메뉴 건너뛰기




Volumn 3149, Issue , 1997, Pages 203-212

Spiral CT: Current status and future directions

Author keywords

Cone beam; Fan beam; Iterative reconstruction; Spiral helical scanning; X ray computed tomography (CT); X ray micro CT

Indexed keywords

COMPUTERIZED TOMOGRAPHY; DIAGNOSTIC RADIOGRAPHY; ELECTRIC INSTRUMENT TRANSFORMERS; IMAGE RECONSTRUCTION; IMAGING SYSTEMS; PROGRAMMING THEORY; REPAIR; RESTORATION; SCANNING; SOLUTE TRANSPORT; TOMOGRAPHY; X RAYS;

EID: 0042436870     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.279358     Document Type: Conference Paper
Times cited : (9)

References (42)
  • 1
    • 0004033056 scopus 로고
    • Computerized tomographic apparatus utilizing a radiation source
    • U. S. Patent Number 4,630,202
    • I. Mori, "Computerized tomographic apparatus utilizing a radiation source." U. S. Patent Number 4,630,202, 1986.
    • (1986)
    • Mori, I.1
  • 2
    • 0025351273 scopus 로고
    • Spiral volumetric CT with single-breath-hold technique, continuous transport, and continuous scanner rotation
    • W. A. Kalender, W. Seissler, E. Klotz, and P. Vock, "Spiral volumetric CT with single-breath-hold technique, continuous transport, and continuous scanner rotation," Radiology 176, pp. 181-183, 1990.
    • (1990) Radiology , vol.176 , pp. 181-183
    • Kalender, W.A.1    Seissler, W.2    Klotz, E.3    Vock, P.4
  • 3
    • 0024945045 scopus 로고
    • Optimal interpolation in helical scan computed tomography
    • Glasgow, Scotland
    • Y. Bresler and C. J. Skrabacz, "Optimal interpolation in helical scan computed tomography," in Proc. ICASSP, vol. 3, pp. 1472-1475, (Glasgow, Scotland), 1989.
    • (1989) Proc. ICASSP , vol.3 , pp. 1472-1475
    • Bresler, Y.1    Skrabacz, C.J.2
  • 4
    • 0025221610 scopus 로고
    • Computed tomography scanning with simultaneous patient translation
    • C. R. Crawford and K. F. King, "Computed tomography scanning with simultaneous patient translation," Med. Phys. 17, pp. 967-982, 1990.
    • (1990) Med. Phys , vol.17 , pp. 967-982
    • Crawford, C.R.1    King, K.F.2
  • 5
    • 0026712389 scopus 로고
    • Evaluation of section sensitivity profiles and image noise in spiral CT
    • A. Polacin, W. A. Kalender, and G. Marchal, "Evaluation of section sensitivity profiles and image noise in spiral CT," Radiology 185, pp. 29-35, 1992.
    • (1992) Radiology , vol.185 , pp. 29-35
    • Polacin, A.1    Kalender, W.A.2    Marchal, G.3
  • 6
    • 0028258284 scopus 로고
    • Longitudinal resolution in volumetric x-ray CT - Analytical comparison between conventional and helical CT
    • G. Wang and M. W. Vannier, "Longitudinal resolution in volumetric x-ray CT - Analytical comparison between conventional and helical CT," Med. Phys. 21, pp. 429-433, 1994.
    • (1994) Med. Phys , vol.21 , pp. 429-433
    • Wang, G.1    Vannier, M.W.2
  • 7
    • 0028264008 scopus 로고
    • Theoretical FWTM values in helical CT
    • G. Wang, J. A. Brink, and M. W. Vannier, "Theoretical FWTM values in helical CT," Med. Phys. 21, pp. 753-754, 1994.
    • (1994) Med. Phys , vol.21 , pp. 753-754
    • Wang, G.1    Brink, J.A.2    Vannier, M.W.3
  • 8
    • 0028049871 scopus 로고
    • Spatial variation of section sensitivity profile in helical CT
    • G. Wang and M. W. Vannier, "Spatial variation of section sensitivity profile in helical CT," Med. Phys. 21, pp. 1491-1497, 1994.
    • (1994) Med. Phys , vol.21 , pp. 1491-1497
    • Wang, G.1    Vannier, M.W.2
  • 9
    • 0028298099 scopus 로고
    • A comparison of conventional and spiral CT: An experimental study on detection of spherical lesions
    • W. A. Kalender, A. Polacin, and C. Süss, "A comparison of conventional and spiral CT: An experimental study on detection of spherical lesions," J. of Computer Assisted Tomography 18, pp. 167-176, 1994.
    • (1994) J. of Computer Assisted Tomography , vol.18 , pp. 167-176
    • Kalender, W.A.1    Polacin, A.2    Süss, C.3
  • 10
    • 0029612812 scopus 로고
    • Thin-section three-dimensional spiral CT: Is isotropic imaging possible?
    • W. A. Kalender, "Thin-section three-dimensional spiral CT: Is isotropic imaging possible?," Radiology 197, pp. 578-580, 1995.
    • (1995) Radiology , vol.197 , pp. 578-580
    • Kalender, W.A.1
  • 11
    • 0027144470 scopus 로고
    • Helical CT image noise - Analytical results
    • G. Wang and M. W. Vannier, "Helical CT image noise - Analytical results," Med. Phys. 20, pp. 1635-1640, 1993.
    • (1993) Med. Phys , vol.20 , pp. 1635-1640
    • Wang, G.1    Vannier, M.W.2
  • 12
    • 0030901486 scopus 로고    scopus 로고
    • Low-contrast resolution in volumetric x-ray CT - Analytical comparison between conventional and spiral CT
    • in press
    • G. Wang and M. W. Vannier, "Low-contrast resolution in volumetric x-ray CT - Analytical comparison between conventional and spiral CT," Med. Phys. , 1997. in press.
    • (1997) Med. Phys
    • Wang, G.1    Vannier, M.W.2
  • 13
    • 0029393719 scopus 로고
    • Increased scan pitch for vascular and thoracic spiral CT
    • G. D. Rubin and S. Napel, "Increased scan pitch for vascular and thoracic spiral CT," Radiology 197, pp. 316-317, 1995.
    • (1995) Radiology , vol.197 , pp. 316-317
    • Rubin, G.D.1    Napel, S.2
  • 14
    • 0030137797 scopus 로고    scopus 로고
    • Maximum volume coverage in spiral CT
    • G. Wang and M. W. Vannier, "Maximum volume coverage in spiral CT," Academic Radiology 3, pp. 423-428, 1996.
    • (1996) Academic Radiology , vol.3 , pp. 423-428
    • Wang, G.1    Vannier, M.W.2
  • 15
    • 0010321031 scopus 로고    scopus 로고
    • Optimal pitch in spiral CT
    • to appear
    • G. Wang and M. W. Vannier, "Optimal pitch in spiral CT," Med. Phys. , 1997. to appear.
    • (1997) Med. Phys
    • Wang, G.1    Vannier, M.W.2
  • 16
    • 0028230441 scopus 로고
    • Stair-step artifacts in three-dimensional helical CT - An experimental study
    • G. Wang and M. W. Vannier, "Stair-step artifacts in three-dimensional helical CT - An experimental study," Radiology 191, pp. 79-83, 1994.
    • (1994) Radiology , vol.191 , pp. 79-83
    • Wang, G.1    Vannier, M.W.2
  • 17
    • 0029380602 scopus 로고
    • Temporal bone volumetric image deblurring in spiral CT
    • G. Wang, M. W. Skinner, and M. W. Vannier, "Temporal bone volumetric image deblurring in spiral CT," Academic Radiology 2, pp. 888-895, 1995.
    • (1995) Academic Radiology , vol.2 , pp. 888-895
    • Wang, G.1    Skinner, M.W.2    Vannier, M.W.3
  • 19
    • 0020703127 scopus 로고
    • Results of a comparative study of a reconstruction procedure for producing improved estimates of radioactivity distributions in time-of-flight emission tomography
    • D. G. Politte and D. L. Snyder, "Results of a comparative study of a reconstruction procedure for producing improved estimates of radioactivity distributions in time-of-flight emission tomography," IEEE Trans. Nucl. Sci. 31, pp. 614-619, 1984.
    • (1984) IEEE Trans. Nucl. Sci , vol.31 , pp. 614-619
    • Politte, D.G.1    Snyder, D.L.2
  • 20
    • 0001195059 scopus 로고
    • On a problem of I. M. Gel'fand
    • English translation
    • A. A. Kirillov, "On a problem of I. M. Gel'fand," Sov. Math. Dokl. 2, pp. 268-269, 1961. English translation.
    • (1961) Sov. Math. Dokl , vol.2 , pp. 268-269
    • Kirillov, A.A.1
  • 21
    • 0020764170 scopus 로고
    • An inversion formula for cone-beam reconstruction
    • H. K. Tuy, "An inversion formula for cone-beam reconstruction," SIAM J. Appl. Math. 43, pp. 546-552, 1983.
    • (1983) SIAM J. Appl. Math , vol.43 , pp. 546-552
    • Tuy, H.K.1
  • 22
    • 0022026907 scopus 로고
    • Image reconstruction from cone-beam projections: Necessary and sufficient conditions and reconstruction methods
    • B. D. Smith, "Image reconstruction from cone-beam projections: necessary and sufficient conditions and reconstruction methods," IEEE Trans. Med. Imag. MI-4, pp. 14-28, 1985.
    • (1985) IEEE Trans. Med. Imag , vol.MI-4 , pp. 14-28
    • Smith, B.D.1
  • 23
    • 0002018761 scopus 로고
    • Mathematical framework of cone beam 3d reconstruction via the first derivative of the radon transform
    • G. T. Herman, A. K. Louis, and F. Natterer, eds, Springer Verlag
    • P. Grangeat, "Mathematical framework of cone beam 3d reconstruction via the first derivative of the radon transform," in Mathematical Methods in Tomography, G. T. Herman, A. K. Louis, and F. Natterer, eds., Springer Verlag, 1990.
    • (1990) Mathematical Methods in Tomography
    • Grangeat, P.1
  • 24
    • 0026873904 scopus 로고
    • Implementation, investigation, and improvement of a novel cone-beam reconstruction method
    • B. D. Smith and J. X. Chen, "Implementation, investigation, and improvement of a novel cone-beam reconstruction method," IEEE Trans. Med. Imag. MI-11, pp. 260-266, 1992.
    • (1992) IEEE Trans. Med. Imag , vol.MI-11 , pp. 260-266
    • Smith, B.D.1    Chen, J.X.2
  • 25
    • 0027647186 scopus 로고
    • A reconstruction algorithm for helical cone-beam SPECT
    • Y. Weng, G. L. Zeng, and G. T. Gullberg, "A reconstruction algorithm for helical cone-beam SPECT," IEEE Trans. Nucl. Sci. 40, pp. 1092-1101, 1993.
    • (1993) IEEE Trans. Nucl. Sci , vol.40 , pp. 1092-1101
    • Weng, Y.1    Zeng, G.L.2    Gullberg, G.T.3
  • 26
    • 0026552271 scopus 로고
    • A cone-beam tomography algorithm for orthogonal circle-and-line orbit
    • G. L. Zheng and G. T. Gullberg, "A cone-beam tomography algorithm for orthogonal circle-and-line orbit," Phys. Med. Biol. 37, pp. 563-577, 1992.
    • (1992) Phys. Med. Biol , vol.37 , pp. 563-577
    • Zheng, G.L.1    Gullberg, G.T.2
  • 27
    • 0028392621 scopus 로고
    • A cone-beam reconstruction algorithm using shift-variant filtering and cone-beam backprojection
    • M. Defrise and R. Clack, "A cone-beam reconstruction algorithm using shift-variant filtering and cone-beam backprojection," IEEE Trans. Med. Imag. 13, pp. 186-195, 1994.
    • (1994) IEEE Trans. Med. Imag , vol.13 , pp. 186-195
    • Defrise, M.1    Clack, R.2
  • 28
    • 0028397603 scopus 로고
    • Derivation and implementation of a cone-beam reconstruction algorithm for nonplanar orbits
    • H. Kudo and T. Saito, "Derivation and implementation of a cone-beam reconstruction algorithm for nonplanar orbits," IEEE Trans. Med. Imag. 13, pp. 196-211, 1994.
    • (1994) IEEE Trans. Med. Imag , vol.13 , pp. 196-211
    • Kudo, H.1    Saito, T.2
  • 30
    • 0001211585 scopus 로고    scopus 로고
    • An improved cone-beam reconstruction algorithm for the circular orbit
    • H. Hu, "An improved cone-beam reconstruction algorithm for the circular orbit," J. Scanning Microscopy 18, pp. 572-581, 1996.
    • (1996) J. Scanning Microscopy , vol.18 , pp. 572-581
    • Hu, H.1
  • 31
    • 0028300221 scopus 로고
    • Implementation of Tuy's cone-beam inversion formula
    • G. L. Zeng, R. Clack, and G. T. Gullberg, "Implementation of Tuy's cone-beam inversion formula," Phys. Med. Biol. 39, pp. 493-507, 1994.
    • (1994) Phys. Med. Biol , vol.39 , pp. 493-507
    • Zeng, G.L.1    Clack, R.2    Gullberg, G.T.3
  • 33
    • 0027680702 scopus 로고
    • A derivative-free noncircular fan-beam reconstruction formula
    • G. Wang, T. H. Lin, and P. C. Cheng, "A derivative-free noncircular fan-beam reconstruction formula," IEEE Trans. on Image Processing 2, pp. 543-547, 1993.
    • (1993) IEEE Trans. on Image Processing , vol.2 , pp. 543-547
    • Wang, G.1    Lin, T.H.2    Cheng, P.C.3
  • 35
    • 0004464520 scopus 로고    scopus 로고
    • Exact and approximate cone-beam X-ray microtomography
    • Cheng et al, ed, World Scientific, Singapore, in press
    • G. Wang, S. Y. Zhao, and P. C. Cheng, "Exact and approximate cone-beam X-ray microtomography," in Modern Microscopies, Cheng et al, ed., vol. I, World Scientific, Singapore, 1997. in press.
    • (1997) Modern Microscopies , vol.1
    • Wang, G.1    Zhao, S.Y.2    Cheng, P.C.3
  • 37
    • 0021327145 scopus 로고
    • EM reconstruction algorithms for emission and transmission tomography
    • K. Lange and R. Carson, "EM reconstruction algorithms for emission and transmission tomography," J. Comput. Assisted Tomography 8, pp. 306-316, 1984.
    • (1984) J. Comput. Assisted Tomography , vol.8 , pp. 306-316
    • Lange, K.1    Carson, R.2
  • 39
    • 0025595687 scopus 로고
    • Why least squares and maximum entropy? An axiomatic approach to inference for linear inverse problems
    • I. Csiszàr, "Why least squares and maximum entropy? An axiomatic approach to inference for linear inverse problems," The Annals of Statistics 19, pp. 2032-2066, 1991.
    • (1991) The Annals of Statistics , vol.19 , pp. 2032-2066
    • Csiszàr, I.1
  • 40
    • 0025209334 scopus 로고
    • General entropy criteria for inverse problems, with applications to data compression, pattern classification and cluster analysis
    • L. K. Jones and C. L. Byrne, "General entropy criteria for inverse problems, with applications to data compression, pattern classification and cluster analysis," IEEE Trans. on Information Theory 36, pp. 23-30, 1990.
    • (1990) IEEE Trans. on Information Theory , vol.36 , pp. 23-30
    • Jones, L.K.1    Byrne, C.L.2
  • 42
    • 58749092827 scopus 로고    scopus 로고
    • An iterative algorithm for cone-beam tomography
    • in review
    • G. Wang, M. W. Vannier, and P. C. Cheng, "An iterative algorithm for cone-beam tomography," 1997. in review.
    • (1997)
    • Wang, G.1    Vannier, M.W.2    Cheng, P.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.