1
-
-
76549154241
-
Transluminal treatment of atherosclerotic obstruction: Description of a new technique and a preliminary report of its application
-
Dotter C.T., Judkins M.P. Transluminal treatment of atherosclerotic obstruction: description of a new technique and a preliminary report of its application. Circulation. 30:1964;654-670.
-
(1964)
Circulation
, vol.30
, pp. 654-670
-
-
Dotter, C.T.1
Judkins, M.P.2
-
2
-
-
0018760094
-
Nonoperative dilatation of coronary artery stenosis. Percutaneous transluminal coronary angioplasty
-
Grüntzig A.R., Senning A., Siegenthaler W. Nonoperative dilatation of coronary artery stenosis. Percutaneous transluminal coronary angioplasty. N Engl J Med. 301:1979;61-68.
-
(1979)
N Engl J Med
, vol.301
, pp. 61-68
-
-
Grüntzig, A.R.1
Senning, A.2
Siegenthaler, W.3
-
3
-
-
0018874832
-
The mechanism of balloon angioplasty
-
Casteneda-Zunig W.R., Formanek A., Tadavarthy M., Vlodavar Z., Edwards J.E., Zollikofer C., Amplatz K. The mechanism of balloon angioplasty. Radiology. 135:1980;565-571.
-
(1980)
Radiology
, vol.135
, pp. 565-571
-
-
Casteneda-Zunig, W.R.1
Formanek, A.2
Tadavarthy, M.3
Vlodavar, Z.4
Edwards, J.E.5
Zollikofer, C.6
Amplatz, K.7
-
4
-
-
0020262837
-
Arterial disruption and remodeling following balloon dilatation
-
Zarins C.K., Lu C.T., Gewertz B.L., Lyon R.T., Rush D.S., Glagov S. Arterial disruption and remodeling following balloon dilatation. Surgery. 92:1982;1086-1095.
-
(1982)
Surgery
, vol.92
, pp. 1086-1095
-
-
Zarins, C.K.1
Lu, C.T.2
Gewertz, B.L.3
Lyon, R.T.4
Rush, D.S.5
Glagov, S.6
-
5
-
-
0042939750
-
Pathophysiologic bases for transluminal angioplasty
-
Chin A.K., Fogarty T.J., Kinney TBet al. Pathophysiologic bases for transluminal angioplasty. Surg Forum. 32:1981;323-325.
-
(1981)
Surg Forum
, vol.32
, pp. 323-325
-
-
Chin, A.K.1
Fogarty, T.J.2
Kinney, T.B.3
-
6
-
-
0021357562
-
A physical measurement of the mechanisms of transluminal angioplasty
-
Chin A.K., Kinney T.B., Rurik G.W., Shoor P.M., Fogarty T.J. A physical measurement of the mechanisms of transluminal angioplasty. Surgery. 95:1984;196-200.
-
(1984)
Surgery
, vol.95
, pp. 196-200
-
-
Chin, A.K.1
Kinney, T.B.2
Rurik, G.W.3
Shoor, P.M.4
Fogarty, T.J.5
-
7
-
-
0018873402
-
Evaluation of transluminal angioplasty of chronic coronary stenosis, value and limitations assessed in fresh human cadaver hearts
-
Lee G., Ikeda R.M., Joye J.A., Bogren H.G., DeMaria A.M., Mason D.T. Evaluation of transluminal angioplasty of chronic coronary stenosis, value and limitations assessed in fresh human cadaver hearts. Circulation. 61:1980;77-83.
-
(1980)
Circulation
, vol.61
, pp. 77-83
-
-
Lee, G.1
Ikeda, R.M.2
Joye, J.A.3
Bogren, H.G.4
DeMaria, A.M.5
Mason, D.T.6
-
8
-
-
0024393107
-
Restenosis after coronary angioplasty: Potential biologic determinants and role of intimal hyperplasia
-
Liu M.W., Roubin G.S., King S.B. Restenosis after coronary angioplasty: potential biologic determinants and role of intimal hyperplasia. Circulation. 79:1989;1374-1386.
-
(1989)
Circulation
, vol.79
, pp. 1374-1386
-
-
Liu, M.W.1
Roubin, G.S.2
King, S.B.3
-
9
-
-
38249000427
-
The reparative phenomena at the site of balloon angioplasty in humans and experimental models
-
Gravanis M.B., Robinson K., Santoian E.C., Schneider J., King S.B. The reparative phenomena at the site of balloon angioplasty in humans and experimental models. Cardiovasc Pathol. 2:1993;263-273.
-
(1993)
Cardiovasc Pathol
, vol.2
, pp. 263-273
-
-
Gravanis, M.B.1
Robinson, K.2
Santoian, E.C.3
Schneider, J.4
King, S.B.5
-
11
-
-
4243294051
-
Coronary artery balloon-catheter dilatation intraoperatively
-
A.J. Roberts, & C.R. Conti. J.B. Lippincott
-
Mills N.L., Solar R.J. Coronary artery balloon-catheter dilatation intraoperatively. Roberts A.J., Conti C.R. Current surgery of the heart. 1987;J.B. Lippincott.
-
(1987)
Current surgery of the heart
-
-
Mills, N.L.1
Solar, R.J.2
-
13
-
-
0023904401
-
Restenosis after successful coronary angioplasty. Pathophysiology and prevention
-
McBride W., Lange R.A., Hillis L.D. Restenosis after successful coronary angioplasty. Pathophysiology and prevention. N Engl J Med. 318:1988;1734-1737.
-
(1988)
N Engl J Med
, vol.318
, pp. 1734-1737
-
-
McBride, W.1
Lange, R.A.2
Hillis, L.D.3
-
14
-
-
0018874470
-
Transluminal angioplasty: Correlation of morphological and angiographic findings in an experimental model
-
Block P.C., Baughman K.L., Pasternack R.C., Fallon J.T. Transluminal angioplasty: correlation of morphological and angiographic findings in an experimental model. Circulation. 61:1980;778-785.
-
(1980)
Circulation
, vol.61
, pp. 778-785
-
-
Block, P.C.1
Baughman, K.L.2
Pasternack, R.C.3
Fallon, J.T.4
-
15
-
-
0019951763
-
Acute effects of transluminal angioplasty in three experimental models of atherosclerosis
-
Faxon D.P., Weber V.J., Haudenschild C.C., Gottsman S.B., McGovern W.A., Ryan T.J. Acute effects of transluminal angioplasty in three experimental models of atherosclerosis. Arteriosclerosis. 2:1982;125-133.
-
(1982)
Arteriosclerosis
, vol.2
, pp. 125-133
-
-
Faxon, D.P.1
Weber, V.J.2
Haudenschild, C.C.3
Gottsman, S.B.4
McGovern, W.A.5
Ryan, T.J.6
-
16
-
-
0021055358
-
The mechanism of transluminal angioplasty: Evidence for formation of aneurysms in experimental atherosclerosis
-
Sanborn T.A., Faxon D.P., Haudenschild C.C., Gottsman S.B., Ryan T.J. The mechanism of transluminal angioplasty: evidence for formation of aneurysms in experimental atherosclerosis. Circulation. 68:1983;1136-1140.
-
(1983)
Circulation
, vol.68
, pp. 1136-1140
-
-
Sanborn, T.A.1
Faxon, D.P.2
Haudenschild, C.C.3
Gottsman, S.B.4
Ryan, T.J.5
-
17
-
-
0021998408
-
Balloon angioplasty: Natural history of the pathophysiological response to injury in a pig model
-
Steele P.M., Chesebro J.H., Stanson A.W. Balloon angioplasty: natural history of the pathophysiological response to injury in a pig model. Circ Res. 57:1985;105-112.
-
(1985)
Circ Res
, vol.57
, pp. 105-112
-
-
Steele, P.M.1
Chesebro, J.H.2
Stanson, A.W.3
-
18
-
-
0023137097
-
Platelet accumulation in experimental angioplasty: Time course and relation to vascular damage
-
Wilentz J.R., Sanborn T.A., Haudenschild C.C., Valeri C.R., Ryan T.J., Faxon D.P. Platelet accumulation in experimental angioplasty: time course and relation to vascular damage. Circulation. 75:1987;636-642.
-
(1987)
Circulation
, vol.75
, pp. 636-642
-
-
Wilentz, J.R.1
Sanborn, T.A.2
Haudenschild, C.C.3
Valeri, C.R.4
Ryan, T.J.5
Faxon, D.P.6
-
19
-
-
0022346523
-
Coronary arterial findings after accidental death immediately after successful percutaneous coronary angioplasty
-
Soward A.L., Essed C.E., Serruys P.W. Coronary arterial findings after accidental death immediately after successful percutaneous coronary angioplasty. Am J Cardiol. 56:1985;794-795.
-
(1985)
Am J Cardiol
, vol.56
, pp. 794-795
-
-
Soward, A.L.1
Essed, C.E.2
Serruys, P.W.3
-
20
-
-
0023260361
-
Arterial changes after percutaneous coronary angioplasty: Results at autopsy
-
Kohchi K., Takebayashi S., Block P.C., Hirolki T., Nobuyoshi M. Arterial changes after percutaneous coronary angioplasty: results at autopsy. J Am Coll Cardiol. 10:1987;592-599.
-
(1987)
J Am Coll Cardiol
, vol.10
, pp. 592-599
-
-
Kohchi, K.1
Takebayashi, S.2
Block, P.C.3
Hirolki, T.4
Nobuyoshi, M.5
-
21
-
-
0042439002
-
Mechanically induced vascular smooth muscle cell contraction and cellular injury. Advances in bio-engineering
-
Barbee K., Thibault L. Mechanically induced vascular smooth muscle cell contraction and cellular injury. Advances in bio-engineering. ASME. 1991;28-31.
-
(1991)
ASME
, pp. 28-31
-
-
Barbee, K.1
Thibault, L.2
-
22
-
-
0028240007
-
Strain measurements in cultured vascular smooth muscle cell subjected to mechanical deformation
-
Barbee K., Macarak E., Thibault L. Strain measurements in cultured vascular smooth muscle cell subjected to mechanical deformation. Ann Biomed Eng. 22:1994;14-22.
-
(1994)
Ann Biomed Eng
, vol.22
, pp. 14-22
-
-
Barbee, K.1
Macarak, E.2
Thibault, L.3
-
23
-
-
0026722659
-
Coronary balloon angioplasty dissections: "The good, the bad and the ugly"
-
Waller B.F. Coronary balloon angioplasty dissections: "The good, the bad and the ugly" J Am Coll Cardiol. 20:1992;701-706.
-
(1992)
J Am Coll Cardiol
, vol.20
, pp. 701-706
-
-
Waller, B.F.1
-
24
-
-
0027458603
-
Progressive coronary dilatation: An angioplasty technique that creates controlled arterial injury and reduces complications
-
Banka V.S., Kochar G.S., Maniet A.R., Voci G. Progressive coronary dilatation: an angioplasty technique that creates controlled arterial injury and reduces complications. Am Heart J. 125:1993;61.
-
(1993)
Am Heart J
, vol.125
, pp. 61
-
-
Banka, V.S.1
Kochar, G.S.2
Maniet, A.R.3
Voci, G.4
-
25
-
-
0042439003
-
Minimally invasive angioplasty technique that minimizes arterial trauma and thus reduces complications
-
Shawl F. Minimally invasive angioplasty technique that minimizes arterial trauma and thus reduces complications. Catheter Cardiovasc Diagn. 29:1993;82.
-
(1993)
Catheter Cardiovasc Diagn
, vol.29
, pp. 82
-
-
Shawl, F.1
-
26
-
-
0027159041
-
Coronary angioplasty with gradual versus rapid balloon inflation: Initial results and complications
-
Ilia R., Cabin H., McConnell S., Cleman M., Remetz M. Coronary angioplasty with gradual versus rapid balloon inflation: initial results and complications. Catheter Cardiovasc Diagn. 29:1993;199-202.
-
(1993)
Catheter Cardiovasc Diagn
, vol.29
, pp. 199-202
-
-
Ilia, R.1
Cabin, H.2
McConnell, S.3
Cleman, M.4
Remetz, M.5
-
27
-
-
0028266292
-
A randomized comparison of the effects of gradual prolonged versus standard primary balloon inflation on early and late outcome. Results of a multicenter clinical trial
-
Ohman EMet al. A randomized comparison of the effects of gradual prolonged versus standard primary balloon inflation on early and late outcome. Results of a multicenter clinical trial. Circulation. 89:1994;1118-1125.
-
(1994)
Circulation
, vol.89
, pp. 1118-1125
-
-
Ohman, E.M.1
-
28
-
-
0026049106
-
Cutting balloon: A novel approach to percutaneous angioplasty
-
Barath P., Fishbein M.C., Vari S., Forrester J.S. Cutting balloon: a novel approach to percutaneous angioplasty. Am J Cardiol. 68:1991;1249-1252.
-
(1991)
Am J Cardiol
, vol.68
, pp. 1249-1252
-
-
Barath, P.1
Fishbein, M.C.2
Vari, S.3
Forrester, J.S.4
-
29
-
-
85059110196
-
Initial and six-month results of gradual and prolonged balloon angioplasty in small coronary arteries: A randomized comparison with cutting balloon angioplasty and conventional balloon angioplasty
-
Umeda H., Sawada Ket al. Initial and six-month results of gradual and prolonged balloon angioplasty in small coronary arteries: a randomized comparison with cutting balloon angioplasty and conventional balloon angioplasty. J Am Coll Cardiol. 39(Suppl A):2002;2A.
-
(2002)
J Am Coll Cardiol
, vol.39
, Issue.SUPPL. A
-
-
Umeda, H.1
Sawada, K.2
-
30
-
-
0027471917
-
Parallel angioplasty dilatation catheter and guide wire: A new technique for the dilatation of calcified coronary arteries
-
Yazdanfar S., Ledley G.S., Alfieri A., Strauss C., Kotler M.N. Parallel angioplasty dilatation catheter and guide wire: a new technique for the dilatation of calcified coronary arteries. Catheter Cardiovasc Diagn. 28:1993;72-75.
-
(1993)
Catheter Cardiovasc Diagn
, vol.28
, pp. 72-75
-
-
Yazdanfar, S.1
Ledley, G.S.2
Alfieri, A.3
Strauss, C.4
Kotler, M.N.5
-
31
-
-
0028233965
-
Longitudinal force focused coronary angioplasty: A technique for resistant lesions
-
Stillabower M.E. Longitudinal force focused coronary angioplasty: a technique for resistant lesions. Catheter Cardiovasc Diagn. 32:1994;196-198.
-
(1994)
Catheter Cardiovasc Diagn
, vol.32
, pp. 196-198
-
-
Stillabower, M.E.1
-
32
-
-
85059110423
-
Facilitated lumen enlargement by longitudinal force focused angioplasty
-
Khurana S., Bakalyar D., Schreiber T., Aimany S., Gangadharan V., Bowers T.R., Reddy V.M., O'Neill W.W. Facilitated lumen enlargement by longitudinal force focused angioplasty. J Invasive Cardiol. 7:1995;19A.
-
(1995)
J Invasive Cardiol
, vol.7
-
-
Khurana, S.1
Bakalyar, D.2
Schreiber, T.3
Aimany, S.4
Gangadharan, V.5
Bowers, T.R.6
Reddy, V.M.7
O'Neill, W.W.8
-
33
-
-
85031134736
-
Focused force coronary balloon angioplasty: Multicenter results with a novel balloon catheter device
-
Vandormael M., Ischinger T., Rieß; G., Antoni D., Den Heijer P., Dill H., Hoffmann M., Reifart N., Göhring S. Focused force coronary balloon angioplasty: multicenter results with a novel balloon catheter device. Germ J Cardiol. 84(4, Suppl 1):1995;228.
-
(1995)
Germ J Cardiol
, vol.84
, Issue.4 SUPPL. 1
, pp. 228
-
-
Vandormael, M.1
Ischinger, T.2
Rieß, G.3
Antoni, D.4
Den Heijer, P.5
Dill, H.6
Hoffmann, M.7
Reifart, N.8
Göhring, S.9
-
34
-
-
85059110352
-
Focused force coronary balloon angioplasty: Multicenter results with a novel balloon catheter device
-
Ischinger T., Vandormael M., Rieß G., Antoni D., Den Heijer P., Dill H., Krajcar M., Göhring S., Reifart N. Focused force coronary balloon angioplasty: multicenter results with a novel balloon catheter device. J Invasive Cardiol. 7(Suppl 1):1995;13C.
-
(1995)
J Invasive Cardiol
, vol.7
, Issue.SUPPL. 1
-
-
Ischinger, T.1
Vandormael, M.2
Rieß, G.3
Antoni, D.4
Den Heijer, P.5
Dill, H.6
Krajcar, M.7
Göhring, S.8
Reifart, N.9
-
35
-
-
0042939749
-
Technical realization and results of a new angioplasty balloon for application of increased focal stress
-
Solar R.J., Meany D.F., Miller R.T., Rahdert D.A., Radcliff M.B., Rieß G., Ischinger T.A. Technical realization and results of a new angioplasty balloon for application of increased focal stress. Germ J Cardiol. 84(4, Suppl 1):1995;227.
-
(1995)
Germ J Cardiol
, vol.84
, Issue.4 SUPPL. 1
, pp. 227
-
-
Solar, R.J.1
Meany, D.F.2
Miller, R.T.3
Rahdert, D.A.4
Radcliff, M.B.5
Rieß, G.6
Ischinger, T.A.7
-
36
-
-
85059110604
-
Use of a new focused force angioplasty device to facilitate low pressure PTCA
-
Solar R.J., Meany D.F., Miller R.T., Rahdert D.A., Radcliff M.B., Ischinger T.A. Use of a new focused force angioplasty device to facilitate low pressure PTCA. J Invasive Cardiol. 7(Suppl 1):1995;56C.
-
(1995)
J Invasive Cardiol
, vol.7
, Issue.SUPPL. 1
-
-
Solar, R.J.1
Meany, D.F.2
Miller, R.T.3
Rahdert, D.A.4
Radcliff, M.B.5
Ischinger, T.A.6
-
37
-
-
0041436630
-
Enhanced lumen enlargement with new focused force angioplasty device
-
Supplement
-
Solar R.J., Meany D.F., Miller R.T., Rahdert D.A., Radcliff M.B., Ischinger T.A. Enhanced lumen enlargement with new focused force angioplasty device. Circulation. 92(8):1995;I-147. Supplement.
-
(1995)
Circulation
, vol.92
, Issue.8
, pp. 147
-
-
Solar, R.J.1
Meany, D.F.2
Miller, R.T.3
Rahdert, D.A.4
Radcliff, M.B.5
Ischinger, T.A.6
-
38
-
-
0008935380
-
The pathology of various mechanical interventional procedures and devices
-
E.J. Topol. Philadelphia (PA): Saunders. Chap. 24
-
Waller B.F., Anderson P.G. The pathology of various mechanical interventional procedures and devices. Topol E.J. Textbook of interventional cardiology. 3rd ed:1999;447-465 Saunders, Philadelphia (PA). Chap. 24.
-
(1999)
Textbook of interventional cardiology 3rd ed
, pp. 447-465
-
-
Waller, B.F.1
Anderson, P.G.2
-
39
-
-
0041436629
-
Factors predicting restenosis after percutaneous coronary balloon angioplasty
-
Glazier J.J., Varricchione T.R., Ryan T.J., Ruocco N.A., Jacobs A.K., Faxon D.P. Factors predicting restenosis after percutaneous coronary balloon angioplasty. Am J Cardiol. 63:1989;905-920.
-
(1989)
Am J Cardiol
, vol.63
, pp. 905-920
-
-
Glazier, J.J.1
Varricchione, T.R.2
Ryan, T.J.3
Ruocco, N.A.4
Jacobs, A.K.5
Faxon, D.P.6
-
40
-
-
0023877183
-
Effects of percutaneous angioplasty on atherosclerotic plaques and relation of plaque composition and arterial size to outcome
-
Potkin B.N., Roberts W.C. Effects of percutaneous angioplasty on atherosclerotic plaques and relation of plaque composition and arterial size to outcome. Am J Cardiol. 62:1988;41-50.
-
(1988)
Am J Cardiol
, vol.62
, pp. 41-50
-
-
Potkin, B.N.1
Roberts, W.C.2
-
41
-
-
0026446395
-
Arterial responses to balloon coronary angioplasty: An intravascular ultrasound study
-
Potkin B.N., Keren G., Mintz G.S., Douek P.C., Pichard A.D., Satler L.F., Kent K.M., Leon M.B. Arterial responses to balloon coronary angioplasty: an intravascular ultrasound study. J Am Coll Cardiol. 20:1992;942-951.
-
(1992)
J Am Coll Cardiol
, vol.20
, pp. 942-951
-
-
Potkin, B.N.1
Keren, G.2
Mintz, G.S.3
Douek, P.C.4
Pichard, A.D.5
Satler, L.F.6
Kent, K.M.7
Leon, M.B.8
-
42
-
-
85031135635
-
Finite element analysis of balloon angioplasty: Mechanism of plaque expansion
-
Feb. 1-4
-
Miller RT, Rahdert DA, Radcliff MB, Solar RJ, Meany DF. Finite element analysis of balloon angioplasty: mechanism of plaque expansion. AHA Scientific Conference on the Functional and Structural Aspects of the Vascular Wall, Feb. 1-4, 1995.
-
(1995)
AHA Scientific Conference on the Functional and Structural Aspects of the Vascular Wall
-
-
Miller, R.T.1
Rahdert, D.A.2
Radcliff, M.B.3
Solar, R.J.4
Meany, D.F.5
-
43
-
-
0028370884
-
Static circumferential tangential modulus of human atherosclerotic tissue
-
Loree H.M., Grodzinsky A.J., Park S.Y., Gibson L.J., Lee R.T. Static circumferential tangential modulus of human atherosclerotic tissue. J Biomech. 27:1994;195-204.
-
(1994)
J Biomech
, vol.27
, pp. 195-204
-
-
Loree, H.M.1
Grodzinsky, A.J.2
Park, S.Y.3
Gibson, L.J.4
Lee, R.T.5
-
44
-
-
0027232022
-
Resistance of atherosclerotic plaque during coronary angioplasty
-
Chenu P., Zakhia R., Marchandise B., Jamart J., Michel X., Schroeder E. Resistance of atherosclerotic plaque during coronary angioplasty. Catheter Cardiovasc Diagn. 29:1993;203-209.
-
(1993)
Catheter Cardiovasc Diagn
, vol.29
, pp. 203-209
-
-
Chenu, P.1
Zakhia, R.2
Marchandise, B.3
Jamart, J.4
Michel, X.5
Schroeder, E.6
-
45
-
-
0026324496
-
Relation of stenosis resolution pressure to long term clinical outcome after successful percutaneous transluminal coronary angioplasty
-
Bottner R.K., Green C.E., Ewels C.J., Kent K.M. Relation of stenosis resolution pressure to long term clinical outcome after successful percutaneous transluminal coronary angioplasty. Am J Cardiol. 67:1991;953-956.
-
(1991)
Am J Cardiol
, vol.67
, pp. 953-956
-
-
Bottner, R.K.1
Green, C.E.2
Ewels, C.J.3
Kent, K.M.4
-
46
-
-
0041865223
-
Improved outcome with novel device for low pressure PTCA in de novo and in-stent lesions
-
in press
-
Ischinger T., Solar R., Hitzke E. Improved outcome with novel device for low pressure PTCA in de novo and in-stent lesions. Cardiovasc Radiat Med. 2003;. in press.
-
(2003)
Cardiovasc Radiat Med
-
-
Ischinger, T.1
Solar, R.2
Hitzke, E.3
|