메뉴 건너뛰기




Volumn 12, Issue 3, 2003, Pages 240-248

The clinical effects of cold application on the production of electrically induced involuntary muscle contractions

Author keywords

Cryotherapy; Isometric; Torque

Indexed keywords

ADULT; ARTICLE; CLINICAL ARTICLE; CRYOTHERAPY; ELECTROSTIMULATION; FEMALE; HUMAN; INVOLUNTARY MOVEMENT; JOINT MOBILITY; MALE; MUSCLE EXCITATION; MUSCLE ISOMETRIC CONTRACTION; MUSCLE STRENGTH; MUSCLE TETANIC CONTRACTION; NEUROMUSCULAR FUNCTION; OUTPATIENT; PAIN THRESHOLD; PERIPHERAL NERVE; TORQUE;

EID: 0042732013     PISSN: 10566716     EISSN: None     Source Type: Journal    
DOI: 10.1123/jsr.12.3.240     Document Type: Article
Times cited : (2)

References (23)
  • 1
    • 0021235466 scopus 로고
    • Comparison of electrical stimulation with conventional isometric exercise
    • Currier DP, Mann R. Comparison of electrical stimulation with conventional isometric exercise. J Orthop Sports Phys Ther. 1984;5:318-323.
    • (1984) J Orthop Sports Phys Ther , vol.5 , pp. 318-323
    • Currier, D.P.1    Mann, R.2
  • 4
    • 0026761096 scopus 로고
    • Effect of variation in the burst and carrier frequency modes of neuromuscular electrical stimulation on pain perception of healthy subjects
    • Rooney JG, Currier DP, Nitz AJ, Delitto A. Effect of variation in the burst and carrier frequency modes of neuromuscular electrical stimulation on pain perception of healthy subjects. Phys Ther. 1992;72:800-809.
    • (1992) Phys Ther , vol.72 , pp. 800-809
    • Rooney, J.G.1    Currier, D.P.2    Nitz, A.J.3    Delitto, A.4
  • 6
    • 0025872518 scopus 로고
    • Effects of ice and recovery on maximal involuntary isometric torque production using electrical stimulation
    • Durst JW, Gohdes DD, Ward WK, Workman K, Bryan JM. Effects of ice and recovery on maximal involuntary isometric torque production using electrical stimulation. J Orthop Sports Phys Ther. 1991;13:240-248.
    • (1991) J Orthop Sports Phys Ther , vol.13 , pp. 240-248
    • Durst, J.W.1    Gohdes, D.D.2    Ward, W.K.3    Workman, K.4    Bryan, J.M.5
  • 7
    • 0025026157 scopus 로고
    • The effects of ice massage on an individual's pain tolerance level to electrical stimulation
    • Miller CR, Webers RL. The effects of ice massage on an individual's pain tolerance level to electrical stimulation. J Orthop Sports Phys Ther. 1990;12:105-109.
    • (1990) J Orthop Sports Phys Ther , vol.12 , pp. 105-109
    • Miller, C.R.1    Webers, R.L.2
  • 12
    • 0014067563 scopus 로고
    • Effects of cold application on maximal isometric contraction
    • McGown HL. Effects of cold application on maximal isometric contraction. Phys Ther. 1967;47:185-192.
    • (1967) Phys Ther , vol.47 , pp. 185-192
    • McGown, H.L.1
  • 13
    • 0017330563 scopus 로고
    • Influence of cold bath on maximum handgrip strength
    • Johnson J, Leider FE. Influence of cold bath on maximum handgrip strength. Percept Mot Skills. 1977;44:323-326.
    • (1977) Percept Mot Skills , vol.44 , pp. 323-326
    • Johnson, J.1    Leider, F.E.2
  • 14
    • 0018373794 scopus 로고
    • Isometric muscle contraction response during recovery from reduced intramuscular temperature
    • Oliver RA, Johnson DJ, Wheelhouse WW, Griffin PP. Isometric muscle contraction response during recovery from reduced intramuscular temperature. Arch Phys Med Rehabil. 1979;60:126-129.
    • (1979) Arch Phys Med Rehabil , vol.60 , pp. 126-129
    • Oliver, R.A.1    Johnson, D.J.2    Wheelhouse, W.W.3    Griffin, P.P.4
  • 17
    • 0018746422 scopus 로고
    • Comparison: Isometric muscle training and electric stimulation supplementing isometric muscle training in the recovery after knee ligament surgery
    • Erikson E, Haggmark T. Comparison: isometric muscle training and electric stimulation supplementing isometric muscle training in the recovery after knee ligament surgery. Am J Sports Med. 1982;7:169-171.
    • (1982) Am J Sports Med , vol.7 , pp. 169-171
    • Erikson, E.1    Haggmark, T.2
  • 20
    • 0023187465 scopus 로고
    • Comparison of voluntary and electrical stimulation induced torques at selected knee angles in male and female subjects
    • Kramer JF. Comparison of voluntary and electrical stimulation induced torques at selected knee angles in male and female subjects. Physiother Can. 1987;39:157-163.
    • (1987) Physiother Can , vol.39 , pp. 157-163
    • Kramer, J.F.1
  • 21
    • 0032892493 scopus 로고    scopus 로고
    • Peripheral nerve excitation and plantar flexion force elicited by electrical stimulation in males and females
    • Alon G, Kantor G, Smith GV. Peripheral nerve excitation and plantar flexion force elicited by electrical stimulation in males and females. J Orthop Sports Phys Ther. 1999;29:218-224.
    • (1999) J Orthop Sports Phys Ther , vol.29 , pp. 218-224
    • Alon, G.1    Kantor, G.2    Smith, G.V.3
  • 22
    • 0021875811 scopus 로고
    • Effects of waveform parameters on comfort during transcutaneous neuromuscular electrical stimulation
    • Bowman BR, Baker LL. Effects of waveform parameters on comfort during transcutaneous neuromuscular electrical stimulation. Ann Biomed Eng. 1985; 13:59-74.
    • (1985) Ann Biomed Eng , vol.13 , pp. 59-74
    • Bowman, B.R.1    Baker, L.L.2
  • 23
    • 0023033127 scopus 로고
    • Comparative comfort of three waveforms used in electrically eliciting quadriceps femoris contractions
    • Delitto A, Rose SJ. Comparative comfort of three waveforms used in electrically eliciting quadriceps femoris contractions. Phys Ther. 1986;66:1704-1707.
    • (1986) Phys Ther , vol.66 , pp. 1704-1707
    • Delitto, A.1    Rose, S.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.