메뉴 건너뛰기




Volumn 5030 I, Issue , 2003, Pages 319-326

Effect on DQE of screen energy weighting in mammography

Author keywords

Detective quantum efficiency; Mammography; Screen; X ray spectrum

Indexed keywords

COMPUTER SIMULATION; MONTE CARLO METHODS; PHOSPHORS; PHOTONS; QUANTUM EFFICIENCY; RADIATION DETECTORS; SPECTRUM ANALYSIS; X RAY RADIOGRAPHY; X RAY SCREENS;

EID: 0042878216     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.480198     Document Type: Conference Paper
Times cited : (7)

References (16)
  • 1
    • 0021625852 scopus 로고
    • A generalized detective quantum efficiency (DQE) approach to the analysis of x-ray imaging
    • Markku J. Tapiovaara and Robert F. Wagner, "A generalized detective quantum efficiency (DQE) approach to the analysis of x-ray imaging," Proc. SPIE, 454, 52-56, 1984.
    • (1984) Proc. SPIE , vol.454 , pp. 52-56
    • Tapiovaara, M.J.1    Wagner, R.F.2
  • 2
    • 0021812629 scopus 로고
    • SNR and DQE analysis of broad spectrum x-ray imaging
    • Corrigendum: Phys. Med. Biol, 31, 195, 1986
    • Markku J. Tapiovaara and Robert F. Wagner, "SNR and DQE analysis of broad spectrum x-ray imaging," Phys. Med. Biol., 30, 519-529, 1985. (Corrigendum: Phys. Med. Biol, 31, 195, 1986)
    • (1985) Phys. Med. Biol. , vol.30 , pp. 519-529
    • Tapiovaara, M.J.1    Wagner, R.F.2
  • 5
    • 0036035340 scopus 로고    scopus 로고
    • Depth-dependent phosphor blur in indirect x-ray imaging sensors
    • A. Badano and R. Leimbach, "Depth-dependent phosphor blur in indirect x-ray imaging sensors," Proc. SPIE, 4682, 94-106, 2002.
    • (2002) Proc. SPIE , vol.4682 , pp. 94-106
    • Badano, A.1    Leimbach, R.2
  • 6
    • 0035882002 scopus 로고    scopus 로고
    • Monte Carlo analysis of the spectral photon emission and extraction efficiency of organic light-emitting devices
    • A. Badano and J. Kanicki, "Monte Carlo analysis of the spectral photon emission and extraction efficiency of organic light-emitting devices," J. Appl. Phys., 90, 1827-1830, 2001.
    • (2001) J. Appl. Phys. , vol.90 , pp. 1827-1830
    • Badano, A.1    Kanicki, J.2
  • 7
    • 0000727366 scopus 로고
    • Light collection in scintillation detector composites for neutron detection
    • G. F. Knoll and T. F. Knoll, "Light collection in scintillation detector composites for neutron detection," IEEE Transactions on Nuclear Science, 35, 872-875, 1988.
    • (1988) IEEE Transactions on Nuclear Science , vol.35 , pp. 872-875
    • Knoll, G.F.1    Knoll, T.F.2
  • 8
    • 0025156138 scopus 로고
    • Model of the spatial-frequency-dependent detective quantum efficiency of phosphor screens
    • R. Nishikawa and M. J. Yaffe, "Model of the spatial-frequency-dependent detective quantum efficiency of phosphor screens," Med. Phys., 17, 894-904, 1990.
    • (1990) Med. Phys. , vol.17 , pp. 894-904
    • Nishikawa, R.1    Yaffe, M.J.2
  • 10
    • 0019497908 scopus 로고
    • Information transfer properties of x-ray fluorescent screens
    • C.E. Dick and J.W. Motz, "Information transfer properties of x-ray fluorescent screens," Med. Phys., 8, 337-346, 1981.
    • (1981) Med. Phys. , vol.8 , pp. 337-346
    • Dick, C.E.1    Motz, J.W.2
  • 11
    • 0025675170 scopus 로고
    • Conversion noise measurement for front and back x-ray intensifying screens
    • David P. Trauernicht and Richard Van Metter, "Conversion noise measurement for front and back x-ray intensifying screens," Proc. SPIE, 1231, 262-270, 1990.
    • (1990) Proc. SPIE , vol.1231 , pp. 262-270
    • Trauernicht, D.P.1    Van Metter, R.2
  • 13
    • 0015667930 scopus 로고
    • Absorption and noise in x-ray phosphors
    • R.K. Swank, "Absorption and noise in x-ray phosphors," J. Appl. Phys., 44, 4199-4203, 1973.
    • (1973) J. Appl. Phys. , vol.44 , pp. 4199-4203
    • Swank, R.K.1
  • 15
    • 0033849943 scopus 로고    scopus 로고
    • Mammographic imaging with a small format CCD-based digital cassette: Physical characteristics of a clinical system
    • S. Vendantham, A. Karellas, S. Suryanarayanan, M. Sayag, R. Kleehamer, R. Heidsieck, and C.J. D'Orsi, "Mammographic imaging with a small format CCD-based digital cassette: Physical characteristics of a clinical system, " Med. Phys, 27, 1832-1840, 2000.
    • (2000) Med. Phys. , vol.27 , pp. 1832-1840
    • Vendantham, S.1    Karellas, A.2    Suryanarayanan, S.3    Sayag, M.4    Kleehamer, R.5    Heidsieck, R.6    D'Orsi, C.J.7
  • 16
    • 0036145048 scopus 로고    scopus 로고
    • A comparison of the imaging properties of CCD-based devices used for small field digital mammography
    • D.S. Evans, A. Workman, and M. Payne, "A comparison of the imaging properties of CCD-based devices used for small field digital mammography," Phys. Med. Biol., 47, 117-135, 2002.
    • (2002) Phys. Med. Biol. , vol.47 , pp. 117-135
    • Evans, D.S.1    Workman, A.2    Payne, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.