메뉴 건너뛰기




Volumn 102, Issue 1, 2003, Pages 29-38

Evaluation of two portable lead-monitoring methods at mining sites

Author keywords

Anodic stripping voltammetry; Lead; Portable analysis; Ultrasonic extraction; X ray fluorescence

Indexed keywords

ESTERS; FLUORESCENCE; MINING; SILICATES; X RAY ANALYSIS;

EID: 0042330174     PISSN: 03043894     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0304-3894(03)00200-0     Document Type: Article
Times cited : (20)

References (21)
  • 1
    • 0003920055 scopus 로고
    • The metals
    • G.D. Clayton, F.E. Clayton (Eds.), Wiley, New York, (Chapter 27)
    • R.P. Beliles, The metals, in: G.D. Clayton, F.E. Clayton (Eds.), Patty's Industrial Hygiene and Toxicology, fourth ed., vol. II, Pt. C, Wiley, New York, 1994 (Chapter 27).
    • (1994) Patty's Industrial Hygiene and Toxicology, Fourth Ed. , vol.2 , Issue.PART C
    • Beliles, R.P.1
  • 2
    • 85031067766 scopus 로고    scopus 로고
    • Method 7702
    • CDC/NIOSH, Publication no. 98-119, Cincinnati
    • ®), fourth ed., Suppl. 2, CDC/NIOSH, Publication no. 98-119 ( http://www.cdc.gov/niosh ), Cincinnati, 1998.
    • (1998) ®), Fourth Ed. , Issue.SUPPL. 2
  • 3
    • 85031073889 scopus 로고    scopus 로고
    • Method 7701
    • CDC/NIOSH, Publication no. 98-119, Cincinnati
    • ®), fourth ed., Suppl. 2, CDC/NIOSH, Publication no. 98-119, Cincinnati, 1998.
    • (1998) ®), Fourth Ed. , Issue.SUPPL. 2
  • 4
    • 0031756679 scopus 로고    scopus 로고
    • Ultrasonic extraction and field-portable anodic stripping voltammetry for the determination of lead in workplace air samples
    • Ashley K., Mapp K.J., Millson M. Ultrasonic extraction and field-portable anodic stripping voltammetry for the determination of lead in workplace air samples. Am. Ind. Hygiene Assoc. J. 59:1998;671.
    • (1998) Am. Ind. Hygiene Assoc. J. , vol.59 , pp. 671
    • Ashley, K.1    Mapp, K.J.2    Millson, M.3
  • 5
    • 0028991566 scopus 로고
    • Application of field-portable X-ray fluorescence spectrometers for field-screening air filters for metals
    • Bernick M.B., Campagna P.R. Application of field-portable X-ray fluorescence spectrometers for field-screening air filters for metals. J. Hazard. Mater. 43:1995;91.
    • (1995) J. Hazard. Mater. , vol.43 , pp. 91
    • Bernick, M.B.1    Campagna, P.R.2
  • 6
    • 0030273218 scopus 로고    scopus 로고
    • Monitoring surface and airborne inorganic contamination in the workplace by a field portable X-ray fluorescence spectrometer
    • Dost A.A. Monitoring surface and airborne inorganic contamination in the workplace by a field portable X-ray fluorescence spectrometer. Ann. Occup. Hygiene. 40:1996;589.
    • (1996) Ann. Occup. Hygiene , vol.40 , pp. 589
    • Dost, A.A.1
  • 7
    • 0032998283 scopus 로고    scopus 로고
    • Evaluation of a portable X-ray fluorescence instrument for the determination of lead in workplace air samples
    • Morley J.C., Clark C.S., Deddens J.A., Ashley K., Roda S. Evaluation of a portable X-ray fluorescence instrument for the determination of lead in workplace air samples. Appl. Occup. Environ. Hygiene. 14:1999;306.
    • (1999) Appl. Occup. Environ. Hygiene , vol.14 , pp. 306
    • Morley, J.C.1    Clark, C.S.2    Deddens, J.A.3    Ashley, K.4    Roda, S.5
  • 8
    • 84987553244 scopus 로고
    • Ultrasonic extraction and field-portable anodic stripping voltammetry of lead from environmental samples
    • Ashley K. Ultrasonic extraction and field-portable anodic stripping voltammetry of lead from environmental samples. Electroanalysis. 7:1995;1189.
    • (1995) Electroanalysis , vol.7 , pp. 1189
    • Ashley, K.1
  • 9
    • 0036178245 scopus 로고    scopus 로고
    • Field measurement of lead in workplace air and paint chip samples by ultrasonic extraction and portable anodic stripping voltammetry
    • Sussell A., Ashley K. Field measurement of lead in workplace air and paint chip samples by ultrasonic extraction and portable anodic stripping voltammetry. J. Environ. Monit. 4:2002;156.
    • (2002) J. Environ. Monit. , vol.4 , pp. 156
    • Sussell, A.1    Ashley, K.2
  • 10
    • 0001675618 scopus 로고
    • Analysis of silicate rocks using field-portable X-ray fluorescence instrumentation incorporating a mercury iodide detector: A preliminary assessment of analytical performance
    • Potts P.J., Webb P.C., Williams-Thorpe O. Analysis of silicate rocks using field-portable X-ray fluorescence instrumentation incorporating a mercury iodide detector: a preliminary assessment of analytical performance. Analyst. 120:1995;1273.
    • (1995) Analyst , vol.120 , pp. 1273
    • Potts, P.J.1    Webb, P.C.2    Williams-Thorpe, O.3
  • 11
    • 0035821440 scopus 로고    scopus 로고
    • Field portable XRF analysis of environmental samples
    • Kalnicky D.J., Singhvi R. Field portable XRF analysis of environmental samples. J. Hazard. Mater. 83:2001;93.
    • (2001) J. Hazard. Mater. , vol.83 , pp. 93
    • Kalnicky, D.J.1    Singhvi, R.2
  • 12
    • 0003219425 scopus 로고
    • ATSDR, Atlanta
    • Agency for Toxic Substances and Disease Registry (ATSDR), Toxicological Profile for Lead, ATSDR, Atlanta, 1992.
    • (1992) Toxicological Profile for Lead
  • 13
    • 85031068547 scopus 로고
    • Method 7082
    • CDC/NIOSH, Publication no. 94-113, Cincinnati
    • ®), fourth ed., CDC/NIOSH, Publication no. 94-113, Cincinnati, 1994.
    • (1994) ®), Fourth Ed.
  • 20
    • 0035821442 scopus 로고    scopus 로고
    • Field screening test methods - Performance criteria and performance characteristics
    • Song R., Schlecht P.C., Ashley K. Field screening test methods - performance criteria and performance characteristics. J. Hazard. Mater. 83:2001;29.
    • (2001) J. Hazard. Mater. , vol.83 , pp. 29
    • Song, R.1    Schlecht, P.C.2    Ashley, K.3
  • 21
    • 0036399927 scopus 로고    scopus 로고
    • New approaches for assessment of occupational exposure to metals using on-site measurement
    • Nygren O. New approaches for assessment of occupational exposure to metals using on-site measurement. J. Environ. Monit. 4:2002;623.
    • (2002) J. Environ. Monit. , vol.4 , pp. 623
    • Nygren, O.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.