메뉴 건너뛰기




Volumn 69, Issue 4, 1998, Pages 1909-1913

A programmable prescaler for minimizing counting errors with PC-based data acquisition cards

Author keywords

[No Author keywords available]

Indexed keywords


EID: 0042829709     PISSN: 00346748     EISSN: None     Source Type: Journal    
DOI: 10.1063/1.1148863     Document Type: Article
Times cited : (1)

References (15)
  • 2
    • 84975577915 scopus 로고
    • W. Demtröder, Laser Spectroscopy Basic Concepts and Instrumentation (Springer, Berlin, 1982); R. G. Tull, Appl. Opt. 7, 2023 (1968).
    • (1968) Appl. Opt. , vol.7 , pp. 2023
    • Tull, R.G.1
  • 4
    • 85034309530 scopus 로고    scopus 로고
    • note
    • Many of these boards, including the Computer Boards Inc. CIO-CTR05, which we own, and the Keithley-Metrabyte CTM-05/A, are based on the AMD-9513 counter/timer chip, which imposes the 7 MHz frequency limit.
  • 8
    • 11744371245 scopus 로고
    • J. Sabol, Rev. Sci. Instrum. 59, 2089 (1988); Instrum. Exp. Tech. 32, 1315 (1989).
    • (1988) Rev. Sci. Instrum. , vol.59 , pp. 2089
    • Sabol, J.1
  • 9
    • 11744319212 scopus 로고
    • J. Sabol, Rev. Sci. Instrum. 59, 2089 (1988); Instrum. Exp. Tech. 32, 1315 (1989).
    • (1989) Instrum. Exp. Tech. , vol.32 , pp. 1315
  • 11
  • 12
    • 0021982887 scopus 로고
    • B. H. Candy, Rev. Sci. Instrum. 56, 183 (1985); Rev. Sci. Instrum. 56, 194 (1985).
    • (1985) Rev. Sci. Instrum. , vol.56 , pp. 194
  • 13
    • 85034285224 scopus 로고    scopus 로고
    • note
    • Our circuit generates one output pulse for every n input pulses, where n is defined as the prescale factor. Thus, when the prescale factor is "1", input pulses are sent directly to the output pulse shaping circuit.
  • 15
    • 85034299403 scopus 로고    scopus 로고
    • note
    • Figure 2 illustrates that for all average event frequencies considered, a divide-by-eight prescaler will record over 99% of the events. We have verified this assumption experimentally by making an independent measurement that compares the event frequency recorded by our prescaler/ counter with that recorded by a 500 MHz counter (HP 5345A).


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.