메뉴 건너뛰기




Volumn 85, Issue 5, 2003, Pages 748-752

Influence of peg design and cement mantle thickness on pull-out strength of glenoid component pegs

Author keywords

[No Author keywords available]

Indexed keywords

BONE CEMENT; POLYETHYLENE;

EID: 0042670092     PISSN: 0301620X     EISSN: None     Source Type: Journal    
DOI: 10.1302/0301-620x.85b5.12580     Document Type: Article
Times cited : (35)

References (15)
  • 1
    • 0029991347 scopus 로고    scopus 로고
    • Complications of total shoulder-replacement arthroplasty
    • Wirth MA, Rockwood CA Jr. Complications of total shoulder-replacement arthroplasty. J Bone Joint Surg [Am] 1996;78-A:603-16.
    • (1996) J. Bone Joint Surg. [Am] , vol.78 A , pp. 603-616
    • Wirth, M.A.1    Rockwood C.A., Jr.2
  • 2
    • 0023879192 scopus 로고
    • Glenoid loosening in total shoulder arthroplasty: Association with rotator cuff deficiency
    • Franklin JL, Barrett WP, Jackins SE, Matsen FA 3rd. Glenoid loosening in total shoulder arthroplasty: association with rotator cuff deficiency. J Arthroplasty 1988;3:39-46.
    • (1988) J. Arthroplasty , vol.3 , pp. 39-46
    • Franklin, J.L.1    Barrett, W.P.2    Jackins, S.E.3    Matsen F.A. III4
  • 3
    • 0023216439 scopus 로고
    • Constrained arthroplasty of the shoulder
    • Post M. Constrained arthroplasty of the shoulder. Orthop Clin North Am 1987;18:455-62.
    • (1987) Orthop. Clin. North Am. , vol.18 , pp. 455-462
    • Post, M.1
  • 4
    • 0029900959 scopus 로고    scopus 로고
    • Modern cement technique and the survivorship of total shoulder arthroplasty
    • Norris BL, Lachiewicz PF. Modern cement technique and the survivorship of total shoulder arthroplasty. Clin Orthop 1996;328:76-85.
    • (1996) Clin. Orthop. , vol.328 , pp. 76-85
    • Norris, B.L.1    Lachiewicz, P.F.2
  • 6
    • 0034221718 scopus 로고    scopus 로고
    • Mechanical testing of shoulder prostheses and recommendations for glenoid design
    • Anglin C, Wyss UP, Pichora DR. Mechanical testing of shoulder prostheses and recommendations for glenoid design. J Shoulder Elbow Surg 2000;9:323-31.
    • (2000) J. Shoulder Elbow Surg. , vol.9 , pp. 323-331
    • Anglin, C.1    Wyss, U.P.2    Pichora, D.R.3
  • 7
    • 0023857036 scopus 로고
    • Biomechanical analysis of stability and fixation strength of total shoulder prostheses
    • Fukuda K, Chen CM, Cofield RH, Chao EY. Biomechanical analysis of stability and fixation strength of total shoulder prostheses. Orthopedics 1988;11:141-9.
    • (1988) Orthopedics , vol.11 , pp. 141-149
    • Fukuda, K.1    Chen, C.M.2    Cofield, R.H.3    Chao, E.Y.4
  • 8
    • 0041327611 scopus 로고    scopus 로고
    • Primary fixation of glenoid implants: An in vitro study
    • Walch G, Boileau P, eds Berlin: Springer
    • Lacaze F, Kempf KJ, Bonnomet F, Boutemy P, Colin F. Primary fixation of glenoid implants: an in vitro study. In: Walch G, Boileau P, eds. Shoulder arthroplasty. Berlin: Springer, 1999:141-6.
    • (1999) Shoulder Arthroplasty , pp. 141-146
    • Lacaze, F.1    Kempf, K.J.2    Bonnomet, F.3    Boutemy, P.4    Colin, F.5
  • 9
    • 0025514146 scopus 로고
    • The influence of fixation peg design on the shear stability of prosthetic implants
    • Giori NJ, Beaupre GS, Carter DR. The influence of fixation peg design on the shear stability of prosthetic implants. J Orthop Res 1990;8:892-8.
    • (1990) J. Orthop. Res. , vol.8 , pp. 892-898
    • Giori, N.J.1    Beaupre, G.S.2    Carter, D.R.3
  • 10
    • 0025147424 scopus 로고
    • Translation of the humeral head on the glenoid with passive glenohumeral motion
    • Harryman DTD, Sidles JA, Clark JM, et al. Translation of the humeral head on the glenoid with passive glenohumeral motion. J Bone Joint Surg [Am] 1990;72-A:1334-43.
    • (1990) J. Bone Joint Surg. [Am] , vol.72 A , pp. 1334-1343
    • Harryman, D.T.D.1    Sidles, J.A.2    Clark, J.M.3
  • 12
    • 0024468329 scopus 로고
    • Analysis of the pull-out strength of screws and pegs used to secure tibial components following total knee arthroplasty
    • Finlay JB, Harada I, Bourne RB, et al. Analysis of the pull-out strength of screws and pegs used to secure tibial components following total knee arthroplasty. Clin Orthop 1989;247:220-31.
    • (1989) Clin. Orthop. , vol.247 , pp. 220-231
    • Finlay, J.B.1    Harada, I.2    Bourne, R.B.3
  • 13
    • 0023856359 scopus 로고
    • The mechanical stability of various noncemented tibial components
    • Volz RG, Nisbet JK, Lee RW, McMurtry MG. The mechanical stability of various noncemented tibial components. Clin Orthop 1988;226:38-42.
    • (1988) Clin. Orthop. , vol.226 , pp. 38-42
    • Volz, R.G.1    Nisbet, J.K.2    Lee, R.W.3    McMurtry, M.G.4
  • 14
    • 0031172484 scopus 로고    scopus 로고
    • Properties of acrylic bone cement: State of the art review
    • Lewis G. Properties of acrylic bone cement: state of the art review. J Biomed Mater Res 1997;38:155-82.
    • (1997) J. Biomed. Mater. Res. , vol.38 , pp. 155-182
    • Lewis, G.1
  • 15
    • 0018609278 scopus 로고
    • The morphology of polymethylmethacrylate (PMMA) bone cement: Surface structures and causes of their origin
    • Willert HG, Mueller K, Semlitsch M. The morphology of polymethylmethacrylate (PMMA) bone cement: surface structures and causes of their origin. Arch Orthop Trauma Surg 1979;94:265-92.
    • (1979) Arch. Orthop. Trauma Surg. , vol.94 , pp. 265-292
    • Willert, H.G.1    Mueller, K.2    Semlitsch, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.