-
2
-
-
0020645013
-
Design and fabrication of the banded electrode array
-
Clark G.M., Shepherd R.K., Patrick J.F., Black R.C., Tong Y.C. Design and fabrication of the banded electrode array. Ann. N.Y. Acad. Sci. 405:1983;191-201.
-
(1983)
Ann. N.Y. Acad. Sci.
, vol.405
, pp. 191-201
-
-
Clark, G.M.1
Shepherd, R.K.2
Patrick, J.F.3
Black, R.C.4
Tong, Y.C.5
-
3
-
-
0029868754
-
Improved and simplified methods for specifying positions of the electrode bands of the cochlear implant array
-
Cohen L.T., Xu J., Xu S.A., Clark G.M. Improved and simplified methods for specifying positions of the electrode bands of the cochlear implant array. Am. J. Otol. 17:1996;859-865.
-
(1996)
Am. J. Otol.
, vol.17
, pp. 859-865
-
-
Cohen, L.T.1
Xu, J.2
Xu, S.A.3
Clark, G.M.4
-
4
-
-
0034054761
-
The Clarion electrode positioner: Temporal bone studies
-
Fayad J.N., Luxford W., Linthicum F.H. The Clarion electrode positioner: temporal bone studies. Am. J. Otol. 21:2000;226-229.
-
(2000)
Am. J. Otol.
, vol.21
, pp. 226-229
-
-
Fayad, J.N.1
Luxford, W.2
Linthicum, F.H.3
-
5
-
-
0028868915
-
Potential distributions and neural excitation patterns in a rotationally symmetric model of the electrically stimulated cochlea
-
Frijns J.H., de Snoo S.L., Schoonhoven R. Potential distributions and neural excitation patterns in a rotationally symmetric model of the electrically stimulated cochlea. Hear. Res. 87:1995;170-186.
-
(1995)
Hear. Res.
, vol.87
, pp. 170-186
-
-
Frijns, J.H.1
De Snoo, S.L.2
Schoonhoven, R.3
-
6
-
-
0025222018
-
Dimensions of the scala tympani in the human and cat with reference to cochlear implants
-
Hatsushika S., Shepherd R.K., Clark G.M., Tong Y.C., Funaska S. Dimensions of the scala tympani in the human and cat with reference to cochlear implants. Ann. Otol. Rhinol. Laryngol. 99:1990;871-876.
-
(1990)
Ann. Otol. Rhinol. Laryngol.
, vol.99
, pp. 871-876
-
-
Hatsushika, S.1
Shepherd, R.K.2
Clark, G.M.3
Tong, Y.C.4
Funaska, S.5
-
7
-
-
0036196393
-
Movements of cochlear implant electrodes inside the cochlea during insertion: An X-ray microscopy study
-
Hüttenbrink K.B., Zahnert T., Jolly C., Hofmann G. Movements of cochlear implant electrodes inside the cochlea during insertion: an X-ray microscopy study. Otol. Neurotol. 23:2002;187-191.
-
(2002)
Otol. Neurotol.
, vol.23
, pp. 187-191
-
-
Hüttenbrink, K.B.1
Zahnert, T.2
Jolly, C.3
Hofmann, G.4
-
8
-
-
0031851977
-
Spatial resolution of cochlear implants: The electrical field and excitation of auditory afferents
-
Kral A., Hartmann R., Mortazavi D., Klinke R. Spatial resolution of cochlear implants: the electrical field and excitation of auditory afferents. Hear. Res. 121:1998;11-28.
-
(1998)
Hear. Res.
, vol.121
, pp. 11-28
-
-
Kral, A.1
Hartmann, R.2
Mortazavi, D.3
Klinke, R.4
-
9
-
-
0027236682
-
Radiological evaluation of multichannel intracochlear implant insertion depth
-
Marsh M.A., Xu J., Blamey P.J., Whitford L.A., Xu S.A., Silverman J.M., et al. Radiological evaluation of multichannel intracochlear implant insertion depth. Am. J. Otol. 14:1993;386-391.
-
(1993)
Am. J. Otol.
, vol.14
, pp. 386-391
-
-
Marsh, M.A.1
Xu, J.2
Blamey, P.J.3
Whitford, L.A.4
Xu, S.A.5
Silverman, J.M.6
-
10
-
-
0030028143
-
A transparent model of the human scala tympani cavity
-
Rebscher S.J., Talbot N., Bruszewski W., Heilmann M., Brasell J., Merzenich M.M. A transparent model of the human scala tympani cavity. J. Neurosci. Methods. 64:1996;105-114.
-
(1996)
J. Neurosci. Methods
, vol.64
, pp. 105-114
-
-
Rebscher, S.J.1
Talbot, N.2
Bruszewski, W.3
Heilmann, M.4
Brasell, J.5
Merzenich, M.M.6
-
11
-
-
0033104647
-
Strategies to improve electrode positioning and safety in cochlear implants
-
Rebscher S.J., Heilmann M., Bruszewski W., Talbot N.H., Snyder R.L., Merzenich M.M. Strategies to improve electrode positioning and safety in cochlear implants. IEEE Trans. Biomed. Eng. 46:1999;340-352.
-
(1999)
IEEE Trans. Biomed. Eng.
, vol.46
, pp. 340-352
-
-
Rebscher, S.J.1
Heilmann, M.2
Bruszewski, W.3
Talbot, N.H.4
Snyder, R.L.5
Merzenich, M.M.6
-
12
-
-
0035039576
-
The effect of electrode configuration and duration of deafness on threshold and selectivity of response to intracochlear electrical stimulation
-
Rebscher S.J., Snyder R.L., Leak P.A. The effect of electrode configuration and duration of deafness on threshold and selectivity of response to intracochlear electrical stimulation. J. Acoust. Soc. Am. 109:2001;2035-2048.
-
(2001)
J. Acoust. Soc. Am.
, vol.109
, pp. 2035-2048
-
-
Rebscher, S.J.1
Snyder, R.L.2
Leak, P.A.3
-
13
-
-
0029087003
-
Precurved electrode array and insertion tool
-
Treaba C.G., Xu J., Xu S.A., Clark G.M. Precurved electrode array and insertion tool. Ann. Otol. Rhinol. Laryngol. 166:(Suppl):1994;438-441.
-
(1994)
Ann. Otol. Rhinol. Laryngol.
, vol.166
, Issue.SUPPL.
, pp. 438-441
-
-
Treaba, C.G.1
Xu, J.2
Xu, S.A.3
Clark, G.M.4
-
14
-
-
0019225849
-
Dimensions of the scala tympani in relation to the diameters of multichannel electrodes
-
Zrunek M., Lischka M., Hochmaier-Desoyer I., Burain K. Dimensions of the scala tympani in relation to the diameters of multichannel electrodes. Arch. Otorhinolaryngol. 229:1980;159-165.
-
(1980)
Arch. Otorhinolaryngol.
, vol.229
, pp. 159-165
-
-
Zrunek, M.1
Lischka, M.2
Hochmaier-Desoyer, I.3
Burain, K.4
|