메뉴 건너뛰기




Volumn 27, Issue 5, 2003, Pages 668-673

Rapid computed tomography technique to measure ventricular volumes in the child with suspected ventriculoperitoneal shunt failure II: Clinical application

Author keywords

Ventricular volume; Ventriculoperitoneal shunt

Indexed keywords

CLINICAL APPLICATION; CLINICAL COURSE; COMPUTED TOMOGRAPHY SCAN; HIGH PRESSURE; OBJECTIVE ASSESSMENT; VENTRICULAR VOLUME; VENTRICULOPERITONEAL; VENTRICULOPERITONEAL SHUNT; VOLUME ANALYSIS; VOLUME CHANGE;

EID: 0042887329     PISSN: 03638715     EISSN: None     Source Type: Journal    
DOI: 10.1097/00004728-200309000-00002     Document Type: Article
Times cited : (10)

References (18)
  • 1
    • 0036626629 scopus 로고    scopus 로고
    • The diagonal ventricular dimension: A method for predicting shunt malfunction on the basis of changes in ventricular size
    • Mesiwala AH, Avellino AM, Ellenbogen RG. The diagonal ventricular dimension: a method for predicting shunt malfunction on the basis of changes in ventricular size. Neurosurgery. 2002;50:1246-1251.
    • (2002) Neurosurgery , vol.50 , pp. 1246-1251
    • Mesiwala, A.H.1    Avellino, A.M.2    Ellenbogen, R.G.3
  • 3
    • 0018358364 scopus 로고
    • Cerebrospinal fluid shunt function and hydrocephalus in the pediatric age group: A radiographic/clinical correlation
    • Murtagh FR, Quencer RM, Poole CA. Cerebrospinal fluid shunt function and hydrocephalus in the pediatric age group: a radiographic/clinical correlation. Radiology. 1979;132:385-388.
    • (1979) Radiology , vol.132 , pp. 385-388
    • Murtagh, F.R.1    Quencer, R.M.2    Poole, C.A.3
  • 4
    • 0018599195 scopus 로고
    • Increased intraventricular pressure without ventriculomegaly in children with shunts: "Normal volume" hydrocephalus
    • Engel M, Carmel PW, Chutorian AM. Increased intraventricular pressure without ventriculomegaly in children with shunts: "normal volume" hydrocephalus. Neurosurgery. 1979;5:549-552.
    • (1979) Neurosurgery , vol.5 , pp. 549-552
    • Engel, M.1    Carmel, P.W.2    Chutorian, A.M.3
  • 5
    • 84856753479 scopus 로고
    • An encephalographic ratio for estimating ventricular enlargement and cerebral atrophy
    • Evans WA. An encephalographic ratio for estimating ventricular enlargement and cerebral atrophy. Arch Neurol Psychiatry. 1942;47:931-937.
    • (1942) Arch Neurol Psychiatry , vol.47 , pp. 931-937
    • Evans, W.A.1
  • 6
    • 0032440893 scopus 로고    scopus 로고
    • Frontal and occipital horn ratio: A linear estimate of ventricular size for multiple imaging modalities in pediatric hydrocephalus
    • O'Hayon BB, Drake JM, Ossip MG, et al. Frontal and occipital horn ratio: a linear estimate of ventricular size for multiple imaging modalities in pediatric hydrocephalus. Pediatr Neurosurg. 1998;29:245-249.
    • (1998) Pediatr Neurosurg , vol.29 , pp. 245-249
    • O'Hayon, B.B.1    Drake, J.M.2    Ossip, M.G.3
  • 7
    • 0025821831 scopus 로고
    • Is the VBR still a useful measure of changes in the cerebral ventricles?
    • Woods BT, Douglass A, Gescuk B. Is the VBR still a useful measure of changes in the cerebral ventricles? Psychiatry Res. 1991;40:1-10.
    • (1991) Psychiatry Res , vol.40 , pp. 1-10
    • Woods, B.T.1    Douglass, A.2    Gescuk, B.3
  • 8
    • 0025371351 scopus 로고
    • Computerized volume measurement of brain structure
    • Ashtari M, Zito JL, Gold BI, et al. Computerized volume measurement of brain structure. Invest Radiol. 1990;25:798-805.
    • (1990) Invest Radiol , vol.25 , pp. 798-805
    • Ashtari, M.1    Zito, J.L.2    Gold, B.I.3
  • 9
    • 0022613203 scopus 로고
    • A fully-automated computer-assisted method of CT brain scan analysis for the measurement of cerebrospinal fluid spaces and brain absorption density
    • Baldy RE, Brindley GS, Ewusi-Mensah I, et al. A fully-automated computer-assisted method of CT brain scan analysis for the measurement of cerebrospinal fluid spaces and brain absorption density. Neuroradiology. 1986;28:109-117.
    • (1986) Neuroradiology , vol.28 , pp. 109-117
    • Baldy, R.E.1    Brindley, G.S.2    Ewusi-Mensah, I.3
  • 10
    • 0029941648 scopus 로고    scopus 로고
    • Intracranial compartment volumes in patients with enlarged ventricles assessed by magnetic resonance-based image processing
    • Matsumae M, Kikinis R, Morocz I, et al. Intracranial compartment volumes in patients with enlarged ventricles assessed by magnetic resonance-based image processing. J Neurosurg. 1996;84:972-981.
    • (1996) J Neurosurg , vol.84 , pp. 972-981
    • Matsumae, M.1    Kikinis, R.2    Morocz, I.3
  • 11
    • 0036085815 scopus 로고    scopus 로고
    • Dementing disorders: Volumetric measurement of cerebrospinal fluid to distinguish normal from pathologic findings-feasibility study
    • Thacker NA, Varma AR, Bathgate D, et al. Dementing disorders: volumetric measurement of cerebrospinal fluid to distinguish normal from pathologic findings-feasibility study. Radiology. 2002;224:278-285.
    • (2002) Radiology , vol.224 , pp. 278-285
    • Thacker, N.A.1    Varma, A.R.2    Bathgate, D.3
  • 12
    • 0036294708 scopus 로고    scopus 로고
    • Volumetric measurements in the detection of reduced ventricular volume in patients with normal-pressure hydrocephalus whose clinical condition improved after ventriculoperitoneal shunt placement
    • Anderson RC, Grant JJ, de la Paz R, et al. Volumetric measurements in the detection of reduced ventricular volume in patients with normal-pressure hydrocephalus whose clinical condition improved after ventriculoperitoneal shunt placement. J Neurosurg. 2002;97:73-79.
    • (2002) J Neurosurg , vol.97 , pp. 73-79
    • Anderson, R.C.1    Grant, J.J.2    De la Paz, R.3
  • 13
    • 0022529543 scopus 로고
    • A quantitative index of ventricular and extraventricular intracranial CSF volumes using MR imaging
    • Condon BR, Patterson J, Wyper D, et al. A quantitative index of ventricular and extraventricular intracranial CSF volumes using MR imaging. J Comput Assist Tomogr. 1986;10:784-792.
    • (1986) J Comput Assist Tomogr , vol.10 , pp. 784-792
    • Condon, B.R.1    Patterson, J.2    Wyper, D.3
  • 14
    • 0027524667 scopus 로고
    • MR quantification of cerebral ventricular volume using a semiautomated algorithm
    • Johnson LA, Pearlman JD, Miller CA, et al. MR quantification of cerebral ventricular volume using a semiautomated algorithm. AJNR Am J Neuroradiol. 1993;14:1373-1378.
    • (1993) AJNR Am J Neuroradiol , vol.14 , pp. 1373-1378
    • Johnson, L.A.1    Pearlman, J.D.2    Miller, C.A.3
  • 15
    • 0028072733 scopus 로고
    • Accuracy of volume measurements of computed tomography and magnetic resonance imaging phantoms by three-dimensional reconstruction and preliminary clinical application
    • Disler DG, Marr DS, Rosenthal DI. Accuracy of volume measurements of computed tomography and magnetic resonance imaging phantoms by three-dimensional reconstruction and preliminary clinical application. Invest Radiol. 1994;29:739-745.
    • (1994) Invest Radiol , vol.29 , pp. 739-745
    • Disler, D.G.1    Marr, D.S.2    Rosenthal, D.I.3
  • 16
    • 0025361578 scopus 로고
    • Volume determinations of the encephalic ventricles with CT and MRI
    • Cramer GD, Allen DI, DiDio LJ. Volume determinations of the encephalic ventricles with CT and MRI. Surg Radiol Anat. 1990;12:59-64.
    • (1990) Surg Radiol Anat , vol.12 , pp. 59-64
    • Cramer, G.D.1    Allen, D.I.2    DiDio, L.J.3
  • 17
    • 0000656827 scopus 로고
    • Casts of the cerebral ventricles
    • Last R, Tompsett D. Casts of the cerebral ventricles. Br J Surg. 1953;40:525-543.
    • (1953) Br J Surg , vol.40 , pp. 525-543
    • Last, R.1    Tompsett, D.2
  • 18
    • 0021838036 scopus 로고
    • Brain atrophy in chronic alcoholic patients: A quantitative pathological study
    • Harper C, Kril J. Brain atrophy in chronic alcoholic patients: a quantitative pathological study. J Neurol Neurosurg Psychiatry. 1985;48:211-217.
    • (1985) J Neurol Neurosurg Psychiatry , vol.48 , pp. 211-217
    • Harper, C.1    Kril, J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.