메뉴 건너뛰기




Volumn 54, Issue 1, 2001, Pages 16-21

Transthoracic echocardiography study of the left anterior descending coronary artery with a high frequency transducer;Rendimiento de la ecocardiografía transtorácica con sonda de alta frecuencia en el estudio de la descendente anterior

Author keywords

Atherosclerosis; Coronary disease; Echocardiography

Indexed keywords

AGED; ARTICLE; CORONARY BLOOD VESSEL; ECHOGRAPHY; FEMALE; HEART INFARCTION; HUMAN; INSTRUMENTATION; MALE; MIDDLE AGED; TRANSESOPHAGEAL ECHOCARDIOGRAPHY;

EID: 0042463732     PISSN: 03008932     EISSN: None     Source Type: Journal    
DOI: 10.1016/s0300-8932(01)76259-8     Document Type: Article
Times cited : (3)

References (19)
  • 2
    • 0033081634 scopus 로고    scopus 로고
    • Coronary calcification by electron beam computed tomography and obstructive coronary artery disease: A model for costs and effectiveness of diagnosis as compared with conventional cardiac testing methods
    • Rumberger JA, Behrenbeck T, Breen JF, Sheedy PF. Coronary calcification by electron beam computed tomography and obstructive coronary artery disease: a model for costs and effectiveness of diagnosis as compared with conventional cardiac testing methods. J Am Coll Cardiol 1999; 33: 453-462.
    • (1999) J Am Coll Cardiol , vol.33 , pp. 453-462
    • Rumberger, J.A.1    Behrenbeck, T.2    Breen, J.F.3    Sheedy, P.F.4
  • 3
    • 0017188306 scopus 로고
    • Non invasive visualization of left main coronary artery by cross-sectional echocardiography
    • Weyman AE, Feigenbaum H, Dillon JC, Johnston KW, Eggleton RC. Non invasive visualization of left main coronary artery by cross-sectional echocardiography. Circulation 1976; 54: 169-174.
    • (1976) Circulation , vol.54 , pp. 169-174
    • Weyman, A.E.1    Feigenbaum, H.2    Dillon, J.C.3    Johnston, K.W.4    Eggleton, R.C.5
  • 5
    • 4243756992 scopus 로고    scopus 로고
    • Estudio de la arteria mamaria interna mediante ecocardiografía transtorácica con sonda de alta frecuencia
    • Vaticón C, Maya JL, Guzmán G, Ortega J, García-Lledó A, Rodríguez A et al. Estudio de la arteria mamaria interna mediante ecocardiografía transtorácica con sonda de alta frecuencia. Rev Esp Cardiol 1999; 52 (Supl 4): 113.
    • (1999) Rev Esp Cardiol , vol.52 , Issue.4 SUPL , pp. 113
    • Vaticón, C.1    Maya, J.L.2    Guzmán, G.3    Ortega, J.4    García-Lledó, A.5    Rodríguez, A.6
  • 6
    • 0033191448 scopus 로고    scopus 로고
    • Evaluación de la permeabilidad de los injertos de arteria mamaria interna izquierda mediante análisis de la velocidad del flujo por técniza doppler transcutánea
    • Sualís A, Carreras F, Borrás X, García-Picart J, Montiel J, Pons-Lladó G. Evaluación de la permeabilidad de los injertos de arteria mamaria interna izquierda mediante análisis de la velocidad del flujo por técniza Doppler transcutánea. Rev Esp Cardiol 1999; 52: 681-687.
    • (1999) Rev Esp Cardiol , vol.52 , pp. 681-687
    • Sualís, A.1    Carreras, F.2    Borrás, X.3    García-Picart, J.4    Montiel, J.5    Pons-Lladó, G.6
  • 7
    • 0032543625 scopus 로고    scopus 로고
    • Imaging of the distal left anterior descending coronary artery by transthoracic color-Doppler echocardiography
    • Voci P, Testa G, Plaustro G. Imaging of the distal left anterior descending coronary artery by transthoracic color-Doppler echocardiography. Am J Cardiol 1998; 81: 74G-78G.
    • (1998) Am J Cardiol , vol.81
    • Voci, P.1    Testa, G.2    Plaustro, G.3
  • 8
    • 0032962746 scopus 로고    scopus 로고
    • New non invasive method for coronary flow reserve assesment: Contrast-enhanced transthoracic second harmonic echo Doppler
    • Caiati C, Montaldo C, Zedda N, Bina A, Iliceto S. New non invasive method for coronary flow reserve assesment: contrast-enhanced transthoracic second harmonic echo Doppler. Circulation 1999; 99: 771-778.
    • (1999) Circulation , vol.99 , pp. 771-778
    • Caiati, C.1    Montaldo, C.2    Zedda, N.3    Bina, A.4    Iliceto, S.5
  • 9
    • 0031137260 scopus 로고    scopus 로고
    • Transthoracic echocardiographic measurement of coronary blood flow and reserve
    • Crowley JJ, Shapiro LM. Transthoracic echocardiographic measurement of coronary blood flow and reserve. J Am Soc Echocardiogr 1997; 10: 337-343.
    • (1997) J Am Soc Echocardiogr , vol.10 , pp. 337-343
    • Crowley, J.J.1    Shapiro, L.M.2
  • 10
    • 0032518844 scopus 로고    scopus 로고
    • Visualization of stents in the left anterior descending coronary artery by transthoracic echocardiograohy in pigs and humans
    • Birnbaum Y, Chaux A, Luo H, Nagai T, Naqvi T, Siegel RJ. Visualization of stents in the left anterior descending coronary artery by transthoracic echocardiograohy in pigs and humans. Am J Cardiol 1998; 81: 229-230.
    • (1998) Am J Cardiol , vol.81 , pp. 229-230
    • Birnbaum, Y.1    Chaux, A.2    Luo, H.3    Nagai, T.4    Naqvi, T.5    Siegel, R.J.6
  • 11
    • 0030963677 scopus 로고    scopus 로고
    • Analysis of phasic flow velocity dynamics in the left anterior descending coronary artery before and after angioplasty using transthoracic echocardiography in patients with stable angina pectoris
    • Crowley JJ, Shapiro LM. Analysis of phasic flow velocity dynamics in the left anterior descending coronary artery before and after angioplasty using transthoracic echocardiography in patients with stable angina pectoris. Am J Cardiol 1997; 80: 615-616.
    • (1997) Am J Cardiol , vol.80 , pp. 615-616
    • Crowley, J.J.1    Shapiro, L.M.2
  • 12
    • 0031943638 scopus 로고    scopus 로고
    • Noninvasive analysis of coronary artery poststenotic flow characteristics by using transthoracic echocardiography
    • Crowley JJ, Shapiro LM. Noninvasive analysis of coronary artery poststenotic flow characteristics by using transthoracic echocardiography. J Am Soc Echocardiogr 1998; 11: 1-9.
    • (1998) J Am Soc Echocardiogr , vol.11 , pp. 1-9
    • Crowley, J.J.1    Shapiro, L.M.2
  • 13
    • 0032803132 scopus 로고    scopus 로고
    • Potential use of transthoracic echocardiography in the assessment of coronary flow reserve
    • David JR, Shapiro LM. Potential use of transthoracic echocardiography in the assessment of coronary flow reserve. J Am Soc Echocardiogr 1999; 12: 590-595.
    • (1999) J Am Soc Echocardiogr , vol.12 , pp. 590-595
    • David, J.R.1    Shapiro, L.M.2
  • 14
    • 0025093468 scopus 로고
    • Transthoracic two-dimensional high frequency (7.5 MHz) ultrasonic visualization of the distal left anterior descending coronary artery
    • Ross JJ, Mintz GS. Transthoracic two-dimensional high frequency (7.5 MHz) ultrasonic visualization of the distal left anterior descending coronary artery. J Am Coll Cardiol 1990; 15: 373-377.
    • (1990) J Am Coll Cardiol , vol.15 , pp. 373-377
    • Ross, J.J.1    Mintz, G.S.2
  • 15
    • 0033005136 scopus 로고    scopus 로고
    • Improved high-frequency transthoracic flow velocity measurement in the left anterior descending coronary artery after intravenous peripheral injection of levovist
    • Bartel T, Müller S, Baumgart D, Mathew T, Haude M, Erbel R. Improved high-frequency transthoracic flow velocity measurement in the left anterior descending coronary artery after intravenous peripheral injection of levovist. J Am Soc Echocardiogr 1999; 12: 252-256.
    • (1999) J Am Soc Echocardiogr , vol.12 , pp. 252-256
    • Bartel, T.1    Müller, S.2    Baumgart, D.3    Mathew, T.4    Haude, M.5    Erbel, R.6
  • 16
    • 0033058825 scopus 로고    scopus 로고
    • Non-invasive assessment of coronary flow reserve with transthoracic signal-enhanced Doppler echocardiography
    • Lambertz H, Tries HP, Stein T, Lethen H. Non-invasive assessment of coronary flow reserve with transthoracic signal-enhanced Doppler echocardiography. J Am Soc Echocardiogr 1999; 12: 186-195.
    • (1999) J Am Soc Echocardiogr , vol.12 , pp. 186-195
    • Lambertz, H.1    Tries, H.P.2    Stein, T.3    Lethen, H.4
  • 17
    • 0027300388 scopus 로고
    • Coronary flow velocity dynamics in normal and diseased arteries
    • Ofili EO, Labovitz AJ, Kern MJ. Coronary flow velocity dynamics in normal and diseased arteries. J Am Coll Cardiol 1993; 71: 3D-9D.
    • (1993) J Am Coll Cardiol , vol.71
    • Ofili, E.O.1    Labovitz, A.J.2    Kern, M.J.3
  • 18
    • 0027299032 scopus 로고
    • Applications of coronary flow velocity during angioplasty and other coronary interventional procedures
    • Segal J. Applications of coronary flow velocity during angioplasty and other coronary interventional procedures. Am J Cardiol 1993; 71: 17D-25D.
    • (1993) Am J Cardiol , vol.71
    • Segal, J.1
  • 19
    • 0016522772 scopus 로고
    • On the fluid mechanics of human coronary artery stenosis
    • Logan SE. On the fluid mechanics of human coronary artery stenosis. IEEE Trans Biomed Eng 1975; 22: 327-334.
    • (1975) IEEE Trans Biomed Eng , vol.22 , pp. 327-334
    • Logan, S.E.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.