메뉴 건너뛰기




Volumn 23, Issue 3, 2003, Pages 213-220

Computerized calculation scheme for bitoric eikonic intraocular lenses

Author keywords

Bitoric intraocular lens; Calculation scheme; Eikonic lens; Optimization algorithm; Paraxial ray tracing

Indexed keywords

ALGORITHM; ARTICLE; CALCULATION; COMPUTER ANALYSIS; IMAGE DISPLAY; LENS IMPLANT; PRIORITY JOURNAL; ASTIGMATISM; HUMAN; PROSTHESIS;

EID: 0042286436     PISSN: 02755408     EISSN: None     Source Type: Journal    
DOI: 10.1046/j.1475-1313.2003.00109.x     Document Type: Article
Times cited : (21)

References (18)
  • 3
    • 0027430138 scopus 로고
    • Magnification and visual acuity in refractive surgery
    • Applegate, R. A. and Howland H. C. (1993) Magnification and visual acuity in refractive surgery. Arch. Ophthalmol. 111, 1335-1342.
    • (1993) Arch. Ophthalmol. , vol.111 , pp. 1335-1342
    • Applegate, R.A.1    Howland, H.C.2
  • 4
    • 0022446359 scopus 로고
    • Two simple calculation schemes for use in ophthalmic optics. I. Tracing oblique rays through systems including astigmatic surfaces
    • Bennett, A. G. (1986a) Two simple calculation schemes for use in ophthalmic optics. I. Tracing oblique rays through systems including astigmatic surfaces. Ophthal. Physiol. Opt. 6, 325-331.
    • (1986) Ophthal. Physiol. Opt. , vol.6 , pp. 325-331
    • Bennett, A.G.1
  • 5
    • 0022885345 scopus 로고
    • Two simple calculation schemes for use in ophthalmic optics. II. Tracing axial pencils through systems including astigmatic surfaces at random axes
    • Bennett, A. G. (1986b) Two simple calculation schemes for use in ophthalmic optics. II. Tracing axial pencils through systems including astigmatic surfaces at random axes. Ophthal. Physiol. Opt. 6, 419-429.
    • (1986) Ophthal. Physiol. Opt. , vol.6 , pp. 419-429
    • Bennett, A.G.1
  • 6
    • 0028105856 scopus 로고
    • A study of the axis of orientation of residual astigmatism
    • Dunne, M. C., Elawad, M. E. and Barnes, D. A. (1994) A study of the axis of orientation of residual astigmatism. Acta Ophthalmol. (Copenh) 72, 483-489.
    • (1994) Acta Ophthalmol. (Copenh) , vol.72 , pp. 483-489
    • Dunne, M.C.1    Elawad, M.E.2    Barnes, D.A.3
  • 7
    • 0030950313 scopus 로고    scopus 로고
    • Determination of the influence of effectivity upon residual astigmatism
    • Dunne, M. C., Elawad, M. E. and Barnes, D. A. (1997) Determination of the influence of effectivity upon residual astigmatism. Acta Ophthalmol. 75, 170-173.
    • (1997) Acta Ophthalmol. , vol.75 , pp. 170-173
    • Dunne, M.C.1    Elawad, M.E.2    Barnes, D.A.3
  • 8
    • 0033485784 scopus 로고    scopus 로고
    • Implantation of a toric poly(methyl methacrylate) intraocular lens to correct high astigmatism
    • Frohn, A., Dick, H. B. and Thiel, H. J. (1999) Implantation of a toric poly(methyl methacrylate) intraocular lens to correct high astigmatism. J. Cataract Refract. Surg. 25, 1675-1678.
    • (1999) J. Cataract Refract. Surg. , vol.25 , pp. 1675-1678
    • Frohn, A.1    Dick, H.B.2    Thiel, H.J.3
  • 9
    • 0018477103 scopus 로고
    • Eikonic lens design for minus prescriptions
    • Good, G. W. and Polasky, M. (1979) Eikonic lens design for minus prescriptions. Am. J. Ophthalmol. 56, 345-349.
    • (1979) Am. J. Ophthalmol. , vol.56 , pp. 345-349
    • Good, G.W.1    Polasky, M.2
  • 10
    • 0006282932 scopus 로고
    • Strahldurchrechnung in gaußscher optik
    • (eds Schott K., Jacobi K. W. and Freyler H.) Springer, Berlin
    • Haigis, W. (1991). Strahldurchrechnung in Gaußscher Optik. In: 4. DGII-Kongress (eds Schott K., Jacobi K. W. and Freyler H.) Springer, Berlin, pp. 233-246.
    • (1991) 4. DGII-Kongress , pp. 233-246
    • Haigis, W.1
  • 11
    • 0019725913 scopus 로고
    • A system matrix for astigmatic optical systems: I. Introduction and dioptric power relations
    • Keating, M. P. (1981a) A system matrix for astigmatic optical systems: I. Introduction and dioptric power relations. Am. J. Optom. Physiol. Opt. 58, 810-819.
    • (1981) Am. J. Optom. Physiol. Opt. , vol.58 , pp. 810-819
    • Keating, M.P.1
  • 12
    • 0019720266 scopus 로고
    • A system matrix for astigmatic optical systems: II. Corrected systems including an astigmatic eye
    • Keating, M. P. (1981b) A system matrix for astigmatic optical systems: II. Corrected systems including an astigmatic eye. Am. J. Optom. Physiol. Opt. 58, 919-929.
    • (1981) Am. J. Optom. Physiol. Opt. , vol.58 , pp. 919-929
    • Keating, M.P.1
  • 13
    • 0019991611 scopus 로고
    • A matrix formulation of spectacle magnification
    • Keating, M. P. (1982) A matrix formulation of spectacle magnification. Ophthal. Physiol. Opt. 2, 145-158.
    • (1982) Ophthal. Physiol. Opt. , vol.2 , pp. 145-158
    • Keating, M.P.1
  • 14
    • 0030807713 scopus 로고    scopus 로고
    • Intraocular lens power formula based on vergence calculation and lens design
    • Naeser, K. (1997) Intraocular lens power formula based on vergence calculation and lens design. J. Cataract Refract. Surg. 23, 1200-1207.
    • (1997) J. Cataract Refract. Surg. , vol.23 , pp. 1200-1207
    • Naeser, K.1
  • 15
    • 0033954769 scopus 로고    scopus 로고
    • Astigmatism and toric intraocular lenses
    • Novis, C. (2000) Astigmatism and toric intraocular lenses. Curr. Opin. Ophthalmol. 11, 47-50.
    • (2000) Curr. Opin. Ophthalmol. , vol.11 , pp. 47-50
    • Novis, C.1
  • 17
    • 0034076365 scopus 로고    scopus 로고
    • IOL power calculation in eyes after corneal refractive surgery
    • Seitz, B. and Langenbucher, A. (2000) IOL power calculation in eyes after corneal refractive surgery. J. Refract. Surg. 16, 349-361.
    • (2000) J. Refract. Surg. , vol.16 , pp. 349-361
    • Seitz, B.1    Langenbucher, A.2
  • 18
    • 0021012391 scopus 로고
    • Iseikonia and accommodation in the fellow eye in monocular IOL implantation
    • Wang, G. J. and Pomerantzeff, O. (1983) Iseikonia and accommodation in the fellow eye in monocular IOL implantation. Am. Intra-Ocular Implant Soc. J. 9, 441-444.
    • (1983) Am. Intra-Ocular Implant Soc. J. , vol.9 , pp. 441-444
    • Wang, G.J.1    Pomerantzeff, O.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.