메뉴 건너뛰기




Volumn 15, Issue 3, 2003, Pages 107-112

Volume Management: Smart Variable Geometry Socket (SVGS) Technology for Lower-Limb Prostheses

Author keywords

Lower limb prosthesis; Socket fit; Socket retention; Volume management

Indexed keywords

ARTICLE; BIOMECHANICS; DYNAMICS; GEOMETRY; HUMAN; LEG AMPUTATION; LEG PROSTHESIS; TECHNOLOGY;

EID: 0042632645     PISSN: 10408800     EISSN: None     Source Type: Journal    
DOI: 10.1097/00008526-200307000-00011     Document Type: Article
Times cited : (38)

References (7)
  • 2
    • 0035705116 scopus 로고    scopus 로고
    • A comparison of trans-tibial amputee suction and vacuum socket conditions
    • Board WJ, Street GM, Caspers C. A comparison of trans-tibial amputee suction and vacuum socket conditions. Prosthet Orthot Int. 2001;25:202-209.
    • (2001) Prosthet Orthot Int , vol.25 , pp. 202-209
    • Board, W.J.1    Street, G.M.2    Caspers, C.3
  • 3
    • 0020050715 scopus 로고
    • Volume fluctuations in the residual limbs of lower limb amputees
    • Fernie GR, Holliday PJ. Volume fluctuations in the residual limbs of lower limb amputees. Arch Phys Med Rehabil. 1982;63: 162-165.
    • (1982) Arch Phys Med Rehabil , vol.63 , pp. 162-165
    • Fernie, G.R.1    Holliday, P.J.2
  • 4
    • 0035704462 scopus 로고    scopus 로고
    • Mechanical performance of inflatable inserts used in limb-prosthetics
    • Sanders JE, Cassisi DV. Mechanical performance of inflatable inserts used in limb-prosthetics. J Rehabil Res Dev. 2001;38: 365-374.
    • (2001) J Rehabil Res Dev , vol.38 , pp. 365-374
    • Sanders, J.E.1    Cassisi, D.V.2
  • 5
    • 0035704643 scopus 로고    scopus 로고
    • State-of-the-art research in lower-limb prosthetic biomechanics-socket interface
    • Mak AFT, Zhang M, Boone DA. State-of-the-art research in lower-limb prosthetic biomechanics-socket interface. J Rehabil Res Dev. 2001;38:161-173.
    • (2001) J Rehabil Res Dev , vol.38 , pp. 161-173
    • Mak, A.F.T.1    Zhang, M.2    Boone, D.A.3
  • 6
    • 0002412875 scopus 로고
    • The effect of pressure loading on the blood flow rate in human skin
    • Kenedi RM, Cowden JM, Scales JY, eds. London: Macmillan
    • Daly CH, Chimoskey JE, Holloway GA, Kennedy D. The effect of pressure loading on the blood flow rate in human skin. In: Kenedi RM, Cowden JM, Scales JY, eds. Bedsore Biomechanics. London: Macmillan; 1976:69-77.
    • (1976) Bedsore Biomechanics , pp. 69-77
    • Daly, C.H.1    Chimoskey, J.E.2    Holloway, G.A.3    Kennedy, D.4
  • 7
    • 0032053296 scopus 로고    scopus 로고
    • Clinical investigations of the pressure and shear stress on the transtibial residuum with prosthesis
    • Zhang M, Turner-Smith AR, Tanner A, Roberts VC. Clinical investigations of the pressure and shear stress on the transtibial residuum with prosthesis. Med Eng Phys. 1998;20: 188-198.
    • (1998) Med Eng Phys , vol.20 , pp. 188-198
    • Zhang, M.1    Turner-Smith, A.R.2    Tanner, A.3    Roberts, V.C.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.