메뉴 건너뛰기




Volumn 35, Issue 5, 2003, Pages 261-267

Lens epithelial cell migration between posterior capsule and intraocular lens with variously finished posterior optic edge and two haptic angulations

Author keywords

Biocompatible materials; Cataract; Intraocular lens; Lens capsule; Lens epithelial cells; Phacoemulsification; Posterior capsule opacification; Postoperative complications

Indexed keywords

ANIMAL EXPERIMENT; ARTICLE; CELL MIGRATION; CELL PROLIFERATION; CONTROLLED STUDY; HISTOLOGY; LENS CAPSULE; LENS EPITHELIUM; LENS IMPLANT; LENS IMPLANTATION; MICROPHOTOGRAPHY; NONHUMAN; POSTOPERATIVE PERIOD; PRIORITY JOURNAL; RABBIT; SCANNING ELECTRON MICROSCOPY; SCORING SYSTEM;

EID: 0042572516     PISSN: 00303747     EISSN: None     Source Type: Journal    
DOI: 10.1159/000072147     Document Type: Article
Times cited : (6)

References (23)
  • 1
    • 13144282668 scopus 로고    scopus 로고
    • A systematic overview of the incidence of posterior capsule opacification
    • Schaumberg DA, Dana MR, Christen WG, Glyn RJ: A systematic overview of the incidence of posterior capsule opacification. Ophthalmology 1998;105:1213-1221.
    • (1998) Ophthalmology , vol.105 , pp. 1213-1221
    • Schaumberg, D.A.1    Dana, M.R.2    Christen, W.G.3    Glyn, R.J.4
  • 2
    • 0025036126 scopus 로고
    • Histopathologic study of aftercataract in the pseudophakic rabbit eye using in-the-bag fixation
    • Ayaki M, Kyu N: Histopathologic study of aftercataract in the pseudophakic rabbit eye using in-the-bag fixation. Acta Soc Ophthalmol Jpn 1990;94:559-565.
    • (1990) Acta Soc Ophthalmol Jpn , vol.94 , pp. 559-565
    • Ayaki, M.1    Kyu, N.2
  • 3
    • 0035115046 scopus 로고    scopus 로고
    • Eradication of posterior capsule opacification: Documentation of a marked decrease in Nd:YAG laser posterior capsulotomy rates noted in an analysis of 5,416 pseudophakic human eyes obtained postmortem
    • Apple DJ, Peng Q, Visessook N, Werner L, Pandy SK, Escobar-Gomez M, Ram J, Auffarth GU: Eradication of posterior capsule opacification: Documentation of a marked decrease in Nd:YAG laser posterior capsulotomy rates noted in an analysis of 5,416 pseudophakic human eyes obtained postmortem. Ophthalmology 2001;108:505-518.
    • (2001) Ophthalmology , vol.108 , pp. 505-518
    • Apple, D.J.1    Peng, Q.2    Visessook, N.3    Werner, L.4    Pandy, S.K.5    Escobar-Gomez, M.6    Ram, J.7    Auffarth, G.U.8
  • 4
    • 0032881328 scopus 로고    scopus 로고
    • Effect of Tranilast eyedrops in preventing posterior capsule opacification: Preliminary report
    • Tobari I, Iwaki Y, Miyake K: Effect of Tranilast eyedrops in preventing posterior capsule opacification: Preliminary report. J Cataract Refract Surg 1999;25:1394-1399.
    • (1999) J Cataract Refract Surg , vol.25 , pp. 1394-1399
    • Tobari, I.1    Iwaki, Y.2    Miyake, K.3
  • 7
    • 0036172550 scopus 로고    scopus 로고
    • Inhibition of lens epithelial cell migration by an acrylic intraocular lens in vitro
    • Kurosaka D, Obasawa M, Kurosaka H, Nakamura K: Inhibition of lens epithelial cell migration by an acrylic intraocular lens in vitro. Ophthalmic Res 2002;34:29-37.
    • (2002) Ophthalmic Res , vol.34 , pp. 29-37
    • Kurosaka, D.1    Obasawa, M.2    Kurosaka, H.3    Nakamura, K.4
  • 8
    • 0029909183 scopus 로고    scopus 로고
    • Optic sharp edge or convexity: Comparison of effects on posterior capsular opacification
    • Nagata T, Watanabe I: Optic sharp edge or convexity: Comparison of effects on posterior capsular opacification. Jpn J Ophthalmol 1996;40:397-403.
    • (1996) Jpn J Ophthalmol , vol.40 , pp. 397-403
    • Nagata, T.1    Watanabe, I.2
  • 9
    • 0031890039 scopus 로고    scopus 로고
    • The inhibition of lens epithelial cell migration by a discontinuous capsular bend created by a band-shaped circular loop or a capsule-bending ring
    • Nishi O, Nishi K, Mano C, Ichihara M, Honda T: The inhibition of lens epithelial cell migration by a discontinuous capsular bend created by a band-shaped circular loop or a capsule-bending ring. Ophthalmic Surg Lasers 1998;29:119-125.
    • (1998) Ophthalmic Surg Lasers , vol.29 , pp. 119-125
    • Nishi, O.1    Nishi, K.2    Mano, C.3    Ichihara, M.4    Honda, T.5
  • 10
    • 0035319373 scopus 로고    scopus 로고
    • Effect of round-edged acrylic intraocular lenses on preventing posterior capsule opacification
    • Nishi O, Nishi K, Akura J, Nagata T: Effect of round-edged acrylic intraocular lenses on preventing posterior capsule opacification. J Cataract Refract Surg 2001;27:608-613.
    • (2001) J Cataract Refract Surg , vol.27 , pp. 608-613
    • Nishi, O.1    Nishi, K.2    Akura, J.3    Nagata, T.4
  • 14
    • 0036068597 scopus 로고    scopus 로고
    • Effect of haptic angulation on posterior capsule opacification in modern foldable lenses with a square, truncated optic edge
    • Schmidbauer JM, Escobar-Gomez M, Apple DJ, Peng Q, Arthur SN, Vargas LG: Effect of haptic angulation on posterior capsule opacification in modern foldable lenses with a square, truncated optic edge. J Cataract Refract Surg 2002;28:1251-1255.
    • (2002) J Cataract Refract Surg , vol.28 , pp. 1251-1255
    • Schmidbauer, J.M.1    Escobar-Gomez, M.2    Apple, D.J.3    Peng, Q.4    Arthur, S.N.5    Vargas, L.G.6
  • 15
    • 0023896693 scopus 로고
    • Surgical technique for experimental cataract extraction and intraocular lens implantation in the rabbit eye
    • Kyu N, Suzuki J, Ayaki M: Surgical technique for experimental cataract extraction and intraocular lens implantation in the rabbit eye. Folia Ophthalmol Jpn 1988;39:425-428.
    • (1988) Folia Ophthalmol Jpn , vol.39 , pp. 425-428
    • Kyu, N.1    Suzuki, J.2    Ayaki, M.3
  • 17
    • 0031802555 scopus 로고    scopus 로고
    • Adhesion of lens capsule to intraocular lenses of polymethyl-methacrylate, silicone and acrylic foldable materials: An experimental study
    • Oshika T, Nagata T, Ishii Y: Adhesion of lens capsule to intraocular lenses of polymethyl-methacrylate, silicone and acrylic foldable materials: An experimental study. Br J Ophthalmol 1998;82:549-553.
    • (1998) Br J Ophthalmol , vol.82 , pp. 549-553
    • Oshika, T.1    Nagata, T.2    Ishii, Y.3
  • 18
    • 0036192220 scopus 로고    scopus 로고
    • Speed of capsular bend formation at the optic edge of acrylic, silicone, and poly(methyl methacrylate) lenses
    • Nishi O, Nishi K, Akura J: Speed of capsular bend formation at the optic edge of acrylic, silicone, and poly(methyl methacrylate) lenses. J Cataract Refract Surg 2002;28:431-437.
    • (2002) J Cataract Refract Surg , vol.28 , pp. 431-437
    • Nishi, O.1    Nishi, K.2    Akura, J.3
  • 20
    • 0031711938 scopus 로고    scopus 로고
    • Capsule-bending ring for the prevention of capsular opacification: A preliminary report
    • Nishi O, Nishi K, Menapace R: Capsule-bending ring for the prevention of capsular opacification: A preliminary report. Ophthalmic Surg Lasers 1998;29:749-753.
    • (1998) Ophthalmic Surg Lasers , vol.29 , pp. 749-753
    • Nishi, O.1    Nishi, K.2    Menapace, R.3
  • 21
    • 0032622426 scopus 로고    scopus 로고
    • The effect of polymethylmethacrylate, silicone, and poly-acrylic intraocular lenses on posterior capsular opacification 3 years after cataract surgery
    • Hollick EJ, Spalton DJ, Ursell PG, Pande MV, Barman SA, Boyce JF, Tilling K: The effect of polymethylmethacrylate, silicone, and poly-acrylic intraocular lenses on posterior capsular opacification 3 years after cataract surgery. Ophthalmology 1999;106:49-54.
    • (1999) Ophthalmology , vol.106 , pp. 49-54
    • Hollick, E.J.1    Spalton, D.J.2    Ursell, P.G.3    Pande, M.V.4    Barman, S.A.5    Boyce, J.F.6    Tilling, K.7
  • 22
    • 0034858143 scopus 로고    scopus 로고
    • Neodymium:YAG capsulotomy rates following phacoemulsification with implantation of PMMA, silicone, and acrylic intraocular lenses
    • Ram J, Kaushik S, Brar GS, Gupta A: Neodymium:YAG capsulotomy rates following phacoemulsification with implantation of PMMA, silicone, and acrylic intraocular lenses. Ophthalmic Surg Lasers 2001;32:375-382.
    • (2001) Ophthalmic Surg Lasers , vol.32 , pp. 375-382
    • Ram, J.1    Kaushik, S.2    Brar, G.S.3    Gupta, A.4
  • 23
    • 0036062180 scopus 로고    scopus 로고
    • Three-year clinical comparison of 3-piece AcrySof and SI-40 silicone intraocular lenses
    • Daynes T, Spencer TS, Doan K, Mamalis N, Olson RJ: Three-year clinical comparison of 3-piece AcrySof and SI-40 silicone intraocular lenses. J Cataract Refract Surg 2002;28:1124-1129.
    • (2002) J Cataract Refract Surg , vol.28 , pp. 1124-1129
    • Daynes, T.1    Spencer, T.S.2    Doan, K.3    Mamalis, N.4    Olson, R.J.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.