메뉴 건너뛰기




Volumn 20, Issue 3, 2003, Pages 532-537

Continuous separation of glucose and fructose at high concentration using two-section simulated moving bed process

Author keywords

Chromatography; Fructose; Glucose; Separation; Two Section SMB

Indexed keywords

CHROMATOGRAPHIC ANALYSIS; CONCENTRATION (PROCESS); GLUCOSE; MASS TRANSFER; MIXTURES;

EID: 0042744694     PISSN: 02561115     EISSN: None     Source Type: Journal    
DOI: 10.1007/BF02705561     Document Type: Article
Times cited : (30)

References (17)
  • 1
    • 0037497516 scopus 로고
    • The separation of volatile liquid mixtures by continuous gas-liquid chromatography
    • Barker, P. E. and Critcher, D., "The Separation of Volatile Liquid Mixtures by Continuous Gas-Liquid Chromatography," Chem. Eng. Sci., 13, 82 (1960).
    • (1960) Chem. Eng. Sci. , vol.13 , pp. 82
    • Barker, P.E.1    Critcher, D.2
  • 2
    • 0042241657 scopus 로고
    • Sequential chromatographic equipment for separation of a wide range of organic mixtures
    • Barker, P. E. and Deeble, R. E., "Sequential Chromatographic Equipment for Separation of a Wide Range of Organic Mixtures," Chromatographia, 8(2), 67 (1975).
    • (1975) Chromatographia , vol.8 , Issue.2 , pp. 67
    • Barker, P.E.1    Deeble, R.E.2
  • 3
    • 84963068207 scopus 로고
    • Preparative scale separation of multicomponent mixtures by continuous gas-liquid chromatography
    • Barker, P. E. and Huntington, D. H., "Preparative Scale Separation of Multicomponent Mixtures by Continuous Gas-Liquid Chromatography," J. Gas. Chromtogra., 4, 9 (1966).
    • (1966) J. Gas. Chromtogra. , vol.4 , pp. 9
    • Barker, P.E.1    Huntington, D.H.2
  • 4
    • 0001979650 scopus 로고
    • Molex: Case history of a process
    • Broughton, D. B., "Molex: Case History of a Process," Chem. Eng. Prog., 64(8), 60 (1968).
    • (1968) Chem. Eng. Prog. , vol.64 , Issue.8 , pp. 60
    • Broughton, D.B.1
  • 5
    • 0021880082 scopus 로고
    • An experimental study of a simulated counter-current adsorption system: I. Isothermal steady state operation
    • Ching, C. B. and Ruthven, D. M., "An Experimental Study of a Simulated Counter-Current Adsorption System: I. Isothermal Steady State Operation," Chem. Eng. Sci., 40(6), 877 (1985).
    • (1985) Chem. Eng. Sci. , vol.40 , Issue.6 , pp. 877
    • Ching, C.B.1    Ruthven, D.M.2
  • 7
    • 0041741250 scopus 로고
    • Semicontinuous countercurrent chromatographic refiner
    • Ganetsos, G. and Barker, P. E., Eds., Marcel Dekker Inc., New York
    • Ganetsos, G. and Barker, P. E., "Semicontinuous Countercurrent Chromatographic Refiner," In Preparative and Production Scale Chromatography; Ganetsos, G. and Barker, P. E., Eds., Marcel Dekker Inc., New York (1993).
    • (1993) Preparative and Production Scale Chromatography
    • Ganetsos, G.1    Barker, P.E.2
  • 9
    • 0022882971 scopus 로고
    • Simulated counter-current adsorption processes: A theoretical analysis of the effect of subdividing the adsorbent bed
    • Hidajat, K., Ching, C. B. and Ruthven, D. M., "Simulated Counter-current Adsorption Processes: A Theoretical Analysis of the Effect of Subdividing the Adsorbent Bed," Chem. Eng. Sci., 41(11), 2953 (1986).
    • (1986) Chem. Eng. Sci. , vol.41 , Issue.11 , pp. 2953
    • Hidajat, K.1    Ching, C.B.2    Ruthven, D.M.3
  • 10
    • 0035564635 scopus 로고    scopus 로고
    • The application of simulated moving bed chromatography for the separation between 2,6- and 2,7-dimethylnaphthalene
    • Kim, Y. D., Lee, J. K. and Cho, Y. S., "The Application of Simulated Moving Bed Chromatography for the Separation Between 2,6- and 2,7-Dimethylnaphthalene," Korean J. Chem. Eng., 18(6), 971 (2001).
    • (2001) Korean J. Chem. Eng. , vol.18 , Issue.6 , pp. 971
    • Kim, Y.D.1    Lee, J.K.2    Cho, Y.S.3
  • 11
    • 0026836676 scopus 로고
    • A theoretical model for the separation of glucose and fructose by using semi-continuous chromatographic refiner
    • Lee, K. N. and Lee, W. K., "A Theoretical Model for the Separation of Glucose and Fructose by Using Semi-Continuous Chromatographic Refiner," Sep. Sci. Tech., 27(3), 295 (1992).
    • (1992) Sep. Sci. Tech. , vol.27 , Issue.3 , pp. 295
    • Lee, K.N.1    Lee, W.K.2
  • 12
    • 0018466413 scopus 로고
    • Simulation of binary adsorption in continuous counter-current operation in comparison with other operating models
    • Liapis, A. I. and Rippen, D. W. T., "Simulation of Binary Adsorption in Continuous Counter-Current Operation in Comparison with Other Operating Models," AIChE J., 25, 455 (1979).
    • (1979) AIChE J. , vol.25 , pp. 455
    • Liapis, A.I.1    Rippen, D.W.T.2
  • 13
    • 0031205764 scopus 로고    scopus 로고
    • Dynamics of simulated moving-bed adsorption separation processws
    • Lu, Z. P. and Ching, C. B., "Dynamics of Simulated Moving-Bed Adsorption Separation Processws," Sep. Sci. Tech., 32(12), 1993 (1997).
    • (1997) Sep. Sci. Tech. , vol.32 , Issue.12 , pp. 1993
    • Lu, Z.P.1    Ching, C.B.2
  • 14
    • 0035847187 scopus 로고    scopus 로고
    • Preparative enantioseparation by simulated moving bed chromatography
    • Michael, S. and Jochen. S., "Preparative Enantioseparation by Simulated Moving Bed Chromatography," J. Chromatogra A, 906, 399 (2001).
    • (2001) J. Chromatogra A , vol.906 , pp. 399
    • Michael, S.1    Jochen, S.2
  • 15
    • 0024872062 scopus 로고
    • Counter-current and simulated counter-current adsorption separation processes
    • Ruthven, D. M. and Ching, C. B., "Counter-current and Simulated Counter-current Adsorption Separation Processes," Chem. Eng. Sci., 44(5), 1011 (1989).
    • (1989) Chem. Eng. Sci. , vol.44 , Issue.5 , pp. 1011
    • Ruthven, D.M.1    Ching, C.B.2
  • 17
    • 0041741248 scopus 로고    scopus 로고
    • Enantio-separation of R,S-ibuprofen using simulated moving bed chromatography
    • Won, J. H., Cho, Y. S., Kim, Y. D. and Ahn, D. J., "Enantio-Separation of R,S-Ibuprofen using Simulated Moving Bed Chromatography," HWAHAK KONGHAK, 39(6), 685 (2001).
    • (2001) Hwahak Konghak , vol.39 , Issue.6 , pp. 685
    • Won, J.H.1    Cho, Y.S.2    Kim, Y.D.3    Ahn, D.J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.