메뉴 건너뛰기




Volumn 50, Issue 7, 2003, Pages 881-889

Two-Dimensional SPICE-Linked Multiresolution Impedance Method for Low-Frequency Electromagnetic Interactions

Author keywords

Dosimetry; electromagnetic modeling; induced fields; numerical modeling

Indexed keywords

ANIMAL; ARTICLE; BIOLOGICAL MODEL; BRAIN; COMPUTER PROGRAM; COMPUTER SIMULATION; ELECTRODE; ELECTROMAGNETIC FIELD; ELECTROSTIMULATION; EVALUATION; EYE; FINITE ELEMENT ANALYSIS; HUMAN; IMPEDANCE; METHODOLOGY; MUSCLE; PHYSIOLOGY; RADIOMETRY; REPRODUCIBILITY; RETINA; SENSITIVITY AND SPECIFICITY; VALIDATION STUDY;

EID: 0042163160     PISSN: 00189294     EISSN: 15582531     Source Type: Journal    
DOI: 10.1109/TBME.2003.813534     Document Type: Article
Times cited : (11)

References (7)
  • 1
    • 0021647965 scopus 로고
    • Impedance method for calculation of power deposition patterns in magnetically induced hyperthermia
    • O. P. Gandhi, J. F. DeFord, and H. Kanai, “Impedance method for calculation of power deposition patterns in magnetically induced hyperthermia,” IEEE Trans. Biomed. Eng., vol. BME-31, pp. 644-651, 1984.
    • (1984) IEEE Trans. Biomed. Eng. , vol.BME-31 , pp. 644-651
    • Gandhi, O.P.1    DeFord, J.F.2    Kanai, H.3
  • 2
    • 0020684954 scopus 로고
    • Radiofrequency-induced hyperthermia: computer simulation of specific absorption rate distributions using realistic anatomical models
    • D.W. Armitage, H. H. LeVeen, and R. Pethig, “Radiofrequency-induced hyperthermia: computer simulation of specific absorption rate distributions using realistic anatomical models,” Phys. Med. Biol., vol. 28, pp. 31-42, 1983.
    • (1983) Phys. Med. Biol. , vol.28 , pp. 31-42
    • Armitage, D.W.1    LeVeen, H.H.2    Pethig, R.3
  • 3
    • 0031910772 scopus 로고    scopus 로고
    • Induced current densities from low-frequency magnetic fields in a 2-mm resolution, anatomically realistic model of the body
    • P. J. Dimbylow, “Induced current densities from low-frequency magnetic fields in a 2-mm resolution, anatomically realistic model of the body,” Phys. Med. Biol., vol. 43, pp. 221-230, 1998.
    • (1998) Phys. Med. Biol. , vol.43 , pp. 221-230
    • Dimbylow, P.J.1
  • 4
    • 0030290769 scopus 로고    scopus 로고
    • Comparison of magnetically induced ELF fields in humans computed by FDTD and scalar potential FD codes
    • T. W. Dawson, J. De Moerloose, and M. A. Stuchly, “Comparison of magnetically induced ELF fields in humans computed by FDTD and scalar potential FD codes,” Appl. Computational Electromagn. Soc. J., vol. 11, pp. 63-71, 1996.
    • (1996) Appl. Computational Electromagn. Soc. J. , vol.11 , pp. 63-71
    • Dawson, T.W.1    De Moerloose, J.2    Stuchly, M.A.3
  • 5
    • 2642619659 scopus 로고    scopus 로고
    • A comparison of analytical and numerical solutions for induction in a sphere with equatorially varying conductivity by low-frequency uniform magnetic fields of arbitrary orientation
    • T. W. Dawson and M. A. Stuchly, “A comparison of analytical and numerical solutions for induction in a sphere with equatorially varying conductivity by low-frequency uniform magnetic fields of arbitrary orientation,” in Proc. 1997 Symp. Applied Computational Electromagnetics Society, pp. 533-540.
    • in Proc. 1997 Symp. Applied Computational Electromagnetics Society , pp. 533-540
    • Dawson, T.W.1    Stuchly, M.A.2
  • 7
    • 0035388587 scopus 로고    scopus 로고
    • Evaluation of modeling accuracy of power frequency field interactions with the human body
    • T. W. Dawson, M. Potter, and M. A. Stuchly, “Evaluation of modeling accuracy of power frequency field interactions with the human body,” Appl. Computational Electromagn. Soc. J., vol. 16, no. 2, 2001.
    • (2001) Appl. Computational Electromagn. Soc. J. , vol.16 , Issue.2
    • Dawson, T.W.1    Potter, M.2    Stuchly, M.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.