메뉴 건너뛰기




Volumn 5030 I, Issue , 2003, Pages 490-503

Performance of prototype modules of a novel multislice CT detector based on CMOS photosensors

Author keywords

CMOS photodiode; Computed tomography (CT); Multislice detector

Indexed keywords

CMOS INTEGRATED CIRCUITS; COMPUTERIZED TOMOGRAPHY; CROSSTALK; PHOSPHORS; PHOTODIODES; SWITCHING; TUNGSTEN COMPOUNDS;

EID: 0042877327     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.480011     Document Type: Conference Paper
Times cited : (10)

References (6)
  • 1
    • 0042461933 scopus 로고    scopus 로고
    • Plasma Cell Design (PCD) code: A Monte Carlo package for modeling light distributions
    • J. Schug and J. Eilts, "Plasma Cell Design (PCD) Code: a Monte Carlo package for modeling light distributions", Philips internal report.
    • Philips Internal Report
    • Schug, J.1    Eilts, J.2
  • 2
    • 0041961323 scopus 로고    scopus 로고
    • Geant4, http://wwwinfo.cern.ch/asd/geant4/geant4.html Geant4: a Simulation toolkit, GEANT4 (S. Agostinelli et al.), CERN-IT-2002-003, KEK Preprint 2002-85, SLAC-PUB-9350, Aug. 2002, 86pp, Nucl. Instr. and Meth. A (2002), submitted.
    • Geant4
  • 3
    • 0042630427 scopus 로고    scopus 로고
    • Geant4: A Simulation toolkit
    • CERN-IT-2002-003, KEK Preprint 2002-85, SLAC-PUB-9350, Aug.
    • Geant4, http://wwwinfo.cern.ch/asd/geant4/geant4.html Geant4: a Simulation toolkit, GEANT4 (S. Agostinelli et al.), CERN-IT-2002-003, KEK Preprint 2002-85, SLAC-PUB-9350, Aug. 2002, 86pp, Nucl. Instr. and Meth. A (2002), submitted.
    • (2002) GEANT4 , pp. 86
    • Agostinelli, S.1
  • 4
    • 85031174705 scopus 로고    scopus 로고
    • submitted
    • Geant4, http://wwwinfo.cern.ch/asd/geant4/geant4.html Geant4: a Simulation toolkit, GEANT4 (S. Agostinelli et al.), CERN-IT-2002-003, KEK Preprint 2002-85, SLAC-PUB-9350, Aug. 2002, 86pp, Nucl. Instr. and Meth. A (2002), submitted.
    • (2002) Nucl. Instr. and Meth. A
  • 5
    • 0018399326 scopus 로고
    • Computation of bremsstrahlung x-ray spectra and comparison with spectra measured with a Ge(Li) detector
    • R. Birch and M. Marshall, "Computation of bremsstrahlung x-ray spectra and comparison with spectra measured with a Ge(Li) detector", Phys. Med. Biol. 24, 505-517 (1979).
    • (1979) Phys. Med. Biol. , vol.24 , pp. 505-517
    • Birch, R.1    Marshall, M.2
  • 6
    • 0041460126 scopus 로고    scopus 로고
    • private communication
    • H. Wieczorek, private communication.
    • Wieczorek, H.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.