메뉴 건너뛰기




Volumn 13, Issue 2 I, 2003, Pages 755-758

A multichannel SQUID magnetometer system based on double relaxation oscillation SQUIDs

Author keywords

Double relaxation oscillation SQUID; Flux locked loop; Magnetoencephalogram; SQUID magnetometer

Indexed keywords

ELECTRIC INDUCTORS; MAGNETIC COUPLINGS; MAGNETIC HYSTERESIS; MAGNETOMETERS; OSCILLATIONS; RESISTORS;

EID: 0042442021     PISSN: 10518223     EISSN: None     Source Type: Journal    
DOI: 10.1109/TASC.2003.814031     Document Type: Conference Paper
Times cited : (2)

References (8)
  • 1
    • 0002729192 scopus 로고    scopus 로고
    • Advanced SQUID readout electronics
    • H. Weinstock, Ed. Dordrecht: Kluwer Academic Publishers
    • D. Drang, "Advanced SQUID readout electronics," in SQUID Sensors: Fundamentals, Fabrication and Application, H. Weinstock, Ed. Dordrecht: Kluwer Academic Publishers, 1996, pp. 63-116.
    • (1996) SQUID Sensors: Fundamentals, Fabrication and Application, , pp. 63-116
    • Drang, D.1
  • 2
    • 0001388969 scopus 로고
    • (Double) relaxation oscillation SQUIDs with high flux-to-voltage transfer: Simulations and experiments
    • D. J. Adelerhof, H. Nijstad, F. Flokstra, and H. Rogalla, "(Double) relaxation oscillation SQUIDs with high flux-to-voltage transfer: Simulations and experiments," J. Appl. Phys., vol. 76, pp. 3875-3886, 1994.
    • (1994) J. Appl. Phys. , vol.76 , pp. 3875-3886
    • Adelerhof, D.J.1    Nijstad, H.2    Flokstra, F.3    Rogalla, H.4
  • 3
    • 0031175149 scopus 로고    scopus 로고
    • Double relaxation oscillation SQUID with reference junction for biomagnetic multichannel applications
    • Y. H. Lee, H. C. Kwon, J. M. Kim, Y. K. Park, and J. C. Park, "Double relaxation oscillation SQUID with reference junction for biomagnetic multichannel applications," Appl. Supercond.,vol. 5, pp. 413-418, 1998.
    • (1998) Appl. Supercond. , vol.5 , pp. 413-418
    • Lee, Y.H.1    Kwon, H.C.2    Kim, J.M.3    Park, Y.K.4    Park, J.C.5
  • 4
    • 0004890888 scopus 로고
    • High sensitivity double relaxation oscillation superconducting quantum interference devices with large transfer from flux to voltage
    • D. J. Adelerhof, J. Kawai, G. Uehara, and H. Kado, "High sensitivity double relaxation oscillation superconducting quantum interference devices with large transfer from flux to voltage," Rev. Sci. Instrum., vol. 66, pp. 2631-2637, 1995.
    • (1995) Rev. Sci. Instrum. , vol.66 , pp. 2631-2637
    • Adelerhof, D.J.1    Kawai, J.2    Uehara, G.3    Kado, H.4
  • 5
    • 0023398943 scopus 로고
    • Effects of DC SQUID characteristics of damping of input coil resonances
    • J. Knuutila, A. Ahonen, and C. Tesche, "Effects of DC SQUID characteristics of damping of input coil resonances," J. Low Temp. Phys., vol. 68, pp. 269-284, 1987.
    • (1987) J. Low Temp. Phys. , vol.68 , pp. 269-284
    • Knuutila, J.1    Ahonen, A.2    Tesche, C.3
  • 6
    • 0007588066 scopus 로고    scopus 로고
    • Construction and characteristics of a magnetically shielded room for biomagnetic measurements
    • Y. H. Lee, H. C. Kwon, J. M. Kim, C. M. Lim, S. K. Lee, Y. K. Park, and J. C. Park, "Construction and characteristics of a magnetically shielded room for biomagnetic measurements," J. Kor. Magn. Soc., vol. 6, pp. 264-270, 1996.
    • (1996) J. Kor. Magn. Soc. , vol.6 , pp. 264-270
    • Lee, Y.H.1    Kwon, H.C.2    Kim, J.M.3    Lim, C.M.4    Lee, S.K.5    Park, Y.K.6    Park, J.C.7
  • 7
    • 0007548695 scopus 로고    scopus 로고
    • Noise characteristics of double relaxation oscillation superconducting quantum interference devices with reference junction
    • Y. H. Lee, H. C. Kwon, J. M. Kim, Y. K. Park, and J. C. Park, "Noise characteristics of double relaxation oscillation superconducting quantum interference devices with reference junction," Supercond. Sci. Technol., vol. 5, pp. 413-418, 1998.
    • (1998) Supercond. Sci. Technol. , vol.5 , pp. 413-418
    • Lee, Y.H.1    Kwon, H.C.2    Kim, J.M.3    Park, Y.K.4    Park, J.C.5
  • 8
    • 0032808535 scopus 로고    scopus 로고
    • Principal component elimination method for the improvement of S/N in evoked neuromagnetic field measurements
    • T. Kobayashi and S. Kuriki, "Principal component elimination method for the improvement of S/N in evoked neuromagnetic field measurements," IEEE Trans. Biomed. Eng., vol. 46, pp. 951-958, 1999.
    • (1999) IEEE Trans. Biomed. Eng. , vol.46 , pp. 951-958
    • Kobayashi, T.1    Kuriki, S.2