메뉴 건너뛰기




Volumn 25, Issue 16, 2003, Pages 1357-1361

A microbial fuel cell with improved cathode reaction as a low biochemical oxygen demand sensor

Author keywords

Biochemical oxygen demand; Cathode reaction; Microbial fuel cell; Oligotroph

Indexed keywords

OXYGEN;

EID: 0042856665     PISSN: 01415492     EISSN: None     Source Type: Journal    
DOI: 10.1023/A:1024984521699     Document Type: Article
Times cited : (111)

References (11)
  • 2
    • 0034302213 scopus 로고    scopus 로고
    • Optical fiber biosensor for the determination of low biochemical oxygen demand
    • Chee G J, Nomura Y, Ikebukuro K, Karube I (2000) Optical fiber biosensor for the determination of low biochemical oxygen demand. Biosens. Bioelectron. 15: 371-376.
    • (2000) Biosens. Bioelectron. , vol.15 , pp. 371-376
    • Chee, G.J.1    Nomura, Y.2    Ikebukuro, K.3    Karube, I.4
  • 3
    • 0032905929 scopus 로고    scopus 로고
    • Biosensor for the estimation of low biochemical oxygen demand
    • Chee GJ, Nomura Y, Karube I (1999) Biosensor for the estimation of low biochemical oxygen demand. Anal. Chem. Acta 379: 185-191.
    • (1999) Anal. Chem. Acta , vol.379 , pp. 185-191
    • Chee, G.J.1    Nomura, Y.2    Karube, I.3
  • 7
    • 0037386906 scopus 로고    scopus 로고
    • Novel BOD (biological oxygen demand) sensor using mediator-less microbial fuel cell
    • Kim BH, Chang IS, Gil GC, Park HS, Kim HJ (2003) Novel BOD (biological oxygen demand) sensor using mediator-less microbial fuel cell. Biotechnol. Lett. 25: 541-545.
    • (2003) Biotechnol. Lett. , vol.25 , pp. 541-545
    • Kim, B.H.1    Chang, I.S.2    Gil, G.C.3    Park, H.S.4    Kim, H.J.5
  • 9
    • 0037757520 scopus 로고    scopus 로고
    • Use of acetate for enrichment of electrochemically active microorganisms and their 16S rDNA analyses
    • in press
    • Lee J, Phung NT, Chang IS, Kim BH, Sung HC (2003) Use of acetate for enrichment of electrochemically active microorganisms and their 16S rDNA analyses. FEMS Microbiol. Lett., in press.
    • (2003) FEMS Microbiol. Lett.
    • Lee, J.1    Phung, N.T.2    Chang, I.S.3    Kim, B.H.4    Sung, H.C.5
  • 10
    • 0030972916 scopus 로고    scopus 로고
    • Measurement of BOD: Correlation between 5-day BOD and commercial BOD biosensor values
    • Marty JL, Olive D, Asano Y (1997) Measurement of BOD: correlation between 5-day BOD and commercial BOD biosensor values. Environ. Technol. 18: 333-337.
    • (1997) Environ. Technol. , vol.18 , pp. 333-337
    • Marty, J.L.1    Olive, D.2    Asano, Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.