메뉴 건너뛰기




Volumn 18, Issue 11, 2003, Pages 1385-1390

An ultrasensitive and stable potentiometric immunosensor

Author keywords

Biosensor; Immunoassay; Polypyrrole; Potentiometric; Reproducible; Stable; Ultrasensitive

Indexed keywords

ASSAYS; BLOOD; COMPLEXATION; POLYPYRROLES; SENSITIVITY ANALYSIS; SURFACE PROPERTIES;

EID: 0042744882     PISSN: 09565663     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0956-5663(03)00066-6     Document Type: Article
Times cited : (83)

References (14)
  • 1
    • 0027426349 scopus 로고
    • Questions of quality: How much HBsAg is there in this sample and is our assay sensitive enough to detect it
    • Barbara J. Questions of quality: how much HBsAg is there in this sample and is our assay sensitive enough to detect it. Vox Sang. 65:1993;249-250.
    • (1993) Vox Sang. , vol.65 , pp. 249-250
    • Barbara, J.1
  • 2
    • 0002708985 scopus 로고
    • Mechanism of ionic and redox sensitivity of p-type conducting polymers. Part 2. Experimental study of polypyrrole
    • Bobacka J., Gao Z., Ivaska A., Lewenstam A. Mechanism of ionic and redox sensitivity of p-type conducting polymers. Part 2. Experimental study of polypyrrole. J. Electroanal. Chem. 368:1994;33-41.
    • (1994) J. Electroanal. Chem. , vol.368 , pp. 33-41
    • Bobacka, J.1    Gao, Z.2    Ivaska, A.3    Lewenstam, A.4
  • 3
    • 0033620585 scopus 로고    scopus 로고
    • Biomolecule immobilization on electrode surfaces by entrapment or attachment to electrochemically polymerized films. A review
    • Cosnier, S., 1999. Biomolecule immobilization on electrode surfaces by entrapment or attachment to electrochemically polymerized films. A review. Biosens. Bioelectron. 14, 443-456.
    • (1999) Biosens. Bioelectron. , vol.14 , pp. 443-456
    • Cosnier, S.1
  • 4
    • 0031910714 scopus 로고    scopus 로고
    • Immunosensors: Electrochemical sensing and other engineering approaches
    • Ghindilis A., Atanasov A., Wilkins M., Wilkins E. Immunosensors: electrochemical sensing and other engineering approaches. Biosens. Bioelectron. 13:(1):1998;113-131.
    • (1998) Biosens. Bioelectron. , vol.13 , Issue.1 , pp. 113-131
    • Ghindilis, A.1    Atanasov, A.2    Wilkins, M.3    Wilkins, E.4
  • 5
    • 0034206075 scopus 로고    scopus 로고
    • Cytosensor® microphysiometer: Technology and recent applications
    • Hafner F. Cytosensor® microphysiometer: technology and recent applications. Biosens. Bioelectron. 15:(3-4):2000;149-158.
    • (2000) Biosens. Bioelectron. , vol.15 , Issue.3-4 , pp. 149-158
    • Hafner, F.1
  • 6
    • 0038180593 scopus 로고
    • Potentiometric biosensors based on redox electrodes
    • Chapter 10. Turner, A.P.F., Karube, I., Wilson G.S. (Eds.), Oxford University Press, Oxford
    • Lemuel, B., Wingward, J.R., Castner, J., 1987. Potentiometric biosensors based on redox electrodes. Chapter 10. In: Turner, A.P.F., Karube, I., Wilson G.S. (Eds.), Biosensors: Fundamentals and Applications, Oxford University Press, Oxford.
    • (1987) Biosensors: Fundamentals and Applications
    • Lemuel, B.1    Wingward, J.R.2    Castner, J.3
  • 7
    • 0033972703 scopus 로고    scopus 로고
    • Rapid detection and identification of biological and chemical agents by immunoassay, gene probe assay and enzyme inhibition using a silicon-based biosensor
    • Lee W., Thompson H.G., Hall J.G., Bader D.E. Rapid detection and identification of biological and chemical agents by immunoassay, gene probe assay and enzyme inhibition using a silicon-based biosensor. Biosens. Bioelectron. 14:(10-11):2000;795-804.
    • (2000) Biosens. Bioelectron. , vol.14 , Issue.10-11 , pp. 795-804
    • Lee, W.1    Thompson, H.G.2    Hall, J.G.3    Bader, D.E.4
  • 8
    • 0041471000 scopus 로고
    • Mechanism of ionic and redox sensitivity of p-type conducting polymers. Part 1. Theory
    • Lewenstam A., Bobacka J., Ivaska A. Mechanism of ionic and redox sensitivity of p-type conducting polymers. Part 1. Theory. J. Electroanal. Chem. 368:1994;23-31.
    • (1994) J. Electroanal. Chem. , vol.368 , pp. 23-31
    • Lewenstam, A.1    Bobacka, J.2    Ivaska, A.3
  • 9
    • 0035975024 scopus 로고    scopus 로고
    • Electrochemical impedance spectroscopy as a platform for reagentles bioaffinitty sensing
    • Lillie G., Payne P., Vadgama P. Electrochemical impedance spectroscopy as a platform for reagentles bioaffinitty sensing. Sens. Actuators B. 78:2001;249-256.
    • (2001) Sens. Actuators B , vol.78 , pp. 249-256
    • Lillie, G.1    Payne, P.2    Vadgama, P.3
  • 10
    • 0031256456 scopus 로고    scopus 로고
    • Modelling potentiometric sensitivity of conductive polymer
    • Michalska A., Ivaska A., Lewenstam A. Modelling potentiometric sensitivity of conductive polymer. Anal. Chem. 69:1997;4060-4064.
    • (1997) Anal. Chem. , vol.69 , pp. 4060-4064
    • Michalska, A.1    Ivaska, A.2    Lewenstam, A.3
  • 12
    • 0033097692 scopus 로고    scopus 로고
    • Microfabrication of Ppy microactuators and other conjugated polymer devices
    • Smela E. Microfabrication of Ppy microactuators and other conjugated polymer devices. J. Micromech. Microeng. 9:1999;1-18.
    • (1999) J. Micromech. Microeng. , vol.9 , pp. 1-18
    • Smela, E.1
  • 13
    • 0034623681 scopus 로고    scopus 로고
    • Immunosensor for the determination of the herbicide simazine based on an ion-selective field-effect transistor
    • Starodub N.F., Dzantievb B.B., Staroduba V.M., Zherdevb A.V. Immunosensor for the determination of the herbicide simazine based on an ion-selective field-effect transistor. Anal. Chim. Acta. 424:(1):2000;37-43.
    • (2000) Anal. Chim. Acta , vol.424 , Issue.1 , pp. 37-43
    • Starodub, N.F.1    Dzantievb, B.B.2    Staroduba, V.M.3    Zherdevb, A.V.4
  • 14
    • 0001401601 scopus 로고
    • Practice and theory of enzyme immunoassays
    • R.H. Burdon, van Knippenberg P.H. Elsevier
    • Tijssen P. Practice and theory of enzyme immunoassays. Burdon R.H., van Knippenberg P.H. Laboratory Techniques in Biochemistry and Molecular Biology. 15:1985;135 Elsevier.
    • (1985) Laboratory Techniques in Biochemistry and Molecular Biology , vol.15 , pp. 135
    • Tijssen, P.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.