Distal radius plating options

Author keywords

Distal radius fractures; Dorsal plating; Fragment specific fixation; Implant; Volar plating

Indexed keywords

STAINLESS STEEL; TITANIUM;

EID: 0041766636     PISSN: 10419918     EISSN: None     Source Type: Journal    
DOI: 10.1097/00001433-200308000-00005     Document Type: Review
Times cited : (8)

References (14)
  • 1
    • 0030454626 scopus 로고    scopus 로고
    • Operative treatment of volar intra-articular fractures of the distal end of the radius
    • Jupiter JB, Fernandez DL, Choon-Lai T, et al.: Operative treatment of volar intra-articular fractures of the distal end of the radius. J Bone Joint Surg Am 1996, 78A:1817-1828.
    • (1996) J Bone Joint Surg Am , vol.78 A , pp. 1817-1828
    • Jupiter, J.B.1    Fernandez, D.L.2    Choon-Lai, T.3
  • 2
    • 0030928604 scopus 로고    scopus 로고
    • Prospective multicenter trial of a plate for dorsal fixation of distal radius fractures
    • Ring D, Jupiter JB, Brennwald J, et al.: Prospective multicenter trial of a plate for dorsal fixation of distal radius fractures. J Hand Surg [Am] 1997, 22:777-784.
    • (1997) J Hand Surg [Am] , vol.22 , pp. 777-784
    • Ring, D.1    Jupiter, J.B.2    Brennwald, J.3
  • 3
    • 0034536828 scopus 로고    scopus 로고
    • Open reduction and internal fixation of the intra articular and unstable fractures of the distal radius using the AO distal radius plate
    • Campbell DA: Open reduction and internal fixation of the intra articular and unstable fractures of the distal radius using the AO distal radius plate. J Hand Surg [Br] 2000, 25B:528-534.
    • (2000) J Hand Surg [Br] , vol.25 B , pp. 528-534
    • Campbell, D.A.1
  • 4
    • 0036068485 scopus 로고    scopus 로고
    • Failure of a retinacular flap to prevent dorsal wrist pain after titanium Pi plate fixation of distal radius fractures
    • Chaing PP, Roach S, Baratz ME: Failure of a retinacular flap to prevent dorsal wrist pain after titanium Pi plate fixation of distal radius fractures. J Hand Surg [Am] 2002, 27A:724-728. The authors report no significant decrease in tendon irritation with dorsal plating of the distal radius despite using a retinacular flap to cover the Pi plate.
    • (2002) J Hand Surg [Am] , vol.27 A , pp. 724-728
    • Chaing, P.P.1    Roach, S.2    Baratz, M.E.3
  • 5
    • 0034237171 scopus 로고    scopus 로고
    • Initial experience with the Forte plate for dorsally displaced distal radius fractures
    • Finsen V, Aasheim T: Initial experience with the Forte plate for dorsally displaced distal radius fractures. Injury Int J Care Injured 2000, 31:445-448.
    • (2000) Injury Int J Care Injured , vol.31 , pp. 445-448
    • Finsen, V.1    Aasheim, T.2
  • 6
    • 0030010872 scopus 로고    scopus 로고
    • Fractures of the distal end of the radius treated by internal fixation and early function: A preliminary report of 20 cases
    • Rikli DA, Regazzoni P: Fractures of the distal end of the radius treated by internal fixation and early function: a preliminary report of 20 cases. J Bone Joint Surg Br 1996, 78B:588-592.
    • (1996) J Bone Joint Surg Br , vol.78 B , pp. 588-592
    • Rikli, D.A.1    Regazzoni, P.2
  • 7
    • 0033976014 scopus 로고    scopus 로고
    • Comparison of three different plating techniques for the dorsum of the distal radius: A biomechanical study
    • Peine R, Rikli DA, Hoffman R, et al.: Comparison of three different plating techniques for the dorsum of the distal radius: a biomechanical study. J Hand Surg [Am] 2000, 25A:29-33.
    • (2000) J Hand Surg [Am] , vol.25 A , pp. 29-33
    • Peine, R.1    Rikli, D.A.2    Hoffman, R.3
  • 8
    • 0034097721 scopus 로고    scopus 로고
    • Fractures of the distal radius treated by internal fixation and early function
    • Jakob M, Rikli DA, Regazzoni P: Fractures of the distal radius treated by internal fixation and early function. J Bone Joint Surg Br 2000, 82B:340-344.
    • (2000) J Bone Joint Surg Br , vol.82 B , pp. 340-344
    • Jakob, M.1    Rikli, D.A.2    Regazzoni, P.3
  • 9
    • 0032885140 scopus 로고    scopus 로고
    • Internal fixation of distal radius fractures with dorsal dislocation: Pi plate or two one-fourth tube plates? A prospective randomized study
    • Hahnloser D, Platz A, Amgwerd M, et al.: Internal fixation of distal radius fractures with dorsal dislocation: Pi plate or two one-fourth tube plates? A prospective randomized study. J Trauma 1999, 47:760-765.
    • (1999) J Trauma , vol.47 , pp. 760-765
    • Hahnloser, D.1    Platz, A.2    Amgwerd, M.3
  • 10
    • 0036749090 scopus 로고    scopus 로고
    • Open reduction and internal fixation of unstable distal radius fractures: Results using the TriMed fixation system
    • Konrath G, Bahler S: Open reduction and internal fixation of unstable distal radius fractures: results using the TriMed fixation system. J Orthop Trauma 2002, 16:578-585. The authors report good or excellent results in 23 of 25 patients treated prospectively with a fragment-specific fixation system.
    • (2002) J Orthop Trauma , vol.16 , pp. 578-585
    • Konrath, G.1    Bahler, S.2
  • 11
    • 0036241905 scopus 로고    scopus 로고
    • Palmer plating for dorsally displaced fractures of the distal radius
    • Kamano M, Honda Y, Kazuki K, et al.: Palmer plating for dorsally displaced fractures of the distal radius. Clin Orthop 2002, 397:403-408. The authors report complete bony union and no cases of tendon irritation in 33 of 33 patients treated with palmar plating for dorsally displaced distal radius fractures.
    • (2002) Clin Orthop , vol.397 , pp. 403-408
    • Kamano, M.1    Honda, Y.2    Kazuki, K.3
  • 12
    • 0036187811 scopus 로고    scopus 로고
    • Volar neutralization plate fixation of dorsally displaced distal radius fractures
    • Constatine KJ, Clawson MC, Stern PJ: Volar neutralization plate fixation of dorsally displaced distal radius fractures. Orthopedics 2002, 25:125-128. The authors report retrospectively 20 patients treated with velar application of an AOT plate with locking screws. Patients had 80% good or excellent results, with no loss of reduction, and only one case of dorsal tendon irritation from a proud screw.
    • (2002) Orthopedics , vol.25 , pp. 125-128
    • Constatine, K.J.1    Clawson, M.C.2    Stern, P.J.3
  • 13
    • 0037244095 scopus 로고    scopus 로고
    • Comparison of different distal radius dorsal and volar fracture fixation plates: A biomechanical study
    • Osada D, Viegas SF, Shah MA, et al.: Comparison of different distal radius dorsal and volar fracture fixation plates: a biomechanical study. J Hand Surg [Am] 2003, 28A:94-104. In this biomechanical cadaveric study, the authors found the SCS/V Avanta velar plate to be biomechanically superior to other modes of velar or dorsal plating.
    • (2003) J Hand Surg [Am] , vol.28 A , pp. 94-104
    • Osada, D.1    Viegas, S.F.2    Shah, M.A.3
  • 14
    • 0036130725 scopus 로고    scopus 로고
    • Volar fixation for dorsally displaced fractures of the distal radius: A preliminary report
    • Orbay JL, Fernandez DL: Volar fixation for dorsally displaced fractures of the distal radius: a preliminary report. J Hand Surg [Am] 2002, 27A:205-215. The authors report 31 of 31 good or excellent results with a velar plating technique for dorsally displaced fractures. They recommend this method as a stable form of fixation, with preservation of the dorsal soft tissues, rapid fracture healing, reduced need for bone grafting, and infrequent tendon problems.
    • (2002) J Hand Surg [Am] , vol.27 A , pp. 205-215
    • Orbay, J.L.1    Fernandez, D.L.2