메뉴 건너뛰기




Volumn 5032 III, Issue , 2003, Pages 1810-1819

Filtered back-projection reconstruction technique for coherent-scatter computed tomography

Author keywords

Coherent Scatter Computed Tomography; CSCT; FBP; Filtered Back Projection

Indexed keywords

ALGORITHMS; DATA ACQUISITION; MOLECULAR STRUCTURE; TOMOGRAPHY;

EID: 0041971140     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.480113     Document Type: Conference Paper
Times cited : (4)

References (15)
  • 1
    • 0020658505 scopus 로고
    • Coherent scatter in diagnostic radiology
    • P. C. Johns and M. J. Yaffee, "Coherent scatter in diagnostic radiology," Med.Phys. 10, pp. 40-50, 1983.
    • (1983) Med. Phys. , vol.10 , pp. 40-50
    • Johns, P.C.1    Yaffee, M.J.2
  • 3
    • 0023493560 scopus 로고
    • X-ray diffraction computed tomography
    • G. Harding, J. Kosanetzky, and U. Neitzel, "X-ray diffraction computed tomography," Med.Phys. 14, pp. 515-532, 1987.
    • (1987) Med. Phys. , vol.14 , pp. 515-532
    • Harding, G.1    Kosanetzky, J.2    Neitzel, U.3
  • 4
    • 0023358685 scopus 로고
    • X-ray diffraction measurements of some plastic materials and body tissues
    • J. Kosanetzky, B. Knoerr, G. Harding, and U. Neitzel, "X-ray diffraction measurements of some plastic materials and body tissues," Med.Phys. 14 (4), pp. 526-532, 1987.
    • (1987) Med. Phys. , vol.14 , Issue.4 , pp. 526-532
    • Kosanetzky, J.1    Knoerr, B.2    Harding, G.3    Neitzel, U.4
  • 5
    • 0026085821 scopus 로고
    • Measurement of small-angle photon scattering from some breast tissues and tissue substitute materials
    • S. H. Evans, D. A. Bradley, D. R. Dance, J. E. Bateman, and C. H. Jones, "Measurement of small-angle photon scattering from some breast tissues and tissue substitute materials," Phys.Med.Biol. 36, pp. 7-18, 1991.
    • (1991) Phys. Med. Biol. , vol.36 , pp. 7-18
    • Evans, S.H.1    Bradley, D.A.2    Dance, D.R.3    Bateman, J.E.4    Jones, C.H.5
  • 6
    • 0029837665 scopus 로고    scopus 로고
    • Scattering of 60 kev photons by biological material and influence in diagnostic radiology
    • S. D. de Magalhães, O. D. Gonçalves, P. Rizzo, and J. Eichler, "Scattering of 60 kev photons by biological material and influence in diagnostic radiology," Med.Phys. 23, pp. 1635-1642, 1996.
    • (1996) Med. Phys. , vol.23 , pp. 1635-1642
    • De Magalhães, S.D.1    Gonçalves, O.D.2    Rizzo, P.3    Eichler, J.4
  • 7
    • 0031470131 scopus 로고    scopus 로고
    • Molecular differential cross sections for x-ray coherent scattering in fat and polymethyl methacrylate
    • A. Tartari, E. Casnati, C. Bonifazzi, and C. Baraldi, "Molecular differential cross sections for x-ray coherent scattering in fat and polymethyl methacrylate," Phys.Med.Biol. 42, pp. 2551-2560, 1997.
    • (1997) Phys. Med. Biol. , vol.42 , pp. 2551-2560
    • Tartari, A.1    Casnati, E.2    Bonifazzi, C.3    Baraldi, C.4
  • 8
    • 0031716007 scopus 로고    scopus 로고
    • Measured molecular coherent scattering form factors of animal tissues, plastics and human breast tissue
    • D. E. Peplow and K. Verghese, "Measured molecular coherent scattering form factors of animal tissues, plastics and human breast tissue," Phys.Med.Biol. 43, pp. 2431-2452, 1998.
    • (1998) Phys. Med. Biol. , vol.43 , pp. 2431-2452
    • Peplow, D.E.1    Verghese, K.2
  • 10
    • 0031665960 scopus 로고    scopus 로고
    • Feasibility study of x-ray diffraction computed tomography for medical imaging
    • U. Kleuker, P. Suortti, W. Weyrich, and P. Spanne, "Feasibility study of x-ray diffraction computed tomography for medical imaging," Phys.Med.Biol. 43, pp. 2911-2923, 1998.
    • (1998) Phys. Med. Biol. , vol.43 , pp. 2911-2923
    • Kleuker, U.1    Suortti, P.2    Weyrich, W.3    Spanne, P.4
  • 12
    • 0034466618 scopus 로고    scopus 로고
    • Novel concept for coherent scatter x-ray computed tomography in medical applications
    • J.-P. Schlomka, S. M. Schneider, and G. Harding, "Novel concept for coherent scatter x-ray computed tomography in medical applications," Proc. SPIE 4142, pp. 218-224, 2000.
    • (2000) Proc. SPIE , vol.4142 , pp. 218-224
    • Schlomka, J.-P.1    Schneider, S.M.2    Harding, G.3
  • 13
    • 0034875973 scopus 로고    scopus 로고
    • Coherent scatter computed tomography applying a fan-beam geometry
    • S. M. Schneider, J.-P. Schlomka, and G. Harding, "Coherent scatter computed tomography applying a fan-beam geometry," Proc. SPIE 4320, pp. 754-763, 2001.
    • (2001) Proc. SPIE , vol.4320 , pp. 754-763
    • Schneider, S.M.1    Schlomka, J.-P.2    Harding, G.3
  • 15
    • 0036980478 scopus 로고    scopus 로고
    • Simulations and experimental feasibility study of fan-beam coherent scatter ct
    • A. Harding, J.-P. Schlomka, and G. Harding, "Simulations and experimental feasibility study of fan-beam coherent scatter ct," Proc. SPIE 4786, pp. 202-209, 2002.
    • (2002) Proc. SPIE , vol.4786 , pp. 202-209
    • Harding, A.1    Schlomka, J.-P.2    Harding, G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.