Volumn 24, Issue 7, 2003, Pages 483-489

Efficacy of environmental measures in reducing potentially infectious bioaerosols during sputum induction

Author keywords

[No Author keywords available]

Indexed keywords

AEROSOL; AIR SAMPLING; AIRBORNE INFECTION; ARTICLE; COUGHING; EXHAUST GAS; ROOM VENTILATION; SPUTUM EXAMINATION; SPUTUM INDUCTION; TUBERCULOSIS; ULTRAVIOLET RADIATION; VENTILATOR;

EID: 0042490717     PISSN: 0899823X     EISSN: None     Source Type: Journal    
DOI: 10.1086/502242     Document Type: Article
Times cited : (15)

References (28)
  • 1
    • 0028781855 scopus 로고
    • Guidelines for preventing the transmission of Mycebacterium tuberculosis in health-care facilities
    • Centers for Disease Control and Prevention. Guidelines for preventing the transmission of Mycebacterium tuberculosis in health-care facilities. MMWR 1994;43(RR13):1-132.
    • (1994) MMWR , vol.43 , Issue.RR13 , pp. 1-132
  • 2
    • 45849154499 scopus 로고    scopus 로고
    • Guidelines for preventing the transmission of tuberculosis in Canadian health care facilities and other institutional settings
    • Health Canada. Guidelines for preventing the transmission of tuberculosis in Canadian health care facilities and other institutional settings. Can Commun Dis Rep 1996;22(suppl 1):1-50.
    • (1996) Can Commun Dis Rep , vol.22 , Issue.SUPPL. 1 , pp. 1-50
  • 3
    • 0028985773 scopus 로고
    • Control of nosocomial transmission of multidrug-resistant Mycobacterium tuberculosis among healthcare workers and HIV-infected patients
    • Wenger PN, Otten J, Breeden A, Orfas D, Beck-Sague CM, Jarvis WR. Control of nosocomial transmission of multidrug-resistant Mycobacterium tuberculosis among healthcare workers and HIV-infected patients. Lancet 1995;345:235-240.
    • (1995) Lancet , vol.345 , pp. 235-240
    • Wenger, P.N.1    Otten, J.2    Breeden, A.3    Orfas, D.4    Beck-Sague, C.M.5    Jarvis, W.R.6
  • 4
    • 0029618021 scopus 로고
    • Dramatic decrease in tuberculin skin test conversion rate among employees at a hospital in New York City
    • Fella P, Rivera P, Hale M, Squires K, Sepkowitz K. Dramatic decrease in tuberculin skin test conversion rate among employees at a hospital in New York City. Am J Infect Control 1995;23:352-356.
    • (1995) Am J Infect Control , vol.23 , pp. 352-356
    • Fella, P.1    Rivera, P.2    Hale, M.3    Squires, K.4    Sepkowitz, K.5
  • 5
    • 0028877715 scopus 로고
    • Efficacy of control measures in preventing nosocomial transmission of multidrug-resistant tuberculosis to patients and health care workers
    • Maloney SA, Pearson ML, Gordon MT, Del Castillo R, Boyle JF, Jarvis WR. Efficacy of control measures in preventing nosocomial transmission of multidrug-resistant tuberculosis to patients and health care workers. Ann Intern Med 1995;122:90-95.
    • (1995) Ann Intern Med , vol.122 , pp. 90-95
    • Maloney, S.A.1    Pearson, M.L.2    Gordon, M.T.3    Del Castillo, R.4    Boyle, J.F.5    Jarvis, W.R.6
  • 6
    • 0028920032 scopus 로고
    • Preventing the nosocomial transmission of tuberculosis
    • Blumberg HM, Watkins DL, Jeffrey PA-C, et al. Preventing the nosocomial transmission of tuberculosis. Ann Intern Med 1995;122:658-663.
    • (1995) Ann Intern Med , vol.122 , pp. 658-663
    • Blumberg, H.M.1    Watkins, D.L.2    Jeffrey, P.A.-C.3
  • 7
    • 0031201351 scopus 로고    scopus 로고
    • The cost of selected tuberculosis control measures at hospitals with a history of Mycobacterium tuberculosis outbreaks
    • Kellerman S, Tokars JI, Jarvis WR. The cost of selected tuberculosis control measures at hospitals with a history of Mycobacterium tuberculosis outbreaks. Infect Control Hosp Epidemiol 1997;18:542-547.
    • (1997) Infect Control Hosp Epidemiol , vol.18 , pp. 542-547
    • Kellerman, S.1    Tokars, J.I.2    Jarvis, W.R.3
  • 8
    • 0017253040 scopus 로고
    • Ultraviolet susceptibility of bcg and virulent tubercle bacilli
    • Riley RL, Knight M, Middlebrook G. Ultraviolet susceptibility of bcg and virulent tubercle bacilli. Am Rev Respir Dis 1976;113:413-418.
    • (1976) Am Rev Respir Dis , vol.113 , pp. 413-418
    • Riley, R.L.1    Knight, M.2    Middlebrook, G.3
  • 9
    • 0015023610 scopus 로고
    • Relative susceptibility of acid-fast and non-acid-fast bacteria to ultraviolet light
    • Collins FM. Relative susceptibility of acid-fast and non-acid-fast bacteria to ultraviolet light. Appl Microbiol 1971;21:411-413.
    • (1971) Appl Microbiol , vol.21 , pp. 411-413
    • Collins, F.M.1
  • 11
    • 0041489003 scopus 로고
    • The environmental control of epidemic contagion: An epidemiologic study of radiant disinfection of air in day schools
    • Wells WF, Wells MW, Wilder TS. The environmental control of epidemic contagion: an epidemiologic study of radiant disinfection of air in day schools. American Journal of Hygiene 1941;27:97-121.
    • (1941) American Journal of Hygiene , vol.27 , pp. 97-121
    • Wells, W.F.1    Wells, M.W.2    Wilder, T.S.3
  • 12
    • 0001126835 scopus 로고
    • Effect of ultraviolet irradiation of classrooms on spread of measles in large rural central schools
    • Perkins JE, Bahlke AM, Silverman HF. Effect of ultraviolet irradiation of classrooms on spread of measles in large rural central schools. Am J Public Health 1947;37:529-537.
    • (1947) Am J Public Health , vol.37 , pp. 529-537
    • Perkins, J.E.1    Bahlke, A.M.2    Silverman, H.F.3
  • 13
    • 0001750013 scopus 로고
    • Studies of the control of respiratory diseases among naval recruits: A review of a four-year experience with ultraviolet irradiation and dust suppressive measures, 1943-1947
    • Willmon TL, Hollaender A, Langmuir AD. Studies of the control of respiratory diseases among naval recruits: a review of a four-year experience with ultraviolet irradiation and dust suppressive measures, 1943-1947. American Journal of Hygiene 1948;48:227-232.
    • (1948) American Journal of Hygiene , vol.48 , pp. 227-232
    • Willmon, T.L.1    Hollaender, A.2    Langmuir, A.D.3
  • 14
    • 77957178387 scopus 로고
    • On air-borne infection: Study II. Droplets and droplet nuclei
    • Wells WF. On air-borne infection: Study II. Droplets and droplet nuclei. American Journal of Hygiene 1934;20:611-618.
    • (1934) American Journal of Hygiene , vol.20 , pp. 611-618
    • Wells, W.F.1
  • 15
    • 0028888668 scopus 로고
    • Tuberculosis among health care workers
    • Menzies RI, Fanning A, Yuan L. Tuberculosis among health care workers. N Engl J Med 1995;332:92-98.
    • (1995) N Engl J Med , vol.332 , pp. 92-98
    • Menzies, R.I.1    Fanning, A.2    Yuan, L.3
  • 16
    • 0029815502 scopus 로고    scopus 로고
    • The association between occupation and tuberculosis: A population-based survey
    • McKenna MT, Hutton M, Cauthen G, Onorato IM. The association between occupation and tuberculosis: a population-based survey. Am J Respir Crit Care Med 1996;154:587-593.
    • (1996) Am J Respir Crit Care Med , vol.154 , pp. 587-593
    • McKenna, M.T.1    Hutton, M.2    Cauthen, G.3    Onorato, I.M.4
  • 17
    • 0034700254 scopus 로고    scopus 로고
    • Hospital ventilation and risk of tuberculous infection in Canadian health care workers
    • Menzies RI, Fanning A, Yuan L, Fitzgerald JM. Hospital ventilation and risk of tuberculous infection in Canadian health care workers. Ann Intern Med 2000;133:779-789.
    • (2000) Ann Intern Med , vol.133 , pp. 779-789
    • Menzies, R.I.1    Fanning, A.2    Yuan, L.3    Fitzgerald, J.M.4
  • 19
    • 0029200731 scopus 로고
    • Comparison of sputum induction with fiberoptic bronchoscopy in the diagnosis of tuberculosis
    • Anderson C, Inhaber N, Menzies RI. Comparison of sputum induction with fiberoptic bronchoscopy in the diagnosis of tuberculosis. Am J Respir Crit Care Med 1995;152:1570-1574.
    • (1995) Am J Respir Crit Care Med , vol.152 , pp. 1570-1574
    • Anderson, C.1    Inhaber, N.2    Menzies, R.I.3
  • 20
    • 0028807471 scopus 로고
    • Measuring ventilation of patient care areas in hospitals: Description of a new protocol
    • Menzies RI, Schwartzman K, Loo V, Pasztor J. Measuring ventilation of patient care areas in hospitals: description of a new protocol. Am J Respir Crit Care Med 1995;152:1992-1999.
    • (1995) Am J Respir Crit Care Med , vol.152 , pp. 1992-1999
    • Menzies, R.I.1    Schwartzman, K.2    Loo, V.3    Pasztor, J.4
  • 23
    • 0032175014 scopus 로고    scopus 로고
    • The relative efficacy of respirators and room ventilation in preventing occupational tuberculosis
    • Fennelly KP, Nardell EA. The relative efficacy of respirators and room ventilation in preventing occupational tuberculosis. Infect Control Hosp Epidemiol 1998;19:754-759.
    • (1998) Infect Control Hosp Epidemiol , vol.19 , pp. 754-759
    • Fennelly, K.P.1    Nardell, E.A.2
  • 24
    • 0028899193 scopus 로고
    • Interrupting transmission from patients with unsuspected tuberculosis: A unique role for upper-room ultraviolet air disinfection
    • Nardell EA. Interrupting transmission from patients with unsuspected tuberculosis: a unique role for upper-room ultraviolet air disinfection. Am J Infect Control 1995;23:156-164.
    • (1995) Am J Infect Control , vol.23 , pp. 156-164
    • Nardell, E.A.1
  • 25
    • 0015011769 scopus 로고
    • Convention, air mixing and ultraviolet air disinfection in rooms
    • Riley RL, Permutt S, Kaufman JE. Convention, air mixing and ultraviolet air disinfection in rooms. Arch Environ Health 1971;22:200-207.
    • (1971) Arch Environ Health , vol.22 , pp. 200-207
    • Riley, R.L.1    Permutt, S.2    Kaufman, J.E.3
  • 26
    • 0032994592 scopus 로고    scopus 로고
    • A multi-zone model evaluation of the efficacy of upper-room air ultraviolet germicidal irradiation
    • Nicas M, Miller SL. A multi-zone model evaluation of the efficacy of upper-room air ultraviolet germicidal irradiation. Appl Occup Environ Hyg 1999;14:317-328.
    • (1999) Appl Occup Environ Hyg , vol.14 , pp. 317-328
    • Nicas, M.1    Miller, S.L.2
  • 28
    • 0015360098 scopus 로고
    • Effect of relative humidity on the inactivation of airborne Serratia marcescens by ultraviolet radiation
    • Riley RL, Kaufman JE. Effect of relative humidity on the inactivation of airborne Serratia marcescens by ultraviolet radiation. Appl Microbiol 1972;23:1113-1120.
    • (1972) Appl Microbiol , vol.23 , pp. 1113-1120
    • Riley, R.L.1    Kaufman, J.E.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.