-
1
-
-
0000952185
-
Observation of diffusion broadening of Rayleigh scattered light
-
Cummins, H.Z., Knable, N. and Yen, Y. (1964). Observation of diffusion broadening of Rayleigh scattered light. Phys. Rev. Lett., 12, 150-153.
-
(1964)
Phys. Rev. Lett.
, vol.12
, pp. 150-153
-
-
Cummins, H.Z.1
Knable, N.2
Yen, Y.3
-
2
-
-
33847446049
-
Stimulated optical radiation in ruby
-
Maiman, T.H. (1960). Stimulated optical radiation in ruby. Nature, 187, 493-494.
-
(1960)
Nature
, vol.187
, pp. 493-494
-
-
Maiman, T.H.1
-
3
-
-
0015428084
-
Laser Doppler measurements of blood flow in capillary tubes and retinal arteries
-
Riva, C., Ross, B. and Benedek, G.B. (1972). Laser Doppler measurements of blood flow in capillary tubes and retinal arteries. Invest. Opthalmol., 11, 936-944.
-
(1972)
Invest. Opthalmol.
, vol.11
, pp. 936-944
-
-
Riva, C.1
Ross, B.2
Benedek, G.B.3
-
4
-
-
0016630468
-
In vivo evaluation of microcirculation by coherent light scattering
-
Stern, M.D. (1975). In vivo evaluation of microcirculation by coherent light scattering. Nature, 254, 56-58.
-
(1975)
Nature
, vol.254
, pp. 56-58
-
-
Stern, M.D.1
-
5
-
-
0017733080
-
Laser Doppler measurement of cutaneous bloodflow
-
Holloway, G.A. and Watkins, D.W. (1977). Laser Doppler measurement of cutaneous bloodflow. J. Invest. Derm., 69, 306-309.
-
(1977)
J. Invest. Derm.
, vol.69
, pp. 306-309
-
-
Holloway, G.A.1
Watkins, D.W.2
-
6
-
-
0348200030
-
Continuous measurement of tissue blood flow by laser Doppler spectroscopy
-
Stern, M.D., Lappe, D.L., Bowen, P.D., Chimosky, J.E., Holloway, O.A., Keiser, H.R. and Bowman, R.L. (1977). Continuous measurement of tissue blood flow by laser Doppler spectroscopy. Am. J. Physiol., 232, F41-H448.
-
(1977)
Am. J. Physiol.
, vol.232
-
-
Stern, M.D.1
Lappe, D.L.2
Bowen, P.D.3
Chimosky, J.E.4
Holloway, O.A.5
Keiser, H.R.6
Bowman, R.L.7
-
7
-
-
0017904876
-
An instrument to measure cutaneous blood flow using the Doppler shift of laser light
-
Watkins, D. and Holloway, G.A. (1978). An instrument to measure cutaneous blood flow using the Doppler shift of laser light. IEEE Trans. Biomed. Eng., BME-25, 28-33
-
(1978)
IEEE Trans. Biomed. Eng.
, vol.BME-25
, pp. 28-33
-
-
Watkins, D.1
Holloway, G.A.2
-
8
-
-
0019230971
-
A new instrument for continuous measurement of tissue blood flow by light beating spectroscopy
-
Nilsson, G.E., Tenland, T. and Oberg, P.A. (1980a). A new instrument for continuous measurement of tissue blood flow by light beating spectroscopy. IEEE Trans. Biomed. Eng., BME-27, 12-19.
-
(1980)
IEEE Trans. Biomed. Eng.
, vol.BME-27
, pp. 12-19
-
-
Nilsson, G.E.1
Tenland, T.2
Oberg, P.A.3
-
9
-
-
0019225916
-
Evaluation of a laser Doppler flowmeter for measurement of tissue blood flow
-
Nilsson, G.E., Tenland, T. and Oberg, P.A. (1980b). Evaluation of a laser Doppler flowmeter for measurement of tissue blood flow. IEEE Trans. Biomed. Eng., BME-27, 597-604.
-
(1980)
IEEE Trans. Biomed. Eng.
, vol.BME-27
, pp. 597-604
-
-
Nilsson, G.E.1
Tenland, T.2
Oberg, P.A.3
-
10
-
-
0019583049
-
Model for laser Doppler measurements of blood flow in tissue
-
Bonner, R. and Nossal, R. (1981). Model for laser Doppler measurements of blood flow in tissue. Appl. Opt., 20, 2097-2107.
-
(1981)
Appl. Opt.
, vol.20
, pp. 2097-2107
-
-
Bonner, R.1
Nossal, R.2
-
11
-
-
0021015303
-
Comparison of two laser Doppler flowmeters for the monitoring of dermal blood flow
-
Fischer, J.C., Parker, P.M., Shaw, W.W. (1983). Comparison of two laser Doppler flowmeters for the monitoring of dermal blood flow. Microsurgery 4; 164-170.
-
(1983)
Microsurgery
, vol.4
, pp. 164-170
-
-
Fischer, J.C.1
Parker, P.M.2
Shaw, W.W.3
-
12
-
-
0023324399
-
Laser Doppler velocimetry: The problem of movement artefact
-
Newson, T.P., Obeid, A.N., Wolton, R.S., Boggett, D. and Rolfe, P. (1987). Laser Doppler velocimetry: the problem of movement artefact. J. Biomed. Eng., 9, 169-172.
-
(1987)
J. Biomed. Eng.
, vol.9
, pp. 169-172
-
-
Newson, T.P.1
Obeid, A.N.2
Wolton, R.S.3
Boggett, D.4
Rolfe, P.5
-
13
-
-
8944246794
-
Microregional blood flow in murine and human tumours assessed using laser Doppler microprobes
-
NO- S XXVII
-
Hill, S.A., Pigott, K.H., Saunders, M.I., Powell, M.E.B., Arnold, S., Obeid, A.,Ward, G., Leahy, M., Hoskin, P.J., Chaplin, D.J., 1996. Microregional blood flow in murine and human tumours assessed using laser Doppler microprobes, British Journal of Cancer, 74, NO- S XXVII, S260-S263.
-
(1996)
British Journal of Cancer
, vol.74
-
-
Hill, S.A.1
Pigott, K.H.2
Saunders, M.I.3
Powell, M.E.B.4
Arnold, S.5
Obeid, A.6
Ward, G.7
Leahy, M.8
Hoskin, P.J.9
Chaplin, D.J.10
-
14
-
-
0027573492
-
Laser Doppler perfusion imaging by dynamic light scattering
-
Wårdell, K., Jakobsson, A. and Nilsson, G.E., 1993. Laser Doppler perfusion imaging by dynamic light scattering, IEEE Trans. Biomed. Eng., BME, 40, 309-316.
-
(1993)
IEEE Trans. Biomed. Eng., BME
, vol.40
, pp. 309-316
-
-
Wårdell, K.1
Jakobsson, A.2
Nilsson, G.E.3
-
15
-
-
0032790980
-
Principles and Practice of the laser Doppler perfusion technique
-
Leahy, M.J., de Mul, F.F.M, Nilsson, G.E., and Maniewski, R., (1999). Principles and Practice of the laser Doppler perfusion technique. Eur. Soc. Eng. & Med. Technology and Health Care, 7, 143-162.
-
(1999)
Eur. Soc. Eng. & Med. Technology and Health Care
, vol.7
, pp. 143-162
-
-
Leahy, M.J.1
De Mul, F.F.M.2
Nilsson, G.E.3
Maniewski, R.4
-
17
-
-
0022146695
-
Detection properties of an optical fiber probe for laser speckle velocimetry
-
Fujii, H., Asakura, T., Okamoto, T., (1985). Detection properties of an optical fiber probe for laser speckle velocimetry. Optics Communications, 55, no. 6.
-
(1985)
Optics Communications
, vol.55
, Issue.6
-
-
Fujii, H.1
Asakura, T.2
Okamoto, T.3
-
18
-
-
0027591676
-
Prediction of sampling depth and photon pathlength in laser Doppler flowmetry
-
Jakobsson, A. and Nilsson, G.E. (1993) Prediction of sampling depth and photon pathlength in laser Doppler flowmetry, Med Biol Eng. & Comput, 31, 301-307.
-
(1993)
Med Biol Eng. & Comput
, vol.31
, pp. 301-307
-
-
Jakobsson, A.1
Nilsson, G.E.2
-
19
-
-
0026626319
-
Tissue perfusion and imaging by coherent light scattering
-
BIOOPTTCS (Ed-Scheggi & Soares)
-
Nilsson, G.E., Jakobsson, A. and Wårdell, K. (1992) Tissue perfusion and imaging by coherent light scattering, in BIOOPTTCS (Ed-Scheggi & Soares), SPIE Vol. 1524, p 90-109.
-
(1992)
SPIE
, vol.1524
, pp. 90-109
-
-
Nilsson, G.E.1
Jakobsson, A.2
Wårdell, K.3
-
20
-
-
0028458916
-
Laser Doppler blood flowmetry using two wavelngths: Monte Carlo simulations and measurements
-
Koelink M. H., de Mul F. F. M., Greve J., Graaf R., DasseL A. C. M., Aarnoudse J. G., (1994). Laser Doppler blood flowmetry using two wavelngths: Monte Carlo simulations and measurements. Applied Optics 33:16, 3549-3558.
-
(1994)
Applied Optics
, vol.33
, Issue.16
, pp. 3549-3558
-
-
Koelink, M.H.1
De Mul, F.F.M.2
Greve, J.3
Graaf, R.4
DasseL, A.C.M.5
Aarnoudse, J.G.6
-
21
-
-
0026297745
-
Estimation of sampling depth in laser Doppler flowmetry based on a Monte Carlo model
-
Jakobsson, A, Nilsson, G. E., (1991). Estimation of sampling depth in laser Doppler flowmetry based on a Monte Carlo model. Proceedings of the Annual Conference on Engineering in Medicine and Biology. Vol.13, No.4, 1753-1754.
-
(1991)
Proceedings of the Annual Conference on Engineering in Medicine and Biology
, vol.13
, Issue.4
, pp. 1753-1754
-
-
Jakobsson, A.1
Nilsson, G.E.2
-
22
-
-
0038125241
-
Guidelines for measurement of contaneous blood flow by laser Doppler flowmetry
-
Bircher A., de Boer E.M., Agner T., Wahlberg J.E., Serup J., (1993), Guidelines for measurement of contaneous blood flow by laser Doppler flowmetry, Contact Dermatitis, 28, 1-8
-
(1993)
Contact Dermatitis
, vol.28
, pp. 1-8
-
-
Bircher, A.1
De Boer, E.M.2
Agner, T.3
Wahlberg, J.E.4
Serup, J.5
-
23
-
-
0041896080
-
Evaluation of Laser-Doppler flowmetry in the assessment of blood flow in the feline small intestine
-
Ahn H. et al. (1984) Evaluation of Laser-Doppler flowmetry in the assessment of blood flow in the feline small intestine. Int. J. Microcirc.: Clin. Exp. 3, 478.
-
(1984)
Int. J. Microcirc.: Clin. Exp.
, vol.3
, pp. 478
-
-
Ahn, H.1
-
24
-
-
0041896080
-
Laser-Doppler flowmetry in the assessment of intestinal blood flow in man
-
Lindhagen J. et al., (1984) Laser-Doppler flowmetry in the assessment of intestinal blood flow in man. Int. J. Microcirc.: Clin Exp., 3, 478.
-
(1984)
Int. J. Microcirc.: Clin Exp.
, vol.3
, pp. 478
-
-
Lindhagen, J.1
-
25
-
-
0022578588
-
New methods for whole blood oximetry
-
Schmitt J.M., Mihm F.G., Meindl, J.D., (1986). New methods for whole blood oximetry, Annals of Biomedical Engineering, 14, 35-52.
-
(1986)
Annals of Biomedical Engineering
, vol.14
, pp. 35-52
-
-
Schmitt, J.M.1
Mihm, F.G.2
Meindl, J.D.3
-
26
-
-
0018028169
-
Effects of asphericity on single particle scattering
-
1978
-
Latimer P., Brunsting A., Pyle B.E., Moore C., (1978). Effects of asphericity on single particle scattering, Applied Optics, Vol. 17, no. 19, 1978, 3152-3158.
-
(1978)
Applied Optics
, vol.17
, Issue.19
, pp. 3152-3158
-
-
Latimer, P.1
Brunsting, A.2
Pyle, B.E.3
Moore, C.4
-
27
-
-
0005397240
-
A calibration standard for laser-Doppler perfusion measurements
-
Liebert, A., Leahy, M., and Maniewski, R., (1995). A calibration standard for laser-Doppler perfusion Measurements, Rev. Sci. Instr. 66 (11), 5169-73.
-
(1995)
Rev. Sci. Instr.
, vol.66
, Issue.11
, pp. 5169-5173
-
-
Liebert, A.1
Leahy, M.2
Maniewski, R.3
-
28
-
-
84887196567
-
Laser Doppler Velocimetry and Monte Carlo simulations on models for blood perfusion in tissue
-
De Mul, F.F.M., Koelink, M.H., Kok, M.L., Harmsma, P.J., Greve J. et al., (1995). Laser Doppler Velocimetry and Monte Carlo simulations on models for blood perfusion in tissue, Appl.Optics., 34 (28), 6595-6611.
-
(1995)
Appl. Optics.
, vol.34
, Issue.28
, pp. 6595-6611
-
-
De Mul, F.F.M.1
Koelink, M.H.2
Kok, M.L.3
Harmsma, P.J.4
Greve, J.5
-
29
-
-
0023324399
-
Laser Doppler velocimetry: The problem of movement artefact
-
Newson, T.P., Obeid, A.N., Wolton, R.S., Boggett, D. and Rolfe, P. (1987). Laser Doppler velocimetry: the problem of movement artefact. J. Biomed. Eng., 9, 169-172.
-
(1987)
J. Biomed. Eng.
, vol.9
, pp. 169-172
-
-
Newson, T.P.1
Obeid, A.N.2
Wolton, R.S.3
Boggett, D.4
Rolfe, P.5
-
30
-
-
0021493797
-
Mini laser Doppler (blood) flow monitor with diode laser source and detection integrated in the probe
-
De Mul, F.F.M., Van Spijker, J., Van der Plas, D., Greve, J., Aarndoudse, J.G. and Smits, T.M. (1984). Mini laser Doppler (blood) flow monitor with diode laser source and detection integrated in the probe. Appl. Optics, 23, 2970-2973.
-
(1984)
Appl. Optics
, vol.23
, pp. 2970-2973
-
-
De Mul, F.F.M.1
Van Spijker, J.2
Van der Plas, D.3
Greve, J.4
Aarndoudse, J.G.5
Smits, T.M.6
-
31
-
-
0029114406
-
Haemorrhage during anaesthesia and surgery: Continuous measurement of microcirculatory blood flow in the kidney, liver, skin and skeletal muscle
-
Erni, D., Banic, A., Wheatley, A.M., Sigurdsson, G.H. (1995). Haemorrhage during anaesthesia and surgery: Continuous measurement of microcirculatory blood flow in the kidney, liver, skin and skeletal muscle. European Journal of Anaesthesiology, Vol. 12, No.4, 423-429.
-
(1995)
European Journal of Anaesthesiology
, vol.12
, Issue.4
, pp. 423-429
-
-
Erni, D.1
Banic, A.2
Wheatley, A.M.3
Sigurdsson, G.H.4
-
32
-
-
0021392297
-
Measurement of skin blood flow
-
March 1984
-
Payne, P.A., (1984). Measurement of skin blood flow, Electronics & Power, March 1984, p219-221.
-
(1984)
Electronics & Power
, pp. 219-221
-
-
Payne, P.A.1
-
33
-
-
0015904601
-
The thickness of the epidermis
-
Whitton, J. T., and Everall, J. D., (1973). The thickness of the epidermis. Brit. J. Derm., 89, p467.
-
(1973)
Brit. J. Derm.
, vol.89
, pp. 467
-
-
Whitton, J.T.1
Everall, J.D.2
-
34
-
-
0022271568
-
A double wavelength laser Doppler system to investigate skin microcirculation
-
Duteil L., Bernengo, J. C., and Schalla, W., (1985). A Double Wavelength Laser Doppler System to Investigate Skin Microcirculation', Trans. Biomed. Eng. BME 32: 6, p439-447.
-
(1985)
Trans. Biomed. Eng. BME
, vol.32
, Issue.6
, pp. 439-447
-
-
Duteil, L.1
Bernengo, J.C.2
Schalla, W.3
-
35
-
-
0025885894
-
Depth dependent laser Doppler perfusion measurements
-
Laser Diagnostics of Biological Molecules and Living Cells - Linear and Nonlinear Methods
-
Koelink, M.H., de Mul, F.F.M., Greve, J., Graaff, R., Dassel, A.C.M., Aarnoudse, J.G., (1991). Depth dependent laser Doppler perfusion measurements. Theory and Instrumentation. VO-1403, NO-1: 347-349. Laser Diagnostics of Biological Molecules and Living Cells - Linear and Nonlinear Methods.
-
(1991)
Theory and Instrumentation
, vol.1403
, Issue.1
, pp. 347-349
-
-
Koelink, M.H.1
De Mul, F.F.M.2
Greve, J.3
Graaff, R.4
Dassel, A.C.M.5
Aarnoudse, J.G.6
-
36
-
-
0024043313
-
Depth discrimination in laser Doppler skin blood flow measurement using different lasers
-
Obeid A. N., Boggett D., Dougherty G., Barnett N. J., Rolfe, P., (1988). Depth discrimination in laser Doppler skin blood flow measurement using different lasers. Med. & Biol. Eng. & Comput. 26, 415-419.
-
(1988)
Med. & Biol. Eng. & Comput.
, vol.26
, pp. 415-419
-
-
Obeid, A.N.1
Boggett, D.2
Dougherty, G.3
Barnett, N.J.4
Rolfe, P.5
-
37
-
-
0027673677
-
Biological zero of laser Doppler fluxmetry: Microcirculatory correlates in the hamster cheek pouch during flow and no flow conditions
-
Colantuoni, A., Bertuglia, S. and Intaglietta, M. (1993) Biological zero of laser Doppler fluxmetry: microcirculatory correlates in the hamster cheek pouch during flow and no flow conditions, Int J Microcirc Clin Exp, 13(2), 125-36.
-
(1993)
Int J Microcirc Clin Exp
, vol.13
, Issue.2
, pp. 125-136
-
-
Colantuoni, A.1
Bertuglia, S.2
Intaglietta, M.3
-
38
-
-
0020900381
-
Rhythmical variations in human skin blood flow
-
Salerud, E.G., Tenland, T., Nilsson, G.E. and Öberg, P-Å. (1983) Rhythmical variations in human skin blood flow. Int J Microcirc: Clin & Exp, 2, 91-102.
-
(1983)
Int J Microcirc: Clin & Exp
, vol.2
, pp. 91-102
-
-
Salerud, E.G.1
Tenland, T.2
Nilsson, G.E.3
Öberg, P.-Å.4
-
39
-
-
0020909943
-
Spatial and temporal variations in human skin blood flow
-
Tenland, T., Salerud, G.E., Nilsson, G.E. and Öberg, P.Å. (1983) Spatial and temporal variations in human skin blood flow. Int J Microcirc: Clin & Exp, 2, 81-90.
-
(1983)
Int J Microcirc: Clin & Exp
, vol.2
, pp. 81-90
-
-
Tenland, T.1
Salerud, G.E.2
Nilsson, G.E.3
Öberg, P.Å.4
-
40
-
-
0027131654
-
Fundamental patterns and characteristics of the laser-Doppler skin blood flow waves recorded from the finger or toe
-
Dec
-
Kano, T., Shimoda, O., Higashi, K., Sadanaga, M. and Sakamoto, M. (1993) Fundamental patterns and characteristics of the laser-Doppler skin blood flow waves recorded from the finger or toe. J Auton Nerv Syst, Dec, 45(3); p 191-9.
-
(1993)
J Auton Nerv Syst
, vol.45
, Issue.3
, pp. 191-199
-
-
Kano, T.1
Shimoda, O.2
Higashi, K.3
Sadanaga, M.4
Sakamoto, M.5
-
41
-
-
0028602912
-
Waveform analysis of laser Doppler signals from normal and diabetic feet
-
Smith, T., Thomas, S., Torgersen, T., Holden, M. and Kohman, L.A., (1994). Waveform analysis of laser Doppler signals from normal and diabetic feet. IEEE Symposium on Computer -Based Medical Systems, 77-81.
-
(1994)
IEEE Symposium on Computer -Based Medical Systems
, pp. 77-81
-
-
Smith, T.1
Thomas, S.2
Torgersen, T.3
Holden, M.4
Kohman, L.A.5
-
42
-
-
0024997310
-
Correlation of laser Doppler wave patterns with underlying microvascular anatomy
-
Braverman, I.M., Keh, A. and Goldminz, D., (1990). Correlation of laser Doppler wave patterns with underlying microvascular anatomy, J Invest Dermatol 95, 283-286.
-
(1990)
J Invest Dermatol
, vol.95
, pp. 283-286
-
-
Braverman, I.M.1
Keh, A.2
Goldminz, D.3
-
43
-
-
0028102380
-
Spatial heterogeneity in normal skin perfusion recorded with laser Doppler imaging and flowmetry
-
Wårdell, K., Braverman, LM., Silverman, D.G. and Nilsson, G.E., (1994). Spatial heterogeneity in normal skin perfusion recorded with laser Doppler imaging and flowmetry, Microvascular Research, Vol. 48, No.1, 26-38.
-
(1994)
Microvascular Research
, vol.48
, Issue.1
, pp. 26-38
-
-
Wårdell, K.1
Braverman, L.M.2
Silverman, D.G.3
Nilsson, G.E.4
-
44
-
-
0022749877
-
Integrating probe for tissue laser Doppler flowmeters
-
Salerud, E.G. and Nilsson, G.E., (1986). Integrating probe for tissue laser Doppler flowmeters. Med & Biol Eng. & Comput, 24, 415-419.
-
(1986)
Med & Biol Eng. & Comput
, vol.24
, pp. 415-419
-
-
Salerud, E.G.1
Nilsson, G.E.2
-
45
-
-
0027573492
-
Laser Doppler perfusion imaging by dynamic light scattering
-
Wårdell, K., Jakobsson, A. and Nilsson, G.E. (1993) Laser Doppler perfusion imaging by dynamic light scattering, IEEE Trans. on BME, 40, 309-316.
-
(1993)
IEEE Trans. on BME
, vol.40
, pp. 309-316
-
-
Wårdell, K.1
Jakobsson, A.2
Nilsson, G.E.3
-
46
-
-
0027408992
-
The cutaneous vascular axon reflex in humans characterized by laser Doppler perfusion imaging
-
Wårdell, K., Naver, H.K., Nilsson, G.E. and Wallin, B.G. (1993) The cutaneous vascular axon reflex in humans characterized by laser Doppler perfusion imaging, J Physiol, 460, 185-99.
-
(1993)
J Physiol
, vol.460
, pp. 185-199
-
-
Wårdell, K.1
Naver, H.K.2
Nilsson, G.E.3
Wallin, B.G.4
-
47
-
-
0028314849
-
Changes in skin circulation after insertion of a microdialysis probe visualised by laser Doppler perfusion imaging
-
Anderson, C., Andersson, T. and Wårdell, K., (1994). Changes in skin circulation after insertion of a microdialysis probe visualised by laser Doppler perfusion imaging, J Invest Derm, Vol. 102, No.5, 807-811.
-
(1994)
J Invest Derm
, vol.102
, Issue.5
, pp. 807-811
-
-
Anderson, C.1
Andersson, T.2
Wårdell, K.3
-
48
-
-
0026534559
-
Evaluation of port wine stain perfusion by laser Doppler imaging and thermography before and after argon laser treatment
-
Troilius, A., Wårdell, K., Bornmyr, S., Nilsson and Ljunggren, B. (1992), Evaluation of port wine stain perfusion by laser Doppler imaging and thermography before and after argon laser treatment, Acta Derm Ven, 72, 6-10.
-
(1992)
Acta Derm Ven
, vol.72
, pp. 6-10
-
-
Troilius, A.1
Wårdell, K.2
Bornmyr, S.3
Nilsson4
Ljunggren, B.5
-
49
-
-
0027490760
-
A preliminary assessment of laser Doppler perfusion imaging in human skin using tuberculin reaction as a model
-
Harrison, D.K., Abbot, N.C., Swanson Beck, J. and McCollum, P.T. (1993) A preliminary assessment of laser Doppler perfusion imaging in human skin using tuberculin reaction as a model, Phys Med Biol, 14, 241-252
-
(1993)
Phys Med Biol
, vol.14
, pp. 241-252
-
-
Harrison, D.K.1
Abbot, N.C.2
Swanson Beck, J.3
McCollum, P.T.4
-
50
-
-
0028036381
-
Comparison of laser Doppler perfusion imaging, laser Doppler flowmetry, and thermographic imaging for the assessment of blood flow in human skin
-
Jan
-
Seifalian, A.M., Stansby, G., Jackson, A., Howell, K. and Hamilton, G. (1994) Comparison of laser Doppler perfusion imaging, laser Doppler flowmetry, and thermographic imaging for the assessment of blood flow in human skin, Eur J Vasc Surg, Jan, 8(1), 65-9
-
(1994)
Eur J Vasc Surg
, vol.8
, Issue.1
, pp. 65-69
-
-
Seifalian, A.M.1
Stansby, G.2
Jackson, A.3
Howell, K.4
Hamilton, G.5
-
51
-
-
0027471837
-
Acute inflammation in the rat knee joint attenuates sympathetic vasoconstriction but enhances neuropeptide-mediated vasodilatation assessed by laser Doppler perfusion imaging
-
Lam, F.Y. and Ferrell, W.R. (1993), Acute inflammation in the rat knee joint attenuates sympathetic vasoconstriction but enhances neuropeptide-mediated vasodilatation assessed by laser Doppler perfusion imaging, Neuroscience, 52, 443-449.
-
(1993)
Neuroscience
, vol.52
, pp. 443-449
-
-
Lam, F.Y.1
Ferrell, W.R.2
-
52
-
-
0042898268
-
A new technique for intra-operative assessment of regional myocardial perfusion when using arterial grafts
-
Aug 21-23, Tromsö, Norway, 1992
-
Hermansson, U., Ahn, H.C., Nilsson, G.E. & Wårdell, K. (1992) A new technique for intra-operative assessment of regional myocardial perfusion when using arterial grafts, The 41st Annual Meeting of the Scandinavian Association for Thoracic and Cardiovascular Surgery, Aug 21-23, Tromsö, Norway, 1992.
-
(1992)
The 41st Annual Meeting of the Scandinavian Association for Thoracic and Cardiovascular Surgery
-
-
Hermansson, U.1
Ahn, H.C.2
Nilsson, G.E.3
Wårdell, K.4
-
53
-
-
0030037109
-
Toe blood pressure measurements with laser Doppler
-
Pahlsson H I, Wahlberg E, Wei S Z, Jorneskog G, Swedenborg J, Olofsson P, Fagrell B. Toe Blood Pressure Measurements with Laser Doppler. J Vasc Investigation, 2(2), 82-86, 1996.
-
(1996)
J Vasc Investigation
, vol.2
, Issue.2
, pp. 82-86
-
-
Pahlsson, H.I.1
Wahlberg, E.2
Wei, S.Z.3
Jorneskog, G.4
Swedenborg, J.5
Olofsson, P.6
Fagrell, B.7
-
55
-
-
0034980373
-
Measurement of tumor oxygenation: In vivo comparison of a luminescence fiber-optic sensor and a polarographic electrode in the p22 tumor
-
Measurement of tumor oxygenation: in vivo comparison of a luminescence fiber-optic sensor and a polarographic electrode in the p22 tumor. Rad. Res. 155, 837-46.
-
Rad. Res.
, vol.155
, pp. 837-846
-
-
-
56
-
-
0036507635
-
Laser Doppler perfusion imaging with a complimentary metal oxide semiconductor image sensor
-
March 1 2002
-
Serov A., Steenbergen W., de Mul F., (2002). Laser Doppler perfusion imaging with a complimentary metal oxide semiconductor image sensor. Optics letters, 27 (5): 300-302 March 1 2002.
-
(2002)
Optics Letters
, vol.27
, Issue.5
, pp. 300-302
-
-
Serov, A.1
Steenbergen, W.2
De Mul, F.3
|