메뉴 건너뛰기




Volumn 181, Issue 2, 2003, Pages 527-531

Stereotactic core needle biopsy of nonpalpable breast lesions using a conventional mammography unit with an add-on device

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTICLE; BREAST CANCER; BREAST TUMOR; COST EFFECTIVENESS ANALYSIS; DEVICE; DIAGNOSTIC ACCURACY; DIAGNOSTIC VALUE; EXCISION; FEMALE; FOLLOW UP; HISTOPATHOLOGY; HUMAN; HUMAN TISSUE; MAJOR CLINICAL STUDY; MAMMOGRAPHY; NEEDLE BIOPSY; PRIORITY JOURNAL; PROSPECTIVE STUDY; RELIABILITY; SAFETY; SENSITIVITY AND SPECIFICITY; STEREOTAXIC SURGERY; SYNCOPE;

EID: 0042344969     PISSN: 0361803X     EISSN: None     Source Type: Journal    
DOI: 10.2214/ajr.181.2.1810527     Document Type: Article
Times cited : (16)

References (27)
  • 3
    • 0025179426 scopus 로고
    • Stereotactic breast biopsy with a biopsy gun
    • Parker SH, Lovin JD, Jobe WE, et al. Stereotactic breast biopsy with a biopsy gun. Radiology 1990;176:741-747
    • (1990) Radiology , vol.176 , pp. 741-747
    • Parker, S.H.1    Lovin, J.D.2    Jobe, W.E.3
  • 4
    • 0025886119 scopus 로고
    • Non-palpable breast lesions: Stereotactic automated large core biopsies
    • Parker SH, Lovin JD, Jobe WE, et al. Non-palpable breast lesions: stereotactic automated large core biopsies. Radiology 1991;180:403-407
    • (1991) Radiology , vol.180 , pp. 403-407
    • Parker, S.H.1    Lovin, J.D.2    Jobe, W.E.3
  • 5
    • 0027170041 scopus 로고
    • Non-palpable breast lesions: Correlation of stereotaxic large-core needle biopsy and surgical biopsy results
    • Elvecrog EL, Lechner MC, Nelson MT. Non-palpable breast lesions: correlation of stereotaxic large-core needle biopsy and surgical biopsy results. Radiology 1993;188:453-455
    • (1993) Radiology , vol.188 , pp. 453-455
    • Elvecrog, E.L.1    Lechner, M.C.2    Nelson, M.T.3
  • 6
    • 0028209564 scopus 로고
    • Breast biopsy: A comparative study of stereotaxically guided core and excisional techniques
    • Gisvold JJ, Goellner JR, Grant CS, et al. Breast biopsy: a comparative study of stereotaxically guided core and excisional techniques. AJR 1994;162:815-820
    • (1994) AJR , vol.162 , pp. 815-820
    • Gisvold, J.J.1    Goellner, J.R.2    Grant, C.S.3
  • 7
    • 0028506316 scopus 로고
    • Stereotactic core needle biopsy of mammographic breast lesions as a viable alternative to surgical biopsy
    • Mikhail RA, Nathan RC, Weiss M, et al. Stereotactic core needle biopsy of mammographic breast lesions as a viable alternative to surgical biopsy. Ann Surg Oncol 1994;1:363-367
    • (1994) Ann Surg Oncol , vol.1 , pp. 363-367
    • Mikhail, R.A.1    Nathan, R.C.2    Weiss, M.3
  • 9
    • 0028091666 scopus 로고
    • Percutaneous large-core breast biopsy: A multi-institutional study
    • Parker SH, Burbank F, Jackman RJ, et al. Percutaneous large-core breast biopsy: a multi-institutional study. Radiology 1994;193:359-364
    • (1994) Radiology , vol.193 , pp. 359-364
    • Parker, S.H.1    Burbank, F.2    Jackman, R.J.3
  • 10
    • 0027934580 scopus 로고
    • Stereotaxic large-core needle biopsy of 450 non-palpable breast lesions with surgical correlation in lesions with cancer or atypical hyperplasia
    • Jackman RJ, Nowels KW, Shepard MJ, Finkelstein SI, Marzoni FA. Stereotaxic large-core needle biopsy of 450 non-palpable breast lesions with surgical correlation in lesions with cancer or atypical hyperplasia. Radiology 1994;193:91-95
    • (1994) Radiology , vol.193 , pp. 91-95
    • Jackman, R.J.1    Nowels, K.W.2    Shepard, M.J.3    Finkelstein, S.I.4    Marzoni, F.A.5
  • 11
    • 0028048330 scopus 로고
    • Stereotaxic needle core biopsy of breast lesions using a regular mammographic table with an adaptable stereotaxic device
    • Caines JS, McPhee MD, Konok GP, Wright BA. Stereotaxic needle core biopsy of breast lesions using a regular mammographic table with an adaptable stereotaxic device. AJR 1994;163:317-321
    • (1994) AJR , vol.163 , pp. 317-321
    • Caines, J.S.1    McPhee, M.D.2    Konok, G.P.3    Wright, B.A.4
  • 12
    • 0033065859 scopus 로고    scopus 로고
    • Decubitus stereotactic core biopsy of the breast: Technique and experience
    • Doyle AJ, Collins JP, Forkert CD. Decubitus stereotactic core biopsy of the breast: technique and experience. AJR 1999;172:688-690
    • (1999) AJR , vol.172 , pp. 688-690
    • Doyle, A.J.1    Collins, J.P.2    Forkert, C.D.3
  • 13
    • 0030846854 scopus 로고    scopus 로고
    • Adaptation of an add-on stereotaxic breast biopsy unit: Use of a dedicated reclinable mammography chair
    • Welle GJ, Clark ML. Adaptation of an add-on stereotaxic breast biopsy unit: use of a dedicated reclinable mammography chair. AJR 1997;169:1391-1393
    • (1997) AJR , vol.169 , pp. 1391-1393
    • Welle, G.J.1    Clark, M.L.2
  • 14
    • 0035178341 scopus 로고    scopus 로고
    • Stereotactic core biopsy of breast microcalcifications: Comparison of film versus digital mammography, both using an add-on unit
    • Becker L, Taves D, McCurdy L, Muscedere G, Karlik S, Ward S. Stereotactic core biopsy of breast microcalcifications: comparison of film versus digital mammography, both using an add-on unit. AJR 2001;177:1451-1457
    • (2001) AJR , vol.177 , pp. 1451-1457
    • Becker, L.1    Taves, D.2    McCurdy, L.3    Muscedere, G.4    Karlik, S.5    Ward, S.6
  • 15
    • 0035111496 scopus 로고    scopus 로고
    • Stereotactic core-needle biopsy: A multi-institutional prospective trial
    • Brenner RJ, Bassett LW, Fajardo LL, et al. Stereotactic core-needle biopsy: a multi-institutional prospective trial. Radiology 2001;218:866-872
    • (2001) Radiology , vol.218 , pp. 866-872
    • Brenner, R.J.1    Bassett, L.W.2    Fajardo, L.L.3
  • 16
    • 0033026699 scopus 로고    scopus 로고
    • Stereotactic 14 gauge core biopsy of non-palpable breast carcinoma: What is the relationship between the number of core samples taken and the sensitivity for detection of malignancy?
    • Rich PM, Michell MJ, Humphreys S, Howes GP, Nunnerley HB. Stereotactic 14 gauge core biopsy of non-palpable breast carcinoma: what is the relationship between the number of core samples taken and the sensitivity for detection of malignancy? Clin Radiol 1999;54:384-389
    • (1999) Clin Radiol , vol.54 , pp. 384-389
    • Rich, P.M.1    Michell, M.J.2    Humphreys, S.3    Howes, G.P.4    Nunnerley, H.B.5
  • 18
    • 0030023162 scopus 로고    scopus 로고
    • Stereotaxic core needle biopsy of breast microcalcifications: Correlation of target accuracy and diagnosis with lesion size
    • Mainiero MB, Philpotts LE, Lee CH, Lange RC, Carter D, Tocino I. Stereotaxic core needle biopsy of breast microcalcifications: correlation of target accuracy and diagnosis with lesion size. Radiology 1996;198:665-669
    • (1996) Radiology , vol.198 , pp. 665-669
    • Mainiero, M.B.1    Philpotts, L.E.2    Lee, C.H.3    Lange, R.C.4    Carter, D.5    Tocino, I.6
  • 19
    • 13344259979 scopus 로고    scopus 로고
    • Percutaneous core biopsy of the breast: Effect of operator experience and the number of samples on diagnostic accuracy
    • Brenner RJ, Fajardo LL, Fisher PR, et al. Percutaneous core biopsy of the breast: effect of operator experience and the number of samples on diagnostic accuracy. AJR 1996;166:341-346
    • (1996) AJR , vol.166 , pp. 341-346
    • Brenner, R.J.1    Fajardo, L.L.2    Fisher, P.R.3
  • 20
    • 0030921692 scopus 로고    scopus 로고
    • Stereotactic biopsy: Advantages and limitations
    • Dershaw, DD. Stereotactic biopsy: advantages and limitations. Breast J 1997;3:215-219
    • (1997) Breast J , vol.3 , pp. 215-219
    • Dershaw, D.D.1
  • 21
    • 0033008296 scopus 로고    scopus 로고
    • Follow-up of lesions diagnosed as benign by stereotaxic core needle biopsy: Frequency of mammographic change and false negative rate
    • Lee CH, Philpotts LE, Tocino I, Horvath LJ. Follow-up of lesions diagnosed as benign by stereotaxic core needle biopsy: frequency of mammographic change and false negative rate. Radiology 1999;212:189-194
    • (1999) Radiology , vol.212 , pp. 189-194
    • Lee, C.H.1    Philpotts, L.E.2    Tocino, I.3    Horvath, L.J.4
  • 22
    • 0031000837 scopus 로고    scopus 로고
    • Analysis of cancers not diagnosed at stereotactic core breast biopsy
    • Liberman L, Dershaw DD, Glassman JR, et al. Analysis of cancers not diagnosed at stereotactic core breast biopsy. Radiology 1997;203:151-157
    • (1997) Radiology , vol.203 , pp. 151-157
    • Liberman, L.1    Dershaw, D.D.2    Glassman, J.R.3
  • 23
    • 0031951594 scopus 로고    scopus 로고
    • Compliance with recommended follow-up after percutaneous breast core biopsy
    • Goodman KA, Birdwell RL, Ikeda DM. Compliance with recommended follow-up after percutaneous breast core biopsy. AJR 1998;170:89-92
    • (1998) AJR , vol.170 , pp. 89-92
    • Goodman, K.A.1    Birdwell, R.L.2    Ikeda, D.M.3
  • 25
  • 26
    • 0001214925 scopus 로고    scopus 로고
    • Accuracy of sampling microcalcifications by three stereotactic breast biopsy methods
    • abstr.
    • Jackman RJ, Burbank FH, Parker SH, et al. Accuracy of sampling microcalcifications by three stereotactic breast biopsy methods. (abstr.) Radiology 1997;205P:325
    • (1997) Radiology , vol.205 P , pp. 325
    • Jackman, R.J.1    Burbank, F.H.2    Parker, S.H.3
  • 27
    • 0041991072 scopus 로고    scopus 로고
    • Stereotactic breast biopsy of atypical ductal hyperplasia and ductal carcinoma in situ lesions: Improved accuracy with directional vacuum-assisted breast biopsy
    • Burbank F. Stereotactic breast biopsy of atypical ductal hyperplasia and ductal carcinoma in situ lesions: improved accuracy with directional vacuum-assisted breast biopsy. Radiology 1998;208:251-260
    • (1998) Radiology , vol.208 , pp. 251-260
    • Burbank, F.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.