메뉴 건너뛰기




Volumn 36, Issue 3, 2003, Pages 216-222

Validity of esophageal pressure measurements with positive end-expiratory pressure in preterm infants

Author keywords

Dynamic lung mechanics; Esophageal pressure; Positive end expiratory pressure; Preterm infants

Indexed keywords

AIRWAY OBSTRUCTION; ANALYTICAL EQUIPMENT; ARTICLE; CATHETER; CLINICAL ARTICLE; COMPUTER PROGRAM; ENDOTRACHEAL INTUBATION; ESOPHAGUS PRESSURE; HUMAN; INFANT; LUNG DISEASE; LUNG MECHANICS; LUNG VOLUME; NONLINEAR SYSTEM; POSITIVE END EXPIRATORY PRESSURE; PREMATURITY; PRIORITY JOURNAL; THORAX PRESSURE;

EID: 0041854451     PISSN: 87556863     EISSN: None     Source Type: Journal    
DOI: 10.1002/ppul.10284     Document Type: Article
Times cited : (8)

References (13)
  • 4
    • 0022568093 scopus 로고
    • The accuracy of esophageal pressure measurements in convalescent and sick intubated infants
    • Heaf DP, Turner H, Stocks J, Helms P. The accuracy of esophageal pressure measurements in convalescent and sick intubated infants. Pediatr Pulmonol 1986;2:5-8.
    • (1986) Pediatr Pulmonol , vol.2 , pp. 5-8
    • Heaf, D.P.1    Turner, H.2    Stocks, J.3    Helms, P.4
  • 5
    • 0021089963 scopus 로고
    • Pulmonary compliance in sick low birthweight infants: How reliable is the measurement of oesophageal pressure?
    • Thomson A, Elliott J, Silverman M. Pulmonary compliance in sick low birthweight infants: how reliable is the measurement of oesophageal pressure? Arch Dis Child 1983;58:891-896.
    • (1983) Arch Dis Child , vol.58 , pp. 891-896
    • Thomson, A.1    Elliott, J.2    Silverman, M.3
  • 6
    • 0020508929 scopus 로고
    • Esophageal pressure in infants at elevated lung volumes and positive airway pressure
    • Beardsmore CS, Stocks J, Silverman M. Esophageal pressure in infants at elevated lung volumes and positive airway pressure. J Appl Physiol 1983;55:377-382.
    • (1983) J Appl Physiol , vol.55 , pp. 377-382
    • Beardsmore, C.S.1    Stocks, J.2    Silverman, M.3
  • 7
    • 0024443890 scopus 로고
    • Liquid-filled esophageal catheter for measuring pleural pressure in preterm neonates
    • Coates AL, Davis GM, Vallinis P, Outerbridge EW. Liquid-filled esophageal catheter for measuring pleural pressure in preterm neonates. J Appl Physiol 1989;67:889-893.
    • (1989) J Appl Physiol , vol.67 , pp. 889-893
    • Coates, A.L.1    Davis, G.M.2    Vallinis, P.3    Outerbridge, E.W.4
  • 8
    • 0014276251 scopus 로고
    • Estimation of nasotracheal tube length in neonates
    • Coldiron JS. Estimation of nasotracheal tube length in neonates. Pediatrics 1968;41:823.
    • (1968) Pediatrics , vol.41 , pp. 823
    • Coldiron, J.S.1
  • 9
    • 0024347757 scopus 로고
    • Infant lung function: Measurement conditions and equipment
    • Stocks J, Beardsmore C, Helms P. Infant lung function: measurement conditions and equipment. Eur Respir J 1989;2:123-129.
    • (1989) Eur Respir J , vol.2 , pp. 123-129
    • Stocks, J.1    Beardsmore, C.2    Helms, P.3
  • 10
    • 0001292451 scopus 로고
    • Physical properties of human lungs measured during spontaneous respiration
    • Mead J, Whittenberger JL. Physical properties of human lungs measured during spontaneous respiration. J Appl Physiol 1953;5:779-796.
    • (1953) J Appl Physiol , vol.5 , pp. 779-796
    • Mead, J.1    Whittenberger, J.L.2
  • 11
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;8476:307-310.
    • (1986) Lancet , vol.8476 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 12
    • 0017750438 scopus 로고
    • A new apparatus for the accurate measurement of airway resistance in infancy
    • Stocks J, Levy NM, Godfrey S. A new apparatus for the accurate measurement of airway resistance in infancy. J Appl Physiol 1977;43:155.
    • (1977) J Appl Physiol , vol.43 , pp. 155
    • Stocks, J.1    Levy, N.M.2    Godfrey, S.3
  • 13
    • 0042812583 scopus 로고
    • The effects of PEEP and unilateral lung disease on the measurement of esophageal pressure
    • Davis GM, Rubin SZ. The effects of PEEP and unilateral lung disease on the measurement of esophageal pressure. Am Rev Respir Dis 1993;147:130.
    • (1993) Am Rev Respir Dis , vol.147 , pp. 130
    • Davis, G.M.1    Rubin, S.Z.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.