메뉴 건너뛰기




Volumn 14, Issue 9, 2003, Pages 2345-2351

Serial determinations of absolute plasma volume with indocyanine green during hemodialysis

Author keywords

[No Author keywords available]

Indexed keywords

INDOCYANINE GREEN;

EID: 0042320427     PISSN: 10466673     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.ASN.0000082998.50730.FA     Document Type: Article
Times cited : (33)

References (22)
  • 2
    • 0023757086 scopus 로고
    • Differential inhibition of various deoxyribonucleic acid polymerases by Evans blue and aurintricarboxylic acid
    • Nakane H, Balzarini J, De Clercq E, Ono K: Differential inhibition of various deoxyribonucleic acid polymerases by Evans blue and aurintricarboxylic acid. Eur J Biochem 177: 91-96, 1988
    • (1988) Eur J Biochem , vol.177 , pp. 91-96
    • Nakane, H.1    Balzarini, J.2    De Clercq, E.3    Ono, K.4
  • 4
    • 0014335839 scopus 로고
    • Determination of blood volume using indocyanine green (Cardiogreen) dye
    • Bradley EC, Barr JW: Determination of blood volume using indocyanine green (Cardiogreen) dye. Life Sci 7: 1001-1007, 1968
    • (1968) Life Sci , vol.7 , pp. 1001-1007
    • Bradley, E.C.1    Barr, J.W.2
  • 5
    • 45349099858 scopus 로고
    • Indocyanine green: Observations on its physical properties, plasma decay and hepatic extraction
    • Cherrick GR, Stein SW, Leevy CM, Davidson CS: Indocyanine green: Observations on its physical properties, plasma decay and hepatic extraction. J Clin Invest 39: 592-600, 1978
    • (1978) J Clin Invest , vol.39 , pp. 592-600
    • Cherrick, G.R.1    Stein, S.W.2    Leevy, C.M.3    Davidson, C.S.4
  • 7
    • 0027174518 scopus 로고
    • Determination of plasma volume and total blood volume using indocyanine green: A short review
    • Henschen S, Busse MW, Zisowsky S, Panning B: Determination of plasma volume and total blood volume using indocyanine green: A short review. J Med 24: 10-27, 1993
    • (1993) J Med , vol.24 , pp. 10-27
    • Henschen, S.1    Busse, M.W.2    Zisowsky, S.3    Panning, B.4
  • 9
    • 0025092293 scopus 로고
    • A blood protein monitor for the continuous measurement of blood volume changes during haemodialysis
    • Schneditz D, Pogglitsch H, Horina J, Binswanger U: A blood protein monitor for the continuous measurement of blood volume changes during haemodialysis. Kidney Int 38: 342-346, 1990
    • (1990) Kidney Int , vol.38 , pp. 342-346
    • Schneditz, D.1    Pogglitsch, H.2    Horina, J.3    Binswanger, U.4
  • 10
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG: Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1: 307-310, 1986
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 11
    • 0023598267 scopus 로고
    • Determination of plasma volume with indocyanine green
    • Schad H, Haider H, Brechtelsbauer H: Determination of plasma volume with indocyanine green. Anaesthetist 36: 608-614, 1987
    • (1987) Anaesthetist , vol.36 , pp. 608-614
    • Schad, H.1    Haider, H.2    Brechtelsbauer, H.3
  • 12
    • 0024382574 scopus 로고
    • Adverse reaction to indocyanine green: A case report and a review of the literature
    • Benya R, Quintana J, Brundage B: Adverse reaction to indocyanine green: A case report and a review of the literature. Cathet Cardiovasc Diagn 17: 231-233, 1989
    • (1989) Cathet Cardiovasc Diagn , vol.17 , pp. 231-233
    • Benya, R.1    Quintana, J.2    Brundage, B.3
  • 13
    • 0014209306 scopus 로고
    • Indocyanine green clearance as a test for hepatic function: Evaluation by dichromatic ear densitometry
    • Leevy CM, Smth F, Longueville J, Paumgartner G, Howard VV: Indocyanine green clearance as a test for hepatic function: Evaluation by dichromatic ear densitometry. JAMA 200: 236-240, 1967
    • (1967) JAMA , vol.200 , pp. 236-240
    • Leevy, C.M.1    Smth, F.2    Longueville, J.3    Paumgartner, G.4    Howard, V.V.5
  • 15
    • 0043072514 scopus 로고
    • Methodological and actual error of plasma volume determination
    • Senn LY, Karlson KE: Methodological and actual error of plasma volume determination. Surgery 44: 1095-1105, 1958
    • (1958) Surgery , vol.44 , pp. 1095-1105
    • Senn, L.Y.1    Karlson, K.E.2
  • 16
    • 0017263577 scopus 로고
    • Light-absorbing properties, stability and spectral stabilization of indocyanine green
    • Landsman MLJ, Kwant G, Mook GA, Zijlstra WG: Light-absorbing properties, stability and spectral stabilization of indocyanine green. J Appl Physiol 40: 575-583, 1976
    • (1976) J Appl Physiol , vol.40 , pp. 575-583
    • Landsman, M.L.J.1    Kwant, G.2    Mook, G.A.3    Zijlstra, W.G.4
  • 17
    • 0016442891 scopus 로고
    • Red cell and plasma volumes in normal adults
    • Hurley PJ: Red cell and plasma volumes in normal adults. J Nucl Med 16: 46-52, 1975
    • (1975) J Nucl Med , vol.16 , pp. 46-52
    • Hurley, P.J.1
  • 18
    • 0025037656 scopus 로고
    • Determination of circulating blood volume by measurement of indocyanine green dye in hemolysate: A preliminary study
    • Busse MW, Zisowsky S, Henschen S, Panning B, Reilmann L: Determination of circulating blood volume by measurement of indocyanine green dye in hemolysate: A preliminary study. Life Sci 46: 647-652, 1990
    • (1990) Life Sci , vol.46 , pp. 647-652
    • Busse, M.W.1    Zisowsky, S.2    Henschen, S.3    Panning, B.4    Reilmann, L.5
  • 19
    • 0028025525 scopus 로고
    • Microvascular volume changes induced by exercise, heat exposure or endotoxin injection
    • Lee JS: Microvascular volume changes induced by exercise, heat exposure or endotoxin injection. Am J Physiol 267: H1142-H1150, 1994
    • (1994) Am J Physiol , vol.267
    • Lee, J.S.1
  • 20
    • 33744839368 scopus 로고
    • Clinical calorimetry: A formula to estimate surface area if height and weight be known
    • Dubois D, Dubois EF: Clinical calorimetry: A formula to estimate surface area if height and weight be known. Arch Intern Med 17: 863-891, 1916
    • (1916) Arch Intern Med , vol.17 , pp. 863-891
    • Dubois, D.1    Dubois, E.F.2
  • 22
    • 0002686456 scopus 로고
    • The use of the electronic digital computer to determine the best fit of blood volume formulas
    • Hidalgo JU, Nalder SB, Bloch T: The use of the electronic digital computer to determine the best fit of blood volume formulas. J Nucl Med 3: 94-99, 1962
    • (1962) J Nucl Med , vol.3 , pp. 94-99
    • Hidalgo, J.U.1    Nalder, S.B.2    Bloch, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.