메뉴 건너뛰기




Volumn 163, Issue 2, 2003, Pages 277-287

Retrospective intra-scan motion correction

Author keywords

Image reconstruction; Intra scan motion correction; Motion artefacts; Post processing

Indexed keywords

BRAIN; IMAGE RECONSTRUCTION; MONTE CARLO METHODS; MOTION ESTIMATION; SCANNING; SIGNAL TO NOISE RATIO;

EID: 0042530529     PISSN: 10907807     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1090-7807(03)00154-X     Document Type: Article
Times cited : (6)

References (39)
  • 1
    • 0026374738 scopus 로고
    • An improved algorithm for 2-D translational motion artifact correction
    • Hedley M., Yan H., Rosenfeld D. An improved algorithm for 2-D translational motion artifact correction. IEEE Trans. Med. Imaging. 10:1991;548-553.
    • (1991) IEEE Trans. Med. Imaging , vol.10 , pp. 548-553
    • Hedley, M.1    Yan, H.2    Rosenfeld, D.3
  • 2
    • 0026117505 scopus 로고
    • Motion artifact correction in MRI using generalized projections
    • Hedley M., Yan H., Rosenfeld D. Motion artifact correction in MRI using generalized projections. IEEE Trans. Med. Imaging. 10:1991;40-46.
    • (1991) IEEE Trans. Med. Imaging , vol.10 , pp. 40-46
    • Hedley, M.1    Yan, H.2    Rosenfeld, D.3
  • 3
    • 0029373544 scopus 로고
    • An improved method for MRI artifact correction due to translational motion in the imaging plane
    • Zoroofi R.A., Sato Y., Tamura S., Naito H. An improved method for MRI artifact correction due to translational motion in the imaging plane. IEEE Trans. Med. Imaging. 14:1995;471-479.
    • (1995) IEEE Trans. Med. Imaging , vol.14 , pp. 471-479
    • Zoroofi, R.A.1    Sato, Y.2    Tamura, S.3    Naito, H.4
  • 4
    • 0030816656 scopus 로고    scopus 로고
    • Cancellation of motion artifact in MRI due to 2D rigid translation motion
    • Tang L., Ohya M., Sato Y., Naito H., Harada K., Tamura S. Cancellation of motion artifact in MRI due to 2D rigid translation motion. Comput. Biol. Med. 27:1997;211-222.
    • (1997) Comput. Biol. Med. , vol.27 , pp. 211-222
    • Tang, L.1    Ohya, M.2    Sato, Y.3    Naito, H.4    Harada, K.5    Tamura, S.6
  • 5
    • 0028944350 scopus 로고
    • Spatial-frequency-tuner markers and adaptative correction for rotational motion
    • Korin H.W., Felmee J.P., Riederer S.J., Ehman R.L. Spatial-frequency-tuner markers and adaptative correction for rotational motion. Magn. Reson. Med. 33:1995;663-669.
    • (1995) Magn. Reson. Med. , vol.33 , pp. 663-669
    • Korin, H.W.1    Felmee, J.P.2    Riederer, S.J.3    Ehman, R.L.4
  • 8
    • 0036136070 scopus 로고    scopus 로고
    • Spherical navigator echoes for full 3D rigid body motion measurement in MRI
    • Welch E.B., Manduca A., Grimm R.C., Ward H.A., Jack C.R. Spherical navigator echoes for full 3D rigid body motion measurement in MRI. Magn. Reson. Med. 47:2002;32-41.
    • (2002) Magn. Reson. Med. , vol.47 , pp. 32-41
    • Welch, E.B.1    Manduca, A.2    Grimm, R.C.3    Ward, H.A.4    Jack, C.R.5
  • 9
    • 0030395756 scopus 로고    scopus 로고
    • MRI artifact cancellation due to rigid motion in the imaging plane
    • Zoroofi R.A., Sato Y., Tamura S., Naito H. MRI artifact cancellation due to rigid motion in the imaging plane. IEEE Trans. Med. Imaging. 15:1996;768-784.
    • (1996) IEEE Trans. Med. Imaging , vol.15 , pp. 768-784
    • Zoroofi, R.A.1    Sato, Y.2    Tamura, S.3    Naito, H.4
  • 10
    • 0031283439 scopus 로고    scopus 로고
    • Automatic correction of motion artifacts in Magnetic Resonance images using an entropy focus criterion
    • Atkinson D., Hill D.L.G., Stoyle P.N.R., Summers P.E., Keevil S.F. Automatic correction of motion artifacts in Magnetic Resonance images using an entropy focus criterion. IEEE Trans. Med. Imaging. 16:1997;903-910.
    • (1997) IEEE Trans. Med. Imaging , vol.16 , pp. 903-910
    • Atkinson, D.1    Hill, D.L.G.2    Stoyle, P.N.R.3    Summers, P.E.4    Keevil, S.F.5
  • 11
    • 0032034226 scopus 로고    scopus 로고
    • An improved algorithm for rotational motion artifact suppression in MRI
    • Weerasinghe C., Yan H. An improved algorithm for rotational motion artifact suppression in MRI. IEEE Trans. Med. Imaging. 17:1998;310-317.
    • (1998) IEEE Trans. Med. Imaging , vol.17 , pp. 310-317
    • Weerasinghe, C.1    Yan, H.2
  • 12
    • 0011325577 scopus 로고    scopus 로고
    • Birkhäuser, Basel, Ch. 16, J.J. Benedetto, P.J.S.G. Ferreira (Eds.), Reconstruction of MRI Images from Non-Uniform Sampling: Application to Intrascan Motion Correction in Functional MRI
    • M. Bourgeois, F.T.A.W. Wajer, D. van Ormondt, D. Graveron-Demilly, In Book: Modern Sampling Theory: Mathematics and Applications, Birkhäuser, Basel, 2001, Ch. 16, J.J. Benedetto, P.J.S.G. Ferreira (Eds.), Reconstruction of MRI Images from Non-Uniform Sampling: Application to Intrascan Motion Correction in Functional MRI, pp. 343-362.
    • (2001) Book: Modern Sampling Theory: Mathematics and Applications , pp. 343-362
    • Bourgeois, M.1    Wajer, F.T.A.W.2    Van Ormondt, D.3    Graveron-Demilly, D.4
  • 13
    • 0042188758 scopus 로고    scopus 로고
    • Marcel Dekker, New York, Ch. 5, H. Yan (Ed.), Rotational Motion Artifact Correction based on Fuzzy Projection onto Convex Sets
    • C. Weerasinghe, L. Jan, H. Yan, In Book: Signal Processing for Magnetic Resonance Imaging and Spectroscopy, Marcel Dekker, New York, 2002, Ch. 5, H. Yan (Ed.), Rotational Motion Artifact Correction based on Fuzzy Projection onto Convex Sets, pp. 125-166.
    • (2002) Book: Signal Processing for Magnetic Resonance Imaging and Spectroscopy , pp. 125-166
    • Weerasinghe, C.1    Jan, L.2    Yan, H.3
  • 14
    • 0029155699 scopus 로고
    • Correction of motional artifacts in diffusion-weighted images using a reference phase map
    • Ulug A.M., Baker P.B., van Zijl P.C.M. Correction of motional artifacts in diffusion-weighted images using a reference phase map. Magn. Reson. Med. 34:1995;476-480.
    • (1995) Magn. Reson. Med. , vol.34 , pp. 476-480
    • Ulug, A.M.1    Baker, P.B.2    Van Zijl, P.C.M.3
  • 20
    • 0026171305 scopus 로고
    • A modified Gerchberg-Saxton algorithm for one-dimensional motion artifact correction in MRI
    • Hedley M., Yan H., Rosenfeld D. A modified Gerchberg-Saxton algorithm for one-dimensional motion artifact correction in MRI. IEEE Trans. Signal Process. 39:1991;1428-1433.
    • (1991) IEEE Trans. Signal Process. , vol.39 , pp. 1428-1433
    • Hedley, M.1    Yan, H.2    Rosenfeld, D.3
  • 21
    • 0029378348 scopus 로고
    • A gridding method for image reconstruction by Fourier transformation
    • Schomberg H., Timmer J. A gridding method for image reconstruction by Fourier transformation. IEEE Trans. Med. Imaging. 14:1995;596-607.
    • (1995) IEEE Trans. Med. Imaging , vol.14 , pp. 596-607
    • Schomberg, H.1    Timmer, J.2
  • 28
    • 0011330364 scopus 로고    scopus 로고
    • Ph.D. Thesis, Delft University of Technology - TUD, Delft, The Netherlands
    • F.T.A.W. Wajer, Non-Cartesian MRI scan time reduction through sparse sampling, Ph.D. Thesis, Delft University of Technology - TUD, Delft, The Netherlands. Available from < http://www.library.tudelft.nl/dissertations/> (2001).
    • (2001) Non-Cartesian MRI Scan Time Reduction Through Sparse Sampling
    • Wajer, F.T.A.W.1
  • 29
    • 0002438242 scopus 로고
    • Ringing artefact reduction by an efficient likelihood improvement method
    • M. Fuderer, Ringing artefact reduction by an efficient likelihood improvement method, in: Proc. SPIE, vol. 1137, 1989, pp. 84-90.
    • (1989) Proc. SPIE , vol.1137 , pp. 84-90
    • Fuderer, M.1
  • 31
    • 0002200424 scopus 로고
    • Statistical methods for tomographic image reconstruction
    • Geman S., McClure D.E. Statistical methods for tomographic image reconstruction. Bull. Int. Statist. Inst. 4:1987;5-21.
    • (1987) Bull. Int. Statist. Inst. , vol.4 , pp. 5-21
    • Geman, S.1    McClure, D.E.2
  • 32
    • 0000034281 scopus 로고
    • Image restoration using a Lorentzian probability model
    • Lettington A.H., Hong Q.H. Image restoration using a Lorentzian probability model. J. Modern Opt. 42:1995;1367-1376.
    • (1995) J. Modern Opt. , vol.42 , pp. 1367-1376
    • Lettington, A.H.1    Hong, Q.H.2
  • 33
    • 0030649677 scopus 로고    scopus 로고
    • On the use of Gibbs priors for Bayesian image restoration
    • Sebastiani G., Godtliebsen F. On the use of Gibbs priors for Bayesian image restoration. Signal Process. 56:1997;111-118.
    • (1997) Signal Process. , vol.56 , pp. 111-118
    • Sebastiani, G.1    Godtliebsen, F.2
  • 34
    • 0016068330 scopus 로고
    • The Fourier reconstruction of a head section
    • Shepp L.A., Logan B.F. The Fourier reconstruction of a head section. IEEE Trans. Nucl. Sci. 21:1974;21-43.
    • (1974) IEEE Trans. Nucl. Sci. , vol.21 , pp. 21-43
    • Shepp, L.A.1    Logan, B.F.2
  • 36
    • 0028839871 scopus 로고
    • The Rician distribution of noisy MRI data
    • Gudbjartsson H., Patz S. The Rician distribution of noisy MRI data. Magn. Reson. Med. 34:1995;910-914.
    • (1995) Magn. Reson. Med. , vol.34 , pp. 910-914
    • Gudbjartsson, H.1    Patz, S.2
  • 38
    • 0033006173 scopus 로고    scopus 로고
    • Rotation of NMR images using the 2D chirp-z transform
    • Tong R., Cox R.W. Rotation of NMR images using the 2D chirp-z transform. Magn. Reson. Med. 41:1999;253-256.
    • (1999) Magn. Reson. Med. , vol.41 , pp. 253-256
    • Tong, R.1    Cox, R.W.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.