메뉴 건너뛰기




Volumn 5032 I, Issue , 2003, Pages 177-182

Effect of the number of cases in image database on the performance of computer-aided diagnosis (CAD) for the detection of pulmonary nodules in chest radiographs

Author keywords

Chest radiograph; Computer aided diagnosis; Detection; Image database; Lung nodule; Number of cases

Indexed keywords

COMPUTER AIDED DESIGN; DATABASE SYSTEMS; IMAGE ANALYSIS; RADIOGRAPHY;

EID: 0042376077     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.480234     Document Type: Conference Paper
Times cited : (7)

References (15)
  • 1
    • 0023890921 scopus 로고
    • Image feature analysis and computer-aided diagnosis in digital radiography. 3. Automated detection of nodules in peripheral lung field
    • Giger ML, Doi K, MacMahon H, "Image feature analysis and computer-aided diagnosis in digital radiography. 3. Automated detection of nodules in peripheral lung field", Med Phys 15, 158-166, 1988.
    • (1988) Med Phys , vol.15 , pp. 158-166
    • Giger, M.L.1    Doi, K.2    MacMahon, H.3
  • 3
    • 0022536042 scopus 로고
    • Computerized search of chest radiographs for nodules
    • Lampeter WA, Wandtke JC, "Computerized search of chest radiographs for nodules", Invest Radiol 21, 384-390, 1986.
    • (1986) Invest Radiol , Issue.21 , pp. 384-390
    • Lampeter, W.A.1    Wandtke, J.C.2
  • 4
    • 33744808513 scopus 로고
    • Automatic lung nodule detection using profile matching and back-propagation neural network techniques
    • Lo SCB, Freedman MT, Lin JSJ, Mun SK, "Automatic lung nodule detection using profile matching and back-propagation neural network techniques", J Digit Imaging 6(1), 48-54, 1993.
    • (1993) J Digit Imaging , vol.6 , Issue.1 , pp. 48-54
    • Lo, S.C.B.1    Freedman, M.T.2    Lin, J.S.J.3    Mun, S.K.4
  • 5
    • 0030867439 scopus 로고    scopus 로고
    • Development of an improved CAD scheme for automated detection of lung nodules in digital chest images
    • Xu XW, Doi K, Kobayashi T, MacMahon H, Giger ML, "Development of an improved CAD scheme for automated detection of lung nodules in digital chest images", Med Phys 24, 1395-1403, 1997.
    • (1997) Med Phys , vol.24 , pp. 1395-1403
    • Xu, X.W.1    Doi, K.2    Kobayashi, T.3    MacMahon, H.4    Giger, M.L.5
  • 6
    • 0031732622 scopus 로고    scopus 로고
    • Computer-aided diagnoses: Automatic detection of lung nodules
    • Carreira MJ, Cabello D, Penedo MG, Mosquera A, "Computer-aided diagnoses: automatic detection of lung nodules", Med Phys 25(10), 1998-2006, 1998.
    • (1998) Med Phys , vol.25 , Issue.10 , pp. 1998-2006
    • Carreira, M.J.1    Cabello, D.2    Penedo, M.G.3    Mosquera, A.4
  • 7
    • 0020606057 scopus 로고
    • Lung cancer detected during a screening program using four-month chest radiographs
    • Muhm JR, Miller WE, Fontana RS, Sanderson DR, Uhlenhopp MA, "Lung cancer detected during a screening program using four-month chest radiographs", Radiology 148, 609-615, 1983.
    • (1983) Radiology , vol.148 , pp. 609-615
    • Muhm, J.R.1    Miller, W.E.2    Fontana, R.S.3    Sanderson, D.R.4    Uhlenhopp, M.A.5
  • 8
    • 0026513806 scopus 로고
    • Missed bronchogenic carcinoma: Radiographic findings in 27 patients with a potentially resectable lesion evident in retrospect
    • Austin JHM, Romney BM, Goldsmith LS, "Missed bronchogenic carcinoma: Radiographic findings in 27 patients with a potentially resectable lesion evident in retrospect", Radiology 182, 115-122, 1992.
    • (1992) Radiology , vol.182 , pp. 115-122
    • Austin, J.H.M.1    Romney, B.M.2    Goldsmith, L.S.3
  • 9
    • 0027983046 scopus 로고
    • Effect of case selection on the performance of computer-aided detection scheme
    • Nishikawa RM, Giger ML, Doi K, et al., "Effect of case selection on the performance of computer-aided detection scheme", Med Phys 21(2), 265-269, 1994.
    • (1994) Med Phys , vol.21 , Issue.2 , pp. 265-269
    • Nishikawa, R.M.1    Giger, M.L.2    Doi, K.3
  • 10
    • 0033461791 scopus 로고    scopus 로고
    • Classifier design for computer-aided diagnosis: Effects of finite sample size on the mean performance of classical and neural network classifiers
    • Chan HP, Sahiner B, Wagner RF, Petrick N, "Classifier design for computer-aided diagnosis: Effects of finite sample size on the mean performance of classical and neural network classifiers", Med Phys 26, 2654-2668, 1999.
    • (1999) Med Phys , vol.26 , pp. 2654-2668
    • Chan, H.P.1    Sahiner, B.2    Wagner, R.F.3    Petrick, N.4
  • 11
    • 0033986483 scopus 로고    scopus 로고
    • Development of a digital image database for chest radiographs with and without a lung nodule: Receiver operating characteristic analysis of radiologists' detection of pulmonary nodules
    • Shiraishi J, Katsuragawa S, Ikezoe J, et al., "Development of a digital image database for chest radiographs with and without a lung nodule: Receiver operating characteristic analysis of radiologists' detection of pulmonary nodules", AJR 174, 71-74, 2000.
    • (2000) AJR , vol.174 , pp. 71-74
    • Shiraishi, J.1    Katsuragawa, S.2    Ikezoe, J.3
  • 12
    • 0029039976 scopus 로고
    • Image feature analysis for computer-aided diagnosis: Accurate determination of ribcage boundary in chest radiographs
    • Xu XW, Doi K, "Image feature analysis for computer-aided diagnosis: Accurate determination of ribcage boundary in chest radiographs", Med Phys 22, 617-626, 1995.
    • (1995) Med Phys , vol.22 , pp. 617-626
    • Xu, X.W.1    Doi, K.2
  • 13
    • 0032764285 scopus 로고    scopus 로고
    • Iterative image warping technique for temporal subtraction of sequential chest radiographs to detect interval change
    • Ishida T, Katsuragawa S, Nakamura K, MacMahon H, Doi K, "Iterative image warping technique for temporal subtraction of sequential chest radiographs to detect interval change", Med Phys 26, 1320-1329, 1999.
    • (1999) Med Phys , vol.26 , pp. 1320-1329
    • Ishida, T.1    Katsuragawa, S.2    Nakamura, K.3    MacMahon, H.4    Doi, K.5
  • 14
    • 0025360533 scopus 로고
    • Image feature analysis and computer-aided diagnosis in digital radiography: Automated analysis of sizes of heart and lung in digital chest images
    • Nakamori N, Doi K, Sabeti V, MacMahon H, "Image feature analysis and computer-aided diagnosis in digital radiography: Automated analysis of sizes of heart and lung in digital chest images", Med Phys 17, 342-350, 1990.
    • (1990) Med Phys , vol.17 , pp. 342-350
    • Nakamori, N.1    Doi, K.2    Sabeti, V.3    Macmahon, H.4
  • 15
    • 0025269074 scopus 로고
    • Free-response methodology: Alternate analysis and a new observer-performance experiment
    • Chakraborty DP, Winter LH, "Free-response methodology: alternate analysis and a new observer-performance experiment", Radiology 174, 873-881, 1990.
    • (1990) Radiology , vol.174 , pp. 873-881
    • Chakraborty, D.P.1    Winter, L.H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.