Volumn 5032 I, Issue , 2003, Pages 38-49

Automated classification of wall motion abnormalities by Principal Component Analysis of endocardial shape motion patterns in echocardiograms

Author keywords

Active Appearance Models; Cardiac; Classification; Computer Aided Diagnosis; Deformable models; Principal Component Analysis; Shape analysis; Time sequences; Ultrasound

Indexed keywords

ENDOCRINOLOGY; PATTERN RECOGNITION; PRINCIPAL COMPONENT ANALYSIS; REGRESSION ANALYSIS;

EID: 0042376129     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.481135     Document Type: Conference Paper
Times cited : (3)

References (22)
  • 2
    • 0030060589 scopus 로고    scopus 로고
    • Analysis of interinstitutional observer agreement in interpretation of dobutamine stress echocardiograms
    • R. Hoffman, H. Lethen, Th. H. Marwick et al., "Analysis of interinstitutional observer agreement in interpretation of dobutamine stress echocardiograms", J. Am. Coll. Cardiol. 27, pp. 330-336,1996.
    • (1996) J. Am. Coll. Cardiol. , vol.27 , pp. 330-336
    • Hoffman, R.1    Lethen, H.2    Marwick, Th.H.3
  • 3
    • 0027215024 scopus 로고
    • Comparison of models for quantitative left ventricular wall motion analysis from two-dimensional echocardiograms during acute myocardial infarction
    • P. A. Assman, C. J. Slager et al., "Comparison of models for quantitative left ventricular wall motion analysis from two-dimensional echocardiograms during acute myocardial infarction", Am. J. Cardiol. 71, pp. 1262-1269,1993.
    • (1993) Am. J. Cardiol. , vol.71 , pp. 1262-1269
    • Assman, P.A.1    Slager, C.J.2
  • 4
    • 4243619425 scopus 로고    scopus 로고
    • Automated echocardiographic confirmation of regional wall motion abnormalities: Quantitation of continuous LV volume
    • abstract
    • S. J. Fry, P. Hunziker, H. Bosch et al., "Automated echocardiographic confirmation of regional wall motion abnormalities: quantitation of continuous LV volume", abstract, J. Am. Coll. Cardiol. 31 (suppl. A) p. 56A, 1998.
    • (1998) J. Am. Coll. Cardiol. , vol.31 , Issue.SUPPL. A
    • Fry, S.J.1    Hunziker, P.2    Bosch, H.3
  • 5
    • 4243753809 scopus 로고    scopus 로고
    • Objective and quantitative stress echo analysis to diagnose coronary disease using model-based image processing
    • abstract
    • P. Hunziker, D. Yuan, L. Schöb et al., "Objective and quantitative stress echo analysis to diagnose coronary disease using model-based image processing", abstract, J. Am. Coll. Cardiol. 35 (Suppl A) p. 431 A, 2000.
    • (2000) J. Am. Coll. Cardiol. , vol.35 , Issue.SUPPL A
    • Hunziker, P.1    Yuan, D.2    Schöb, L.3
  • 6
    • 0036694790 scopus 로고    scopus 로고
    • Development of a fully quantitative approach to the interpretation of stress echocardiography using radial and longitudinal myocardial velocities
    • P. Cain, L. Short, T. Baglin et al, "Development of a fully quantitative approach to the interpretation of stress echocardiography using radial and longitudinal myocardial velocities", J. Am. Soc. Echocardiogr. 15, pp.759-767, 2002.
    • (2002) J. Am. Soc. Echocardiogr. , vol.15 , pp. 759-767
    • Cain, P.1    Short, L.2    Baglin, T.3
  • 7
    • 0029400775 scopus 로고
    • Evaluation of a semiautomatic contour detection approach in sequences of short-axis two-dimensional echocardiographic images
    • J. G. Bosch, L. H. Savalle et al., "Evaluation of a semiautomatic contour detection approach in sequences of short-axis two-dimensional echocardiographic images", J. Am. Soc. Echocardiogr. 8, pp. 810-821,1995.
    • (1995) J. Am. Soc. Echocardiogr. , vol.8 , pp. 810-821
    • Bosch, J.G.1    Savalle, L.H.2
  • 8
    • 0001930850 scopus 로고    scopus 로고
    • Overview of automated quantitation techniques in 2D echocardiography
    • J. Reiber and E. v.d. Wall, eds., Kluwer, Dordrecht
    • J. G. Bosch, G. van Burken et al, "Overview of automated quantitation techniques in 2D echocardiography", in What's new in cardiovascular imaging, J. Reiber and E. v.d. Wall, eds., pp. 363-376, Kluwer, Dordrecht, 1998.
    • (1998) What's New in Cardiovascular Imaging , pp. 363-376
    • Bosch, J.G.1    Van Burken, G.2
  • 9
    • 84957810778 scopus 로고    scopus 로고
    • Active appearance models
    • H. Burkhardt and B. Neumann, eds., Springer, Berlin
    • T. F. Cootes, G. J. Edwards and C. J. Taylor, "Active Appearance Models.", in European Conf. Computer Vision, H. Burkhardt and B. Neumann, eds., pp. 484-498, Springer, Berlin, 1998.
    • (1998) European Conf. Computer Vision , pp. 484-498
    • Cootes, T.F.1    Edwards, G.J.2    Taylor, C.J.3
  • 10
    • 0034849012 scopus 로고    scopus 로고
    • Statistical models of appearance for medical image analysis and computer vision
    • in Medical Imaging 2001: Image Processing, M. Sonka, K. M. Hanson, eds.
    • T. F. Cootes, C. J. Taylor, "Statistical models of appearance for medical image analysis and computer vision", in Medical Imaging 2001: Image Processing, M. Sonka, K. M. Hanson, eds., Proc. SPIE 4322, pp. 236-248, 2001.
    • (2001) Proc. SPIE , vol.4322 , pp. 236-248
    • Cootes, T.F.1    Taylor, C.J.2
  • 11
    • 0028463039 scopus 로고
    • Use of active shape models for locating structures in medical images
    • T. F. Cootes, A. Hill, C. J. Taylor and J. Haslam, "Use of active shape models for locating structures in medical images", Image and Vision Computing 12, pp. 355-366, 1994.
    • (1994) Image and Vision Computing , vol.12 , pp. 355-366
    • Cootes, T.F.1    Hill, A.2    Taylor, C.J.3    Haslam, J.4
  • 12
    • 0034847221 scopus 로고    scopus 로고
    • Active Appearance Motion Models for endocardial contour detection in time sequences of echocardiograms
    • in Medical Imaging 2001: Image Processing, M. Sonka, K. M. Hanson, eds.
    • H. G. Bosch, S. C. Mitchell, B. P. F. Lelieveldt et al., "Active Appearance Motion Models for endocardial contour detection in time sequences of echocardiograms", in Medical Imaging 2001: Image Processing, M. Sonka, K. M. Hanson, eds., Proc. SPIE 4322, pp. 257-268, 2001.
    • (2001) Proc. SPIE , vol.4322 , pp. 257-268
    • Bosch, H.G.1    Mitchell, S.C.2    Lelieveldt, B.P.F.3
  • 13
    • 0036879771 scopus 로고    scopus 로고
    • Automatic segmentation of echocardiographic sequences by active appearance motion models
    • J. G. Bosch, S. C. Mitchell, B. P. F. Lelieveldt et al., "Automatic segmentation of echocardiographic sequences by Active Appearance Motion Models" IEEE Trans. Med. Imaging 21, pp. 1374-1383, 2002.
    • (2002) IEEE Trans. Med. Imaging , vol.21 , pp. 1374-1383
    • Bosch, J.G.1    Mitchell, S.C.2    Lelieveldt, B.P.F.3
  • 14
    • 0036034087 scopus 로고    scopus 로고
    • Fully automated endocardial contour detection in time sequences of echocardiograms by three-dimensional active appearance models
    • in Medical Imaging 2002: Image Processing, M. Sonka, J. M. Fitzpatrick, eds.
    • J. G. Bosch, S. C. Mitchell, B. P. F. Lelieveldt, et al., "Fully automated endocardial contour detection in time sequences of echocardiograms by three-dimensional Active Appearance Models", in Medical Imaging 2002: Image Processing, M. Sonka, J. M. Fitzpatrick, eds., Proc. SPIE 4684, pp. 452-462, 2002.
    • (2002) Proc. SPIE , vol.4684 , pp. 452-462
    • Bosch, J.G.1    Mitchell, S.C.2    Lelieveldt, B.P.F.3
  • 15
    • 0037516834 scopus 로고    scopus 로고
    • 3-D active appearance models: Segmentation of cardiac MR and ultrasound images
    • S. C. Mitchell, J. G. Bosch, B. P. F. Lelieveldt, et al., "3-D Active Appearance Models: segmentation of cardiac MR and ultrasound images", IEEE Trans. Med. Imaging 21, pp. 1167-1178, 2002.
    • (2002) IEEE Trans. Med. Imaging , vol.21 , pp. 1167-1178
    • Mitchell, S.C.1    Bosch, J.G.2    Lelieveldt, B.P.F.3
  • 16
    • 0002476649 scopus 로고
    • Application of point distribution models to the automated analysis of echocardiograms
    • A. Murray, ed., IEEE, Los Alamitos, CA
    • A. D. Parker, A. Hill, C. J. Taylor et al., "Application of point distribution models to the automated analysis of echocardiograms", in Computers in Cardiol., A. Murray, ed., pp. 25-28, IEEE, Los Alamitos, CA, 1994.
    • (1994) Computers in Cardiol. , pp. 25-28
    • Parker, A.D.1    Hill, A.2    Taylor, C.J.3
  • 17
    • 0035324512 scopus 로고    scopus 로고
    • Multistage hybrid Active Appearance Model matching: Segmentation of left and right ventricles in cardiac MR images
    • S. C. Mitchell, B. P. F. Lelieveldt et al., "Multistage hybrid Active Appearance Model matching: segmentation of left and right ventricles in cardiac MR images", IEEE Trans. Med. Imaging 20, pp. 415-423, 2001.
    • (2001) IEEE Trans. Med. Imaging , vol.20 , pp. 415-423
    • Mitchell, S.C.1    Lelieveldt, B.P.F.2
  • 18
    • 0000142472 scopus 로고
    • Procrustes methods in the statistical analysis of shape
    • C. Goodall, "Procrustes methods in the statistical analysis of shape," J. Royal Stat. Soc. B., 53, pp. 285-339, 1991.
    • (1991) J. Royal Stat. Soc. B. , vol.53 , pp. 285-339
    • Goodall, C.1
  • 19
    • 0036145159 scopus 로고    scopus 로고
    • Myocardial viability: Impact on left ventricular dilatation after acute myocardial infarction
    • F. Nijland, O. Kamp, P. M. J. Verhorst, W. G. de Voogt, H. G. Bosch, C. A. Visser, "Myocardial viability: impact on left ventricular dilatation after acute myocardial infarction", Heart 87, pp. 17-22, 2002.
    • (2002) Heart , vol.87 , pp. 17-22
    • Nijland, F.1    Kamp, O.2    Verhorst, P.M.J.3    De Voogt, W.G.4    Bosch, H.G.5    Visser, C.A.6
  • 20
    • 0031756401 scopus 로고    scopus 로고
    • Real-time strain rate imaging of the left ventricle by ultrasound
    • A. Heimdal, A. Stoylen, H. Torp, T. Skjaerpe, "Real-time strain rate imaging of the left ventricle by ultrasound", J. Am. Soc. Echocardiogr. 11, pp. 1013-1019, 1998.
    • (1998) J. Am. Soc. Echocardiogr. , vol.11 , pp. 1013-1019
    • Heimdal, A.1    Stoylen, A.2    Torp, H.3    Skjaerpe, T.4
  • 21
    • 0033840682 scopus 로고    scopus 로고
    • Use of peak systolic strain as an index of regional left ventricular function: Comparison with tissue Doppler velocity during dobutamine stress and myocardial ischemia
    • G. Armstrong, A. Pasquet, K. Fukamachi, et al., "Use of peak systolic strain as an index of regional left ventricular function: Comparison with tissue Doppler velocity during dobutamine stress and myocardial ischemia", J. Am. Soc. Echocardiogr. 13, pp. 731-737, 2000.
    • (2000) J. Am. Soc. Echocardiogr. , vol.13 , pp. 731-737
    • Armstrong, G.1    Pasquet, A.2    Fukamachi, K.3
  • 22
    • 0041874947 scopus 로고    scopus 로고
    • Left ventricle contour detection in X-ray angiograms using multi-view active appearance models
    • in Medical Imaging 2003: Image Processing, M. Sonka, J. M. Fitzpatrick, eds., (this volume)
    • C. R. Oost, B. P. F. Lelieveldt, G. Koning, M. Sonka, J. H. C. Reiber, "Left ventricle contour detection in X-ray angiograms using Multi-View Active Appearance Models", in Medical Imaging 2003: Image Processing, M. Sonka, J. M. Fitzpatrick, eds., Proc. SPIE 5032, (this volume), 2003.
    • (2003) Proc. SPIE , vol.5032
    • Oost, C.R.1    Lelieveldt, B.P.F.2    Koning, G.3    Sonka, M.4    Reiber, J.H.C.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.