-27, pp. 190-195, Feb. 1980.
    • (1980) IEEE Trans. Nucl. Sci. , vol.NS-27 , pp. 190-195
    • Hamilton, T.T.1    Hailey, C.J.2    Ku, W.H.-M.3    Novick, R.4
  • 4
    • 0024656431 scopus 로고
    • Soft X-ray energy resolution and background rejection in a driftless GPSC
    • D. G. Simons and P. A. J. de Korte, "Soft X-ray energy resolution and background rejection in a driftless GPSC," Nucl. Instrum. Methods, vol. A9277, pp. 642-656, 1989.
    • (1989) Nucl. Instrum. Methods , vol.A9277 , pp. 642-656
    • Simons, D.G.1    De Korte, P.A.J.2
  • 5
    • 0000413148 scopus 로고
    • Distortion effects in soft-X-ray energy spectra for xenon gaseous detectors: A Monte Carlo simulation study
    • T. H. V. T. Dias, F. P. Santos, A. D. Stauffer, and C. A. N. Conde, "Distortion effects in soft-X-ray energy spectra for xenon gaseous detectors: A Monte Carlo simulation study," Phys. Rev. A, vol. 46, pp. 237-245, 1992.
    • (1992) Phys. Rev. A , vol.46 , pp. 237-245
    • Dias, T.H.V.T.1    Santos, F.P.2    Stauffer, A.D.3    Conde, C.A.N.4
  • 6
    • 0029358531 scopus 로고
    • Pulse-height-spectrum distortion in xenon gaseous detectors for soft X-rays: Experimental results
    • Aug.
    • F. P. Santos, J. M. F. dos Santos, T. H. V. T. Dias, and C. A. N. Conde, "Pulse-height-spectrum distortion in xenon gaseous detectors for soft X-rays: Experimental results," IEEE Trans. Nucl. Sci., vol. 42, pp. 611-614, Aug. 1995.
    • (1995) IEEE Trans. Nucl. Sci. , vol.42 , pp. 611-614
    • Santos, F.P.1    Dos Santos, J.M.F.2    Dias, T.H.V.T.3    Conde, C.A.N.4
  • 9
    • 0042319572 scopus 로고    scopus 로고
    • Personal Comunication, Phys. Dept., Rikkyo Univ., Tokyo, Japan
    • S. Kubota, Personal Comunication, Phys. Dept., Rikkyo Univ., Tokyo, Japan, 1999.
    • (1999)
    • Kubota, S.1
  • 13
    • 0035875214 scopus 로고    scopus 로고
    • Monte Carlo simulation study of the Fano factor, w value, and energy resolution for the absorption of soft X-rays in xenon-neon gas mixtures
    • F. P. Santos, T. H. V. T. Dias, P. J. B. M. Rachinhas, C. A. N. Conde, and A. D. Stauffer, "Monte Carlo simulation study of the Fano factor, w value, and energy resolution for the absorption of soft X-rays in xenon-neon gas mixtures," J. Appl. Phys., vol. 89, pp. 8202-8213, 2001.
    • (2001) J. Appl. Phys. , vol.89 , pp. 8202-8213
    • Santos, F.P.1    Dias, T.H.V.T.2    Rachinhas, P.J.B.M.3    Conde, C.A.N.4    Stauffer, A.D.5
  • 14
    • 0042319571 scopus 로고    scopus 로고
    • Electroluminescence yield for λ > 165 nm in neon-xenon mixtures: Experimental results
    • June
    • F. I. G. M. Borges, J. M. F. dos Santos, S. Kubota, and C. A. N. Conde, "Electroluminescence yield for λ > 165 nm in neon-xenon mixtures: Experimental results," IEEE Trans. Nucl. Sci., vol. 44, pp. 464-467, June 1997.
    • (1997) IEEE Trans. Nucl. Sci. , vol.44 , pp. 464-467
    • Borges, F.I.G.M.1    Dos Santos, J.M.F.2    Kubota, S.3    Conde, C.A.N.4
  • 15
    • 0038694595 scopus 로고    scopus 로고
    • An investigation of the M-discontinuities in the response of xenon gas detectors to X-rays in the 0.1 to 2 keV range
    • to be published
    • F. I. G. M. Borges, T. H. V. Dias, F. P. Santos, P. J. B. M. Rachinhas, J. M. F. dos Santos, and C. A. N. Conde, "An investigation of the M-discontinuities in the response of xenon gas detectors to X-rays in the 0.1 to 2 keV range," Nucl. Instrum. Methods A, vol. 505, pp. 242-246, 2002, to be published.
    • (2002) Nucl. Instrum. Methods A , vol.505 , pp. 242-246
    • Borges, F.I.G.M.1    Dias, T.H.V.2    Santos, F.P.3    Rachinhas, P.J.B.M.4    Dos Santos, J.M.F.5    Conde, C.A.N.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.