메뉴 건너뛰기




Volumn 13, Issue 2 II, 2003, Pages 2294-2297

Optimization of 1 MVA high Tc superconducting transformer windings

Author keywords

Double pancake winding; HTS transformer; Perpendicular component of magnetic flux density (Br)

Indexed keywords

CRITICAL CURRENTS; ELECTRIC INSULATION; MAGNETIC FLUX; MAGNETIC PERMEABILITY; SUPERCONDUCTING TRANSITION TEMPERATURE; TRANSFORMER WINDINGS;

EID: 0042473220     PISSN: 10518223     EISSN: None     Source Type: Journal    
DOI: 10.1109/TASC.2003.813083     Document Type: Conference Paper
Times cited : (7)

References (7)
  • 2
    • 0032207746 scopus 로고    scopus 로고
    • 630 kVA high-temperature superconducting transformer
    • H. Zueger, "630 kVA high-temperature superconducting transformer," Cryogenics, vol. 38, pp. 1169-1172, 1998.
    • (1998) Cryogenics , vol.38 , pp. 1169-1172
    • Zueger, H.1
  • 3
    • 0032645952 scopus 로고    scopus 로고
    • Performance of a 1 MVA demonstration transformer
    • June
    • S. W. Schwenterly et al., "Performance of a 1 MVA demonstration transformer," IEEE Trans. Appl. Supercond., vol. 9, no. 2, pp. 680-684, June 1999.
    • (1999) IEEE Trans. Appl. Supercond. , vol.9 , Issue.2 , pp. 680-684
    • Schwenterly, S.W.1
  • 4
    • 17844411460 scopus 로고    scopus 로고
    • Development of a 22 kV/6.9 kV single-phase model for a 3 MVA HTS power transformer
    • March
    • K. Funaki et al., "Development of a 22 kV/6.9 kV single-phase model for a 3 MVA HTS power transformer," IEEE Trans. Appl. Supercond., vol. 11, no. 1, pp. 1578-1581, March 2001.
    • (2001) IEEE Trans. Appl. Supercond. , vol.11 , Issue.1 , pp. 1578-1581
    • Funaki, K.1
  • 5
    • 0035268542 scopus 로고    scopus 로고
    • An optimal design method for superconducting magnets using HTS tape
    • March
    • S. Noguchi, M. Yamashita, H. Yamashita, and A. Ishiyama, "An optimal design method for superconducting magnets using HTS tape," IEEE Trans. Appl. Supercond., vol. 11, no. 1, pp. 2308-2311, March 2001.
    • (2001) IEEE Trans. Appl. Supercond. , vol.11 , Issue.1 , pp. 2308-2311
    • Noguchi, S.1    Yamashita, M.2    Yamashita, H.3    Ishiyama, A.4
  • 7
    • 0035268395 scopus 로고    scopus 로고
    • The effect of flux diverters on AC losses of a 10 kVA high temperature superconducting demonstrator transformer
    • March
    • M. K. Al-Mosawi, C. Beduz, and Y. Yang, "The effect of flux diverters on AC losses of a 10 kVA high temperature superconducting demonstrator transformer," IEEE Trans. Appl. Supercond., vol. 11, no. 1, pp. 2800-2803, March 2001.
    • (2001) IEEE Trans. Appl. Supercond. , vol.11 , Issue.1 , pp. 2800-2803
    • Al-Mosawi, M.K.1    Beduz, C.2    Yang, Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.