Volumn 19, Issue 4, 2003, Pages 1501-1509

Attenuation correction of PET activation studies in the presence of task-related motion

Author keywords

Attenuation correction; Mismatch transmission emission scan; Motion

Indexed keywords

ACCURACY; ANALYTICAL ERROR; ARTICLE; ATTENUATION; BRAIN FUNCTION; CALCULATION; CLINICAL ARTICLE; CONTROLLED STUDY; FEMALE; HUMAN; PHANTOM; POSITRON EMISSION TOMOGRAPHY; QUANTITATIVE ANALYSIS; SIGNAL NOISE RATIO; VISUAL STIMULATION;

EID: 0042926484     PISSN: 10538119     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1053-8119(03)00216-7     Document Type: Article
Times cited : (21)

References (26)
  • 1
    • 0001171133 scopus 로고    scopus 로고
    • Performance evaluation of the whole-body PET scanner ECAT EXACT HR+ following the IEC standard
    • Adam L.E., Zaers J., Ostertag H., Trojan H., Bellemann M.E., Brix G. Performance evaluation of the whole-body PET scanner ECAT EXACT HR+ following the IEC standard. IEEE Trans. Nucl. Sci. 44:1997;1172-1179.
    • (1997) IEEE Trans. Nucl. Sci. , vol.44 , pp. 1172-1179
    • Adam, L.E.1    Zaers, J.2    Ostertag, H.3    Trojan, H.4    Bellemann, M.E.5    Brix, G.6
  • 2
    • 0031804898 scopus 로고    scopus 로고
    • How to obtain high-accuracy image registration: Application to movement correction of dynamic positron emission tomography data
    • Andersson J.L. How to obtain high-accuracy image registration application to movement correction of dynamic positron emission tomography data . Eur. J. Nucl. Med. 25:1998;575-586.
    • (1998) Eur. J. Nucl. Med. , vol.25 , pp. 575-586
    • Andersson, J.L.1
  • 3
    • 0028947673 scopus 로고
    • Accurate attenuation correction despite movement during PET imaging
    • Andersson J.L., Vagnhammar B.E., Schneider H. Accurate attenuation correction despite movement during PET imaging. J. Nucl. Med. 36:1995;670-678.
    • (1995) J. Nucl. Med. , vol.36 , pp. 670-678
    • Andersson, J.L.1    Vagnhammar, B.E.2    Schneider, H.3
  • 5
    • 0023243756 scopus 로고
    • Improved SPECT using simultaneous emission and transmission tomography
    • Bailey D.L., Hutton B.F., Walker P.J. Improved SPECT using simultaneous emission and transmission tomography. J. Nucl. Med. 28:1987;844-851.
    • (1987) J. Nucl. Med. , vol.28 , pp. 844-851
    • Bailey, D.L.1    Hutton, B.F.2    Walker, P.J.3
  • 6
    • 0020048935 scopus 로고
    • Determination of object contour from projections for attenuation correction in cranial positron emission tomography
    • Bergstrom M., Litton J., Eriksson L., Bohm C., Blomqvist G. Determination of object contour from projections for attenuation correction in cranial positron emission tomography. J. Comput. Assist. Tomogr. 6:1982;365-372.
    • (1982) J. Comput. Assist. Tomogr. , vol.6 , pp. 365-372
    • Bergstrom, M.1    Litton, J.2    Eriksson, L.3    Bohm, C.4    Blomqvist, G.5
  • 7
    • 0027514339 scopus 로고
    • A procedure for patient repositioning and compensation for misalignment between transmission and emission data in PET heart studies
    • Bettinardi V., Gilardi M.C., Lucignani G., Landoni C., Rizzo G., Striano G., Fazio F. A procedure for patient repositioning and compensation for misalignment between transmission and emission data in PET heart studies. J. Nucl. Med. 34:1993;137-142.
    • (1993) J. Nucl. Med. , vol.34 , pp. 137-142
    • Bettinardi, V.1    Gilardi, M.C.2    Lucignani, G.3    Landoni, C.4    Rizzo, G.5    Striano, G.6    Fazio, F.7
  • 8
    • 0042670867 scopus 로고    scopus 로고
    • Strategies for improving the quantitative accuracy of post-injection transmission scans in cardiac PET
    • Boellaard R., van der Weerdt A.P., Knaapen P., Visser F.C., Lammertsma A.A. Strategies for improving the quantitative accuracy of post-injection transmission scans in cardiac PET. J. Nucl. Med. 42:(Suppl. S):2001;842.
    • (2001) J. Nucl. Med. , vol.42 , Issue.SUPPL. S , pp. 842
    • Boellaard, R.1    Van der Weerdt, A.P.2    Knaapen, P.3    Visser, F.C.4    Lammertsma, A.A.5
  • 9
    • 0029811098 scopus 로고    scopus 로고
    • Realignment of emission contaminated attenuation maps with uncontaminated attenuation maps for attenuation correction in PET
    • Buvat I., Freedman N.M., Dilsizian V., Bacharach S.L. Realignment of emission contaminated attenuation maps with uncontaminated attenuation maps for attenuation correction in PET. J. Comput. Assist. Tomogr. 20:1996;848-854.
    • (1996) J. Comput. Assist. Tomogr. , vol.20 , pp. 848-854
    • Buvat, I.1    Freedman, N.M.2    Dilsizian, V.3    Bacharach, S.L.4
  • 11
    • 0026635781 scopus 로고
    • Misalignment between PET transmission and emission scans: Effect on myocardial imaging
    • Misalignment between PET transmission and emission scans effect on myocardial imaging . J. Nucl. Med. 33:1992;1214-1215.
    • (1992) J. Nucl. Med , vol.33 , pp. 1214-1215
  • 13
    • 0032177617 scopus 로고    scopus 로고
    • Automatic registration of pelvic computed tomography data and magnetic resonance scans including a dull circle method for quantitative accuracy evaluation
    • Herk van M., Munck J.C., Lebesque J.V., Muller S., Rasch C., Touw A. Automatic registration of pelvic computed tomography data and magnetic resonance scans including a dull circle method for quantitative accuracy evaluation. Med. Phys. 25:1998;2054-2067.
    • (1998) Med. Phys. , vol.25 , pp. 2054-2067
    • Herk van, M.1    Munck, J.C.2    Lebesque, J.V.3    Muller, S.4    Rasch, C.5    Touw, A.6
  • 14
    • 85031071640 scopus 로고    scopus 로고
    • An image registration method to correct emission-transmission scan mismatch due to task-related motion in PET activation studies
    • Heuvel van den O.A., Boellaard R., Veltman D.J., Mesina C.T., Lammertsma A.A. An image registration method to correct emission-transmission scan mismatch due to task-related motion in PET activation studies. J. Nucl. Med. 43:(Suppl):2002;101P.
    • (2002) J. Nucl. Med. , vol.43 , Issue.SUPPL.
    • Heuvel van den, O.A.1    Boellaard, R.2    Veltman, D.J.3    Mesina, C.T.4    Lammertsma, A.A.5
  • 15
    • 0018667264 scopus 로고
    • Quantitation in positron emission computed tomography. II. Effects of inaccurate attenuation correction
    • Huang S.C., Hoffman E.J., Phelps M.E., Kuhl D.E. Quantitation in positron emission computed tomography. II. Effects of inaccurate attenuation correction. J. Comput. Assist. Tomogr. 3:1979;804-814.
    • (1979) J. Comput. Assist. Tomogr. , vol.3 , pp. 804-814
    • Huang, S.C.1    Hoffman, E.J.2    Phelps, M.E.3    Kuhl, D.E.4
  • 16
    • 0028700063 scopus 로고
    • Accelerated image reconstruction using ordered subsets of projection data
    • Hudson H.M., Larkin R.S. Accelerated image reconstruction using ordered subsets of projection data. IEEE Trans. Med. Imag. 13:1994;601-609.
    • (1994) IEEE Trans. Med. Imag. , vol.13 , pp. 601-609
    • Hudson, H.M.1    Larkin, R.S.2
  • 18
    • 0030969958 scopus 로고    scopus 로고
    • Simultaneous emission and transmission (SET) scanning in neurological PET studies
    • Meikle S.R., Eberl S., Hooper P.K., Fulham M.J. Simultaneous emission and transmission (SET) scanning in neurological PET studies. J. Comput. Assist. Tomogr. 21:1997;487-497.
    • (1997) J. Comput. Assist. Tomogr. , vol.21 , pp. 487-497
    • Meikle, S.R.1    Eberl, S.2    Hooper, P.K.3    Fulham, M.J.4
  • 19
    • 85031079026 scopus 로고    scopus 로고
    • Experimental evaluation of filtered back projection versus iterative reconstruction using statistical parametric mapping analysis of PET activation studies
    • Mesina C.T., Boellaard R., Jongbloed G., Vaart van der A.W., Lammertsma A.A. Experimental evaluation of filtered back projection versus iterative reconstruction using statistical parametric mapping analysis of PET activation studies. J. Nucl. Med. 43:(Suppl):2002;218P.
    • (2002) J. Nucl. Med. , vol.43 , Issue.SUPPL.
    • Mesina, C.T.1    Boellaard, R.2    Jongbloed, G.3    Vaart van der, A.W.4    Lammertsma, A.A.5
  • 20
    • 0024341837 scopus 로고
    • Online brain attenuation correction in PET: Towards a fully automated data handling in a clinical environment
    • Michel C., Bol A., De Volder A.G., Goffinet A.M. Online brain attenuation correction in PET towards a fully automated data handling in a clinical environment . Eur. J. Nucl. Med. 15:1989;712-718.
    • (1989) Eur. J. Nucl. Med. , vol.15 , pp. 712-718
    • Michel, C.1    Bol, A.2    De Volder, A.G.3    Goffinet, A.M.4
  • 21
    • 0020194763 scopus 로고
    • Maximum likelihood reconstruction for emission tomography
    • Shepp L.A., Vardi Y. Maximum likelihood reconstruction for emission tomography. IEEE Trans. Med. Imag. 1:1982;113-122.
    • (1982) IEEE Trans. Med. Imag. , vol.1 , pp. 113-122
    • Shepp, L.A.1    Vardi, Y.2
  • 22
  • 23
    • 0031916120 scopus 로고    scopus 로고
    • Effect of registration errors between transmission and emission scans on a SPECT system using sequential scanning
    • Stone C.D., McCormick J.W., Gilland D.R., Greer K.L., Coleman R.E., Jaszczak R.J. Effect of registration errors between transmission and emission scans on a SPECT system using sequential scanning. J. Nucl. Med. 39:1998;365-373.
    • (1998) J. Nucl. Med. , vol.39 , pp. 365-373
    • Stone, C.D.1    McCormick, J.W.2    Gilland, D.R.3    Greer, K.L.4    Coleman, R.E.5    Jaszczak, R.J.6
  • 24
    • 0025964996 scopus 로고
    • Validation of simultaneous PET emission and transmission scans
    • Thompson C.J., Ranger N., Evans A.C., Gjedde A. Validation of simultaneous PET emission and transmission scans. J. Nucl. Med. 32:1991;154-160.
    • (1991) J. Nucl. Med. , vol.32 , pp. 154-160
    • Thompson, C.J.1    Ranger, N.2    Evans, A.C.3    Gjedde, A.4
  • 25
    • 0035092988 scopus 로고    scopus 로고
    • Automated PET attenuation correction model for functional brain imaging
    • Weinzapfel B.T., Hutchins G.D. Automated PET attenuation correction model for functional brain imaging. J. Nucl. Med. 42:2001;483-491.
    • (2001) J. Nucl. Med. , vol.42 , pp. 483-491
    • Weinzapfel, B.T.1    Hutchins, G.D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.