메뉴 건너뛰기




Volumn 49, Issue 8, 2003, Pages 1245-1247

Hemoglobin variants and hemoglobin A1c analysis: Problem solved?

Author keywords

[No Author keywords available]

Indexed keywords

GLUCOSE; GLYCOSYLATED HEMOGLOBIN; HEMOGLOBIN; HEMOGLOBIN A1C;

EID: 0041866808     PISSN: 00099147     EISSN: None     Source Type: Journal    
DOI: 10.1373/49.8.1245     Document Type: Editorial
Times cited : (62)

References (18)
  • 1
    • 0036177713 scopus 로고    scopus 로고
    • Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus
    • Sacks DB, Bruns DE, Goldstein DE, Maclaren NK, McDonald JM, Parrott M. Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus. Clin Chem 2002;48:436-72.
    • (2002) Clin Chem , vol.48 , pp. 436-472
    • Sacks, D.B.1    Bruns, D.E.2    Goldstein, D.E.3    Maclaren, N.K.4    McDonald, J.M.5    Parrott, M.6
  • 2
    • 0003187466 scopus 로고    scopus 로고
    • Standards of medical care for patients with diabetes mellitus
    • American Diabetes Association. Standards of medical care for patients with diabetes mellitus. Diabetes Gare 2003;26(Suppl 1):S33-50.
    • (2003) Diabetes Gare , vol.26 , Issue.1 SUPPL.
  • 3
    • 0027370108 scopus 로고
    • The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus
    • The Diabetes Control and Complications Trial Research Group. The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus. N Engl J Med 1993;329:977-86.
    • (1993) N Engl J Med , vol.329 , pp. 977-986
  • 4
    • 0032511583 scopus 로고    scopus 로고
    • Intensive blood-glucose control with sulphonylureas or insulin compared with conventional treatment and risk of complications in patients with type 2 diabetes (UKPDS 33)
    • UK Prospective Diabetes Study (UKPDS) Group
    • Intensive blood-glucose control with sulphonylureas or insulin compared with conventional treatment and risk of complications in patients with type 2 diabetes (UKPDS 33). UK Prospective Diabetes Study (UKPDS) Group. Lancet 1998;352:837-53.
    • (1998) Lancet , vol.352 , pp. 837-853
  • 5
    • 0035134867 scopus 로고    scopus 로고
    • Effects of hemoglobin variants and chemically modified derivatives on assays for glycohemoglobin [Review]
    • Bry L, Chen PC, Sacks DB. Effects of hemoglobin variants and chemically modified derivatives on assays for glycohemoglobin [Review]. Clin Chem 2001;47:163-63.
    • (2001) Clin Chem , vol.47 , pp. 163-163
    • Bry, L.1    Chen, P.C.2    Sacks, D.B.3
  • 9
    • 0242585395 scopus 로고    scopus 로고
    • 1c measurement based on peptide analysis by electrospray ionization mass spectrometry with deuterium-labeled synthetic peptides as internal standards
    • 1c measurement based on peptide analysis by electrospray ionization mass spectrometry with deuterium-labeled synthetic peptides as internal standards. Clin Chem 2003;49:829-31.
    • (2003) Clin Chem , vol.49 , pp. 829-831
    • Nakanishi, T.1    Iguchi, K.2    Shimizu, H.3
  • 10
    • 0031031762 scopus 로고    scopus 로고
    • Grycated haemoglobin analysis
    • John WG. Grycated haemoglobin analysis [Review]. Ann Clin Biochem 1997;34(Pt 1):17-31.
    • (1997) Ann Clin Biochem , vol.34 , Issue.1 PART , pp. 17-31
    • John, W.G.1
  • 11
    • 0030910793 scopus 로고    scopus 로고
    • Electrospray mass spectrometry for measurement of glycohemoglobin
    • Miedema K. Electrospray mass spectrometry for measurement of glycohemoglobin [Editorial]. Clin Chem 1997;43:705-7.
    • (1997) Clin Chem , vol.43 , pp. 705-707
    • Miedema, K.1
  • 13
    • 0029971132 scopus 로고    scopus 로고
    • Interlaboratory variation of GHb assays in Victoria, Austraria
    • Gilbert RE, Goodall I, Young V, Jerums G. Interlaboratory variation of GHb assays in Victoria, Austraria. Diabetes Cate 1996;19:730-4.
    • (1996) Diabetes Cate , vol.19 , pp. 730-734
    • Gilbert, R.E.1    Goodall, I.2    Young, V.3    Jerums, G.4
  • 15
    • 0001213138 scopus 로고
    • Mass spectrometry in the characterization of variant hemoglobins
    • Desiderio DM, ed. New York: Plenum Publishing Corp.
    • Shackleton CHL, Witkowska HE. Mass spectrometry in the characterization of variant hemoglobins. In: Desiderio DM, ed. Mass spectrometry: clinical and biomedical applications. New York: Plenum Publishing Corp., 1994:135-99.
    • (1994) Mass Spectrometry: Clinical and Biomedical Applications , pp. 135-199
    • Shackleton, C.H.L.1    Witkowska, H.E.2
  • 17
    • 0027194807 scopus 로고
    • Influence of hemoglobin variants and derivatives on glycohemoglobin determinations, as investigated by 102 laboratories using 16 methods
    • Weykamp CW, Penders TJ, Muskiet FA, van der Slik W. Influence of hemoglobin variants and derivatives on glycohemoglobin determinations, as investigated by 102 laboratories using 16 methods. Clin Chem 1993;39:1717-23.
    • (1993) Clin Chem , vol.39 , pp. 1717-1723
    • Weykamp, C.W.1    Penders, T.J.2    Muskiet, F.A.3    Van Der Slik, W.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.