Volumn 32, Issue 27, 2003, Pages 1263-1268

Complications with totally implantable venous access device: A retrospective study of 116 cases;Complications des chambres à cathéter implantables: Étude rétrospective de 116 cas

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ANESTHESIA INDUCTION; ARTICLE; CATHETER INFECTION; CONTROLLED STUDY; DEEP VEIN THROMBOSIS; DEVICE; FEMALE; FOLLOW UP; FRANCE; GENERAL ANESTHESIA; HEMATOMA; HUMAN; IMPLANTATION; INTERNAL JUGULAR VEIN; LOCAL ANESTHESIA; MAJOR CLINICAL STUDY; MALE; MEDICAL EDUCATION; POSTOPERATIVE COMPLICATION; RETROSPECTIVE STUDY; SEPTICEMIA; SUBCLAVIAN VEIN; TOTALLY IMPLANTABLE VENOUS ACCESS DEVICE;

EID: 0042320389     PISSN: 07554982     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (11)

References (30)
  • 1
    • 0026709536 scopus 로고
    • Totally implantable venous access ports, the patients' point of view. A quality control study
    • Borst CG, de Kruif AT, van Dam FS, de Graaf PW. Totally implantable venous access ports, the patients' point of view. A quality control study. Cancer Nurs 1992; 15: 378-81.
    • (1992) Cancer Nurs , vol.15 , pp. 378-381
    • Borst, C.G.1    De Kruif, A.T.2    Van Dam, F.S.3    De Graaf, P.W.4
  • 2
    • 0024371811 scopus 로고
    • Classical external indwelling central venous catheter versus totally implanted venous access systems for chemotherapy administration: A randomized trial in 100 patients with solid tumors
    • Carde P, Cosset-Delaigue MF, Laplanche A, Chareau I. Classical external indwelling central venous catheter versus totally implanted venous access systems for chemotherapy administration: a randomized trial in 100 patients with solid tumors. Eur J Cancer Clin Oncol 1989; 25: 939-44.
    • (1989) Eur J Cancer Clin Oncol , vol.25 , pp. 939-944
    • Carde, P.1    Cosset-Delaigue, M.F.2    Laplanche, A.3    Chareau, I.4
  • 3
    • 0024598557 scopus 로고
    • Experience with a totally implantable catheter in adult patients: A single institution retrospective study of 114 cases
    • Defraigne JO, Closon MT, Bruyninx L et al. Experience with a totally implantable catheter in adult patients: a single institution retrospective study of 114 cases. Eur J Surg Oncol 1989; 15: 61-4.
    • (1989) Eur J Surg Oncol , vol.15 , pp. 61-64
    • Defraigne, J.O.1    Closon, M.T.2    Bruyninx, L.3
  • 4
    • 0035523214 scopus 로고    scopus 로고
    • Dispositifs intraveineux de longue durée et soins à domicile
    • Nov
    • Trabacchi G. Dispositifs intraveineux de longue durée et soins à domicile. Soins 2001 Nov; (660): 33.
    • (2001) Soins , Issue.660 , pp. 33
    • Trabacchi, G.1
  • 5
    • 0034950972 scopus 로고    scopus 로고
    • Évaluation des sites implantables en cancérologie médicale en tunisie. Etude prospective à propos de 205 cas
    • Boussen H, Mtaallah M, Dhiab T et al. Évaluation des sites implantables en cancérologie médicale en tunisie. Etude prospective à propos de 205 cas. Ann Fr Anesth Reanim 2001; 20: 509-13.
    • (2001) Ann Fr Anesth Reanim , vol.20 , pp. 509-513
    • Boussen, H.1    Mtaallah, M.2    Dhiab, T.3
  • 6
    • 0029806498 scopus 로고    scopus 로고
    • Surveillance épidémiologique des infections de cathéters à chambre implantable
    • Mallaret M. R, Olive F, Fauconnier J et al. Surveillance épidémiologique des infections de cathéters à chambre implantable. Méd Mal Infect 1996; 26: 752-6.
    • (1996) Méd Mal Infect , vol.26 , pp. 752-756
    • Mallaret, M.R.1    Olive, F.2    Fauconnier, J.3
  • 7
    • 0027377706 scopus 로고
    • Infectious morbidity associated with long-term use of venous access devices in patients with cancer
    • Groegger JS, Lucas AB, Thaler HT et al. Infectious morbidity associated with long-term use of venous access devices in patients with cancer. Ann Intern Med 1993; 119: 1168-74.
    • (1993) Ann Intern Med , vol.119 , pp. 1168-1174
    • Groegger, J.S.1    Lucas, A.B.2    Thaler, H.T.3
  • 8
    • 0029569131 scopus 로고
    • Complication inhabituelle de l'utilisation des chambres implantables en oncologie
    • Coton T, Bonnet D, Pinot JJ et al. Complication inhabituelle de l'utilisation des chambres implantables en oncologie. Rev Pneumol Clin 1995; 51: 351-3.
    • (1995) Rev Pneumol Clin , vol.51 , pp. 351-353
    • Coton, T.1    Bonnet, D.2    Pinot, J.J.3
  • 9
    • 0028769107 scopus 로고
    • Cancérologie cervico-faciale: Complications des systèmes d'accès veineux implantable, étude rétrospective
    • Paoli C, Bassot V, el-Bez M. et al. Cancérologie cervico-faciale: complications des systèmes d'accès veineux implantable, étude rétrospective. Presse Med 1994; 23: 649-52.
    • (1994) Presse Med , vol.23 , pp. 649-652
    • Paoli, C.1    Bassot, V.2    El-Bez, M.3
  • 10
    • 0030332489 scopus 로고    scopus 로고
    • Complications of an implantable venous access device (Port-a-Cath) during intermittent continuous infusion of chemotherapy
    • Poorter RL, Lauw FN, Bemelman WA, Bakker PJ, Taat CW, Veenhof CH. Complications of an implantable venous access device (Port-a-Cath) during intermittent continuous infusion of chemotherapy. Eur J Cancer 1996; 32: 2262-6.
    • (1996) Eur J Cancer , vol.32 , pp. 2262-2266
    • Poorter, R.L.1    Lauw, F.N.2    Bemelman, W.A.3    Bakker, P.J.4    Taat, C.W.5    Veenhof, C.H.6
  • 11
    • 0030870183 scopus 로고    scopus 로고
    • Radiologic placement of subcutaneous infusion chest ports for long-term central venous access
    • Funaki B, Szymski GX, Hackworth CA et al. Radiologic placement of subcutaneous infusion chest ports for long-term central venous access. AJR 1997; 169: 1431-4.
    • (1997) AJR , vol.169 , pp. 1431-1434
    • Funaki, B.1    Szymski, G.X.2    Hackworth, C.A.3
  • 12
    • 0026718804 scopus 로고
    • Radiology-assisted placement of implantable subcutaneous infusion ports for long-term venous access
    • Morris SL, Jaques PF, Mauro MA. Radiology-assisted placement of implantable subcutaneous infusion ports for long-term venous access. Radiologie 1992; 184: 149-51.
    • (1992) Radiologie , vol.184 , pp. 149-151
    • Morris, S.L.1    Jaques, P.F.2    Mauro, M.A.3
  • 13
    • 0034774986 scopus 로고    scopus 로고
    • Totally implantable venous access devices implanted surgically: A retrospective study on early and late complications
    • Di Carlo I, Cordio S, La Greca G et al. Totally implantable venous access devices implanted surgically: a retrospective study on early and late complications. Arch Surg 2001; 136: 1050-3.
    • (2001) Arch Surg , vol.136 , pp. 1050-1053
    • Di Carlo, I.1    Cordio, S.2    La Greca, G.3
  • 14
    • 0032866834 scopus 로고    scopus 로고
    • Silicone venous access devices positioned with their tips high in the superior vena cava are more likely to malfunction
    • Petersen J, Delaney JH, Brakstad MT, Rowbotham RK, Bagley CM Jr. Silicone venous access devices positioned with their tips high in the superior vena cava are more likely to malfunction. Am J Surg 1999;178:38-41.
    • (1999) Am J Surg , vol.178 , pp. 38-41
    • Petersen, J.1    Delaney, J.H.2    Brakstad, M.T.3    Rowbotham, R.K.4    Bagley C.M., Jr.5
  • 15
    • 0030913089 scopus 로고    scopus 로고
    • Cathéters veineux centraux. Surveillance prospective sur l'ensemble d'un hôpital
    • Barbut F, Guiguet M, Reynaud F et al. Cathéters veineux centraux. Surveillance prospective sur l'ensemble d'un hôpital. Presse Med 1997; 26: 656-62.
    • (1997) Presse Med , vol.26 , pp. 656-662
    • Barbut, F.1    Guiguet, M.2    Reynaud, F.3
  • 16
    • 0029116419 scopus 로고
    • A randomized, controlled trial of the efficacy of a heparin and vancomycin solution in preventing central venous catheter infections in children
    • Rackoff WR, Weiman M, Jakobowski D et al. A randomized, controlled trial of the efficacy of a heparin and vancomycin solution in preventing central venous catheter infections in children. J Pediatr 1995; 127: 147-51.
    • (1995) J Pediatr , vol.127 , pp. 147-151
    • Rackoff, W.R.1    Weiman, M.2    Jakobowski, D.3
  • 17
    • 0031876363 scopus 로고    scopus 로고
    • Place du verrou antibiotique dans le traitement des infections de chambre à cathéter implantable
    • Brion J P, Barnoud D, Mallaret M. R. Place du verrou antibiotique dans le traitement des infections de chambre à cathéter implantable. Med Mal Infect 1998; 28: 461-8
    • (1998) Med Mal Infect , vol.28 , pp. 461-468
    • Brion, J.P.1    Barnoud, D.2    Mallaret, M.R.3
  • 18
    • 0023760748 scopus 로고
    • Internal jugular and subclavian vein thrombosis caused by central venous catheters. Evaluation using Doppler blood flow imaging
    • Hubsch PJ, Stiglbauer RL, Schwaighofer BW, Kainberger FM, Barton PR. Internal jugular and subclavian vein thrombosis caused by central venous catheters. Evaluation using Doppler blood flow imaging. J Ultrasound Med 1988; 7: 629-36.
    • (1988) J Ultrasound Med , vol.7 , pp. 629-636
    • Hubsch, P.J.1    Stiglbauer, R.L.2    Schwaighofer, B.W.3    Kainberger, F.M.4    Barton, P.R.5
  • 19
    • 0029875357 scopus 로고    scopus 로고
    • Experimental prevention of deep venous thrombosis with low-molecular-weight heparin using implantable infusion devices
    • Pucheu A, Leduc B, Sillet-Bach I, Payen C, Assaf W, Pucheu M. Experimental prevention of deep venous thrombosis with low-molecular-weight heparin using implantable infusion devices. Ann Cardiol Angeiol 1996; 45: 59-63.
    • (1996) Ann Cardiol Angeiol , vol.45 , pp. 59-63
    • Pucheu, A.1    Leduc, B.2    Sillet-Bach, I.3    Payen, C.4    Assaf, W.5    Pucheu, M.6
  • 20
    • 0030321582 scopus 로고    scopus 로고
    • Etude rétrospective des thromboses de la reine sous-clavière après mise en place d'un système d'accès veineux implantable en cancérologie cervico-faciale
    • Bonfils P, Luciani JA, Potard G, Bassot V. Etude rétrospective des thromboses de la reine sous-clavière après mise en place d'un système d'accès veineux implantable en cancérologie cervico-faciale. Ann Otolaryngol Chir Cervicofac 1996; 113: 425-9.
    • (1996) Ann Otolaryngol Chir Cervicofac , vol.113 , pp. 425-429
    • Bonfils, P.1    Luciani, J.A.2    Potard, G.3    Bassot, V.4
  • 21
    • 0029881245 scopus 로고    scopus 로고
    • Fibrinolyse des thromboses veineuses profondes sur dispositifs de perfusion implantable. Å propos d'une série consécutive de 57 thromboses et de 32 fibrinolyses
    • Pucheu A, Dierhas M, Leduc B et al. Fibrinolyse des thromboses veineuses profondes sur dispositifs de perfusion implantable. Å propos d'une série consécutive de 57 thromboses et de 32 fibrinolyses. Bull Cancer 1996; 83: 293-9.
    • (1996) Bull Cancer , vol.83 , pp. 293-299
    • Pucheu, A.1    Dierhas, M.2    Leduc, B.3
  • 22
  • 24
    • 0031672239 scopus 로고    scopus 로고
    • Central venous catheter related thrombosis in children: Analysis of the Canadian Registry of Venous Thromboembolic Complications
    • Massicotte MP, Dix D, Monagle P, Adams M, Andrew M. Central venous catheter related thrombosis in children: analysis of the Canadian Registry of Venous Thromboembolic Complications. J Pediatr 1998; 133: 770-6.
    • (1998) J Pediatr , vol.133 , pp. 770-776
    • Massicotte, M.P.1    Dix, D.2    Monagle, P.3    Adams, M.4    Andrew, M.5
  • 25
    • 0035901061 scopus 로고    scopus 로고
    • Thromboses veineuses sur cathéters centraux en cancérologie
    • Gratadou D, Elias A, Elias M, Boccalon H. Thromboses veineuses sur cathéters centraux en cancérologie, Presse Med 2001; 30: 298-301.
    • (2001) Presse Med , vol.30 , pp. 298-301
    • Gratadou, D.1    Elias, A.2    Elias, M.3    Boccalon, H.4
  • 26
    • 0025237877 scopus 로고
    • Very low doses of warfarin can prevent thrombosis in central venous catheters. A randomised prospective trial
    • Bern M, Lokich J, Wallach S et al. Very low doses of warfarin can prevent thrombosis in central venous catheters. A randomised prospective trial. Ann Intern Med 1990; 112: 423-8.
    • (1990) Ann Intern Med , vol.112 , pp. 423-428
    • Bern, M.1    Lokich, J.2    Wallach, S.3
  • 28
    • 0022049762 scopus 로고
    • Cathéters totalement implantables pour chimiothérapie anticancéreuse. Expérience française de 325 cas
    • Champault G. Cathéters totalement implantables pour chimiothérapie anticancéreuse. Expérience française de 325 cas. J Chir (Paris) 1985; 122: 269-72.
    • (1985) J Chir (Paris) , vol.122 , pp. 269-272
    • Champault, G.1
  • 29
    • 0028311049 scopus 로고
    • Réflexions sur l'entretien des sites de perfusion totalement implantables
    • Bazelly B, Lotz JP, Milleron B. Réflexions sur l'entretien des sites de perfusion totalement implantables. Rev Pneumo Clin 1994; 50:43-4.
    • (1994) Rev Pneumo Clin , vol.50 , pp. 43-44
    • Bazelly, B.1    Lotz, J.P.2    Milleron, B.3