1
-
-
0035121622
-
The results of internal fixation of three- and four-part proximal humeral fractures with the Polarus nail
-
A.O. Adedapo and J.O. Ikpeme, The results of internal fixation of three- and four-part proximal humeral fractures with the Polarus nail, Injury 32 (2001), 115-121.
-
(2001)
Injury
, vol.32
, pp. 115-121
-
-
Adedapo, A.O.1
Ikpeme, J.O.2
-
2
-
-
0043255289
-
Bio-mechanics of the upper limb
-
D. Dowson and V. Wright, eds, Mechanical Engineering Publications, London
-
A.A. Amis, Bio-mechanics of the upper limb, in: An Introduction to the Bio-Mechanics of Joints and Joint Replacement, D. Dowson and V. Wright, eds, Mechanical Engineering Publications, London, 1981, pp. 88-97.
-
(1981)
An Introduction to the Bio-Mechanics of Joints and Joint Replacement
, pp. 88-97
-
-
Amis, A.A.1
-
4
-
-
0033144878
-
Biomechanical comparison of bending and torsional properties in retrograde intramedullary nailing of humeral shaft fractures
-
J. Blum, H. Machemer, F. Baumgart, U. Schlegel, D. Wahl and P.M. Rommens, Biomechanical comparison of bending and torsional properties in retrograde intramedullary nailing of humeral shaft fractures, Journal Orthopaedic Trauma 13 (1999), 344-350.
-
(1999)
Journal Orthopaedic Trauma
, vol.13
, pp. 344-350
-
-
Blum, J.1
Machemer, H.2
Baumgart, F.3
Schlegel, U.4
Wahl, D.5
Rommens, P.M.6
-
5
-
-
0042754116
-
Element reference
-
ANSYS, Houston
-
Element reference, in: ANSYS 5.6 Documentation, ANSYS, Houston, 1999.
-
(1999)
ANSYS 5.6 Documentation
-
-
-
6
-
-
0029329150
-
A review of biomechanical studies of intramedullary nails
-
R.J. Eveleigh, A review of biomechanical studies of intramedullary nails, Medical Engineering & Physics 17 (1995), 323-331.
-
(1995)
Medical Engineering & Physics
, vol.17
, pp. 323-331
-
-
Eveleigh, R.J.1
-
7
-
-
0041752302
-
Materials for orthopaedic joint prostheses
-
D.F. Williams, ed., CRC Press, Florida
-
D.F. Gibbons, Materials for orthopaedic joint prostheses, in: Biocompatibility of Orthopaedic Implants, D.F. Williams, ed., CRC Press, Florida, 1982.
-
(1982)
Biocompatibility of Orthopaedic Implants
-
-
Gibbons, D.F.1
-
8
-
-
0042754132
-
Principles of fractures and dislocations
-
C.A. Rockwood, D.P. Green and R.W. Bucholz, eds, JB Lippincott Company, Philadelphia
-
J.W. Harkness and W.C. Ramsey, Principles of fractures and dislocations, in: Rockwood & Green's Fractures in Adults, C.A. Rockwood, D.P. Green and R.W. Bucholz, eds, JB Lippincott Company, Philadelphia, 1991, pp. 1-163.
-
(1991)
Rockwood & Green's Fractures in Adults
, pp. 1-163
-
-
Harkness, J.W.1
Ramsey, W.C.2
-
9
-
-
0028028185
-
Intramedullary interlocking nailing for humeral fractures: Experiences with the Russell-Taylor humeral nail
-
J.O. Ikpeme, Intramedullary interlocking nailing for humeral fractures: experiences with the Russell-Taylor humeral nail, Injury 25 (1994), 447-455.
-
(1994)
Injury
, vol.25
, pp. 447-455
-
-
Ikpeme, J.O.1
-
10
-
-
0024035190
-
The corrosion fatigue properties of surgical implants in a living body
-
M. Morita, T.S.H. Hayashi and Y. Tsukamoto, The corrosion fatigue properties of surgical implants in a living body, J. Biomed. Mater. Res. 22 (1998), 529-540.
-
(1998)
J. Biomed. Mater. Res.
, vol.22
, pp. 529-540
-
-
Morita, M.1
Hayashi, T.S.H.2
Tsukamoto, Y.3
-
11
-
-
0036372290
-
Measurement of the bony anatomy of the humerus using magnetic resonance imaging
-
A.H. Murdoch, K.J. Mathias and F.W. Smith, Measurement of the bony anatomy of the humerus using magnetic resonance imaging, Journal of Engineering in Medicine 216 (2002), 31-35.
-
(2002)
Journal of Engineering in Medicine
, vol.216
, pp. 31-35
-
-
Murdoch, A.H.1
Mathias, K.J.2
Smith, F.W.3
-
12
-
-
0028522652
-
Comparison of torsional strength of humeral intramedullary nailing: A cadaveric study
-
Schopfer, T.C. Hearn, L. Malisano, J.N. Powell and J.F. Kellam, Comparison of torsional strength of humeral intramedullary nailing: a cadaveric study, Journal Orthopaedic Trauma 8 (1994), 414-421.
-
(1994)
Journal Orthopaedic Trauma
, vol.8
, pp. 414-421
-
-
Schopfer, T.C.1
Hearn, L.2
Malisano, J.N.3
Powell4
Kellam, J.F.5
-
13
-
-
0024518018
-
Humeral locking nail: A preliminary report
-
H. Seidel, Humeral locking nail: a preliminary report, Orthopaedics 12 (1989), 219-226.
-
(1989)
Orthopaedics
, vol.12
, pp. 219-226
-
-
Seidel, H.1
-
14
-
-
0019417388
-
A new stainless steel alloy for surgical implants compared to 316 S12
-
E. Smethurst, A new stainless steel alloy for surgical implants compared to 316 S12, Biomaterials 2 (1981), 116-119.
-
(1981)
Biomaterials
, vol.2
, pp. 116-119
-
-
Smethurst, E.1
-
15
-
-
0031664672
-
Complications using the Seidel intramedullary humeral nail: Outcome in 31 patients
-
H. Svend-Hansen, M. Skettrup and M.W. Rathcke, Complications using the Seidel intramedullary humeral nail: outcome in 31 patients, Acta Orthopaedica Belgica 64 (1998), 291-295.
-
(1998)
Acta Orthopaedica Belgica
, vol.64
, pp. 291-295
-
-
Svend-Hansen, H.1
Skettrup, M.2
Rathcke, M.W.3
-
16
-
-
0028901393
-
The Seidel locking nail: The Nottingham experience
-
G.W. Varley, The Seidel locking nail: the Nottingham experience, Injury 26 (1995), 155-157.
-
(1995)
Injury
, vol.26
, pp. 155-157
-
-
Varley, G.W.1
-
17
-
-
0028315390
-
A biomechanicalanalysis of four humeral fracture fixation systems
-
M.C. Zimmerman, A.M. Waite, M. Deehan, J. Tovey and W. Oppenheim, A biomechanical analysis of four humeral fracture fixation systems, Journal Orthopaedic Trauma 8 (1994), 233-239.
-
(1994)
Journal Orthopaedic Trauma
, vol.8
, pp. 233-239
-
-
Zimmerman, M.C.1
Waite, A.M.2
Deehan, M.3
Tovey, J.4
Oppenheim, W.5
|