메뉴 건너뛰기




Volumn 5030 I, Issue , 2003, Pages 349-360

Computer simulation of CT mammography using a flat-panel imager

Author keywords

CT; Flat panel detector; Mammography; Projection; Ray tracing; Reconstruction; Simulation

Indexed keywords

COMPUTER SIMULATION; COMPUTERIZED TOMOGRAPHY; DATA ACQUISITION; IMAGE RECONSTRUCTION; IMAGE SENSORS; PHOSPHORS; POISSON DISTRIBUTION; RADIATION DETECTORS; RAY TRACING; TRANSFER FUNCTIONS; X RAY RADIOGRAPHY;

EID: 0041875195     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.480015     Document Type: Conference Paper
Times cited : (51)

References (18)
  • 1
    • 0035999405 scopus 로고    scopus 로고
    • Cone-beam volume CT breast imaging: Feasibility study
    • B. Chen and R. Ning, "Cone-beam volume CT breast imaging: Feasibility study," Med. Phys. 29, pp. 755-770, 2002.
    • (2002) Med. Phys. , vol.29 , pp. 755-770
    • Chen, B.1    Ning, R.2
  • 2
    • 0035190741 scopus 로고    scopus 로고
    • Dedicated breast CT: Radiation dose and image quality evaluation
    • J. M. Boone, T. R. Nelson, K. K. Lindfors, and J. A. Seibert, "Dedicated breast CT: radiation dose and image quality evaluation," Radiology 221, pp. 657-667, 2001.
    • (2001) Radiology , vol.221 , pp. 657-667
    • Boone, J.M.1    Nelson, T.R.2    Lindfors, K.K.3    Seibert, J.A.4
  • 3
    • 0034860959 scopus 로고    scopus 로고
    • Flat-panel detector based cone beam volume CT breast imaging: Preliminary phantom study
    • R. Ning, B. Chen, D. Conover, L. McHugh, J. Cullinan, and R. Yu, "Flat-panel detector based cone beam volume CT breast imaging: preliminary phantom study," SPIE Proc. 4320, 2001.
    • (2001) SPIE Proc. , vol.4320
    • Ning, R.1    Chen, B.2    Conover, D.3    McHugh, L.4    Cullinan, J.5    Yu, R.6
  • 5
    • 0030657556 scopus 로고    scopus 로고
    • An accurate method for computer-generating tungsten anode x-ray spectra from 30 to 140 kv
    • J. M. Boone and J. A. Seibert, "An accurate method for computer-generating tungsten anode x-ray spectra from 30 to 140 kv," Med. Phys. 24, pp. 1661-1670, 1997.
    • (1997) Med. Phys. , vol.24 , pp. 1661-1670
    • Boone, J.M.1    Seibert, J.A.2
  • 6
    • 0032886446 scopus 로고    scopus 로고
    • Glandular breast dose for monoenergetic and high-energy x-ray beams: Monte carlo assessment
    • J. M. Boone, "Glandular breast dose for monoenergetic and high-energy x-ray beams: Monte carlo assessment," Radiology 213, pp. 23-37, 1999.
    • (1999) Radiology , vol.213 , pp. 23-37
    • Boone, J.M.1
  • 7
    • 0021952059 scopus 로고
    • Fast calculation of the exact radiological path for a three-dimensional CT array
    • R. L. Siddon, "Fast calculation of the exact radiological path for a three-dimensional CT array," Med. Phys. 12, pp. 252-255, 1985.
    • (1985) Med. Phys. , vol.12 , pp. 252-255
    • Siddon, R.L.1
  • 8
    • 0001780632 scopus 로고    scopus 로고
    • Statistical texture synthesis of mammographic images with clustered lumpy backgrounds
    • F. O. Bochud, C. K. Abbey, and M. P. Eckstein, "Statistical texture synthesis of mammographic images with clustered lumpy backgrounds," Opt Express 4, pp. 33-43, 1999.
    • (1999) Opt Express , vol.4 , pp. 33-43
    • Bochud, F.O.1    Abbey, C.K.2    Eckstein, M.P.3
  • 9
    • 0036734336 scopus 로고    scopus 로고
    • Mammogram synthesis using a 3d simulation, breast tissue model and image acquisition simulation
    • P. R. Bakic, M. Albert, D. Brzakovic, and A. D. A. Maidment, "Mammogram synthesis using a 3d simulation, breast tissue model and image acquisition simulation," Med. Phys. 29, pp. 2131-2139, 2002.
    • (2002) Med. Phys. , vol.29 , pp. 2131-2139
    • Bakic, P.R.1    Albert, M.2    Brzakovic, D.3    Maidment, A.D.A.4
  • 10
    • 0023196389 scopus 로고
    • X-ray characterization of normal and neoplastic breast tissues
    • P. C. Johns and M. J. Yaffe, "X-ray characterization of normal and neoplastic breast tissues," Phys. Med. Biol. 32, pp. 675-695, 1987.
    • (1987) Phys. Med. Biol. , vol.32 , pp. 675-695
    • Johns, P.C.1    Yaffe, M.J.2
  • 11
    • 0031019011 scopus 로고    scopus 로고
    • Empirical and theoretical investigation of the noise performance of indirect detection, active matrix flat-panel imagers (amfpis) for diagnostic radiology
    • J. H. Siewardsen, L. E. Antonuk, Y. El-Mohri, J. Yorkston, W. Huang, J. M. Boudry, and I. A. Cunningham, "Empirical and theoretical investigation of the noise performance of indirect detection, active matrix flat-panel imagers (amfpis) for diagnostic radiology," Med. Phys. 24, pp. 71-89, 1997.
    • (1997) Med. Phys. , vol.24 , pp. 71-89
    • Siewardsen, J.H.1    Antonuk, L.E.2    El-Mohri, Y.3    Yorkston, J.4    Huang, W.5    Boudry, J.M.6    Cunningham, I.A.7
  • 13
    • 81555223635 scopus 로고
    • A measurement of light yield of common inorganic scintillators
    • I. Holl, E. Lorenz, and G. Mageras, "A measurement of light yield of common inorganic scintillators," IEEE Trans. on Nuclear Science 35, pp. 105-109, 1988.
    • (1988) IEEE Trans. on Nuclear Science , vol.35 , pp. 105-109
    • Holl, I.1    Lorenz, E.2    Mageras, G.3
  • 15
    • 0036035340 scopus 로고    scopus 로고
    • Depth-dependent phosphor blur in indirect x-ray imaging sensors
    • A. Badano and R. Leimbach, "Depth-dependent phosphor blur in indirect x-ray imaging sensors," Proc SPIE 4682, pp. 94-106, 2002.
    • (2002) Proc SPIE , vol.4682 , pp. 94-106
    • Badano, A.1    Leimbach, R.2
  • 17
    • 0036032091 scopus 로고    scopus 로고
    • Signal statistics of x-ray computed tomography
    • B. Whiting, "Signal statistics of x-ray computed tomography," Proc SPIE 4682, pp. 53-60, 2002.
    • (2002) Proc SPIE , vol.4682 , pp. 53-60
    • Whiting, B.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.