메뉴 건너뛰기




Volumn 6, Issue 3, 2003, Pages 166-175

Static analysis of nippers pinch

Author keywords

Biomechanics; Finger; Grip force; Precision grip

Indexed keywords

ARTICLE; BIOMECHANICS; DEVICE; FINGER JOINT; GRIP STRENGTH; HAND FUNCTION; HAND GRIP; MUSCLE ISOMETRIC CONTRACTION; TORQUE;

EID: 0042804961     PISSN: 10947159     EISSN: None     Source Type: Journal    
DOI: 10.1046/j.1525-1403.2003.03026.x     Document Type: Article
Times cited : (11)

References (21)
  • 2
    • 0043036912 scopus 로고    scopus 로고
    • Influence of flexor pollicis longus muscle's joint moments on the direction and magnitude of its thumbtip force
    • Cleveland, OH
    • Towles J, Murray W, Valero-Cuevas F, Zajac F. Influence of flexor pollicis longus muscle's joint moments on the direction and magnitude of its thumbtip force. Proceedings of the VI IFESS: Cleveland, OH. 2001:291-293.
    • (2001) Proceedings of the VI IFESS , pp. 291-293
    • Towles, J.1    Murray, W.2    Valero-Cuevas, F.3    Zajac, F.4
  • 4
    • 0033692329 scopus 로고    scopus 로고
    • Applying principles of robotics to understand the biomechanics, neuoromuscular control and clinical rehabilitation of human digits
    • San Francisco, CA
    • Valero-Cuevas FJ. Applying principles of robotics to understand the biomechanics, neuoromuscular control and clinical rehabilitation of human digits. Proceedings of the 2000 IEEE ICRA. San Francisco, CA. 2000:270-275.
    • (2000) Proceedings of the 2000 IEEE ICRA , pp. 270-275
    • Valero-Cuevas, F.J.1
  • 6
    • 0031031220 scopus 로고    scopus 로고
    • Instrumented objects for quantitative evaluation of hand grasp
    • Memberg WD, Crago PE. Instrumented objects for quantitative evaluation of hand grasp. J Rehab Res Dev 1997;34:82-90.
    • (1997) J Rehab Res Dev , vol.34 , pp. 82-90
    • Memberg, W.D.1    Crago, P.E.2
  • 7
    • 0033033497 scopus 로고    scopus 로고
    • A force transducer to measure individual finger loads during activities of daily living
    • Fowler NK, Nicol AC. A force transducer to measure individual finger loads during activities of daily living. J Biomech 1999;32:721-725.
    • (1999) J Biomech , vol.32 , pp. 721-725
    • Fowler, N.K.1    Nicol, A.C.2
  • 8
    • 0035218107 scopus 로고    scopus 로고
    • A novel force transducer for the measurement of grip force
    • Chadwick EKJ, Nicol AC. A novel force transducer for the measurement of grip force. J Biomech 2001;34:125-128.
    • (2001) J Biomech , vol.34 , pp. 125-128
    • Chadwick, E.K.J.1    Nicol, A.C.2
  • 9
    • 0034944580 scopus 로고    scopus 로고
    • Activation patterns of the thumb muscles during stable and unstable pinch tasks
    • Johanson ME, Valero-Cuevas FJ, Hentz VR. Activation patterns of the thumb muscles during stable and unstable pinch tasks. J Hand Surg 2001;26A:698-705.
    • (2001) J Hand Surg , vol.26 A , pp. 698-705
    • Johanson, M.E.1    Valero-Cuevas, F.J.2    Hentz, V.R.3
  • 10
    • 0019989209 scopus 로고
    • Factors contributing to the regulation and clinical assessment of muscular strength
    • Smidt GL, Rogers MR. Factors contributing to the regulation and clinical assessment of muscular strength. Phys Ther 1982;62:1283-1290.
    • (1982) Phys Ther , vol.62 , pp. 1283-1290
    • Smidt, G.L.1    Rogers, M.R.2
  • 11
    • 0032824861 scopus 로고    scopus 로고
    • Handgrip strength testing. A review of the literature
    • Innes E. Handgrip strength testing. A review of the literature. Aust Occup Ther J 1999;46:120-140.
    • (1999) Aust Occup Ther J , vol.46 , pp. 120-140
    • Innes, E.1
  • 12
    • 0033810763 scopus 로고    scopus 로고
    • Quantification of fingertip force reduction in the forefinger following simulated paralysis of extensor and intrinsic muscles
    • Valero-Cuevas FJ, Towles JD, Hentz VR. Quantification of fingertip force reduction in the forefinger following simulated paralysis of extensor and intrinsic muscles. J Biomech 2000;33:1601-1609.
    • (2000) J Biomech , vol.33 , pp. 1601-1609
    • Valero-Cuevas, F.J.1    Towles, J.D.2    Hentz, V.R.3
  • 14
    • 0031166352 scopus 로고    scopus 로고
    • Human prehension and dexterous robot hands
    • Iberall T. Human prehension and dexterous robot hands. Int J Robot Res 1997;16:285-299.
    • (1997) Int J Robot Res , vol.16 , pp. 285-299
    • Iberall, T.1
  • 16
    • 0024683535 scopus 로고
    • On grasp choice, grasp models and the design of hands for manufacturing tasks
    • Cutkosky MR. On grasp choice, grasp models and the design of hands for manufacturing tasks. IEEE Trans Robot Automat 1989;5:269-279.
    • (1989) IEEE Trans Robot Automat , vol.5 , pp. 269-279
    • Cutkosky, M.R.1
  • 17
    • 0032881368 scopus 로고    scopus 로고
    • A demonstration of the validity of a 3-D video motion analysis method for measuring finger flexion and extension
    • Rash GS, Belliappa PP, Wachowiak MP, Somia NN, Gupta A. A demonstration of the validity of a 3-D video motion analysis method for measuring finger flexion and extension. J Biomech 1999;32:1337-1341.
    • (1999) J Biomech , vol.32 , pp. 1337-1341
    • Rash, G.S.1    Belliappa, P.P.2    Wachowiak, M.P.3    Somia, N.N.4    Gupta, A.5
  • 18
    • 0028413346 scopus 로고
    • Coordination of index finger movements
    • Darling WD, Cole KJ, Miller GF. Coordination of index finger movements. J Biomech 1994;27:479-491.
    • (1994) J Biomech , vol.27 , pp. 479-491
    • Darling, W.D.1    Cole, K.J.2    Miller, G.F.3
  • 19
    • 0017366070 scopus 로고
    • A biomechanical analysis of the metacarpo-phalangeal joint
    • Berme N, Paul JP, Purves WK. A biomechanical analysis of the metacarpo-phalangeal joint. J Biomech 1977;10:409-412.
    • (1977) J Biomech , vol.10 , pp. 409-412
    • Berme, N.1    Paul, J.P.2    Purves, W.K.3
  • 21
    • 0013183387 scopus 로고    scopus 로고
    • Measurement of sensory-motor control performance capacities. Tracking tasks
    • Bronzino JD. Boca Raton: CRC Press
    • Jones RD. Measurement of sensory-motor control performance capacities. Tracking tasks. In: Bronzino JD. The Biomedical Engineering Handbook, 2nd edn, Vol. II. Boca Raton: CRC Press, 2000.
    • (2000) The Biomedical Engineering Handbook, 2nd Edn. , vol.2
    • Jones, R.D.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.