메뉴 건너뛰기




Volumn 190, Issue 3, 2003, Pages 206-213

Pharmacokinetics of ethylene in man by on-line laser photoacoustic detection

Author keywords

Breath; Closed chamber technique; Ethene; Ethylene; Free radicals; Human; Lipid peroxidation; Pharmacokinetics; Photoacoustic spectroscopy

Indexed keywords

ETHYLENE;

EID: 0041592433     PISSN: 0041008X     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0041-008X(03)00164-9     Document Type: Article
Times cited : (18)

References (22)
  • 2
    • 0000023288 scopus 로고    scopus 로고
    • Geometrical optimization of a longitudinal resonant photoacoustic cell for sensitive and fast trace gas detection
    • Bijnen F., Reuss J., Harren F. Geometrical optimization of a longitudinal resonant photoacoustic cell for sensitive and fast trace gas detection. Rev. Sci. Instrum. 67:1996;2914-2923.
    • (1996) Rev. Sci. Instrum. , vol.67 , pp. 2914-2923
    • Bijnen, F.1    Reuss, J.2    Harren, F.3
  • 4
    • 0343133887 scopus 로고    scopus 로고
    • A physiological toxicokinetic model for exogenous and endogenous ethylene and ethylene oxide in rat, mouse and human: Formation of 2-hydroxyethyl adducts with hemoglobin and DNA
    • Csanády G., Denk B., Pütz C., Kreuzer P., Kessler W., Baur C., Gargas M., Filser J. A physiological toxicokinetic model for exogenous and endogenous ethylene and ethylene oxide in rat, mouse and human formation of 2-hydroxyethyl adducts with hemoglobin and DNA . Toxicol. Appl. Pharmacol. 165:2000;1-23.
    • (2000) Toxicol. Appl. Pharmacol. , vol.165 , pp. 1-23
    • Csanády, G.1    Denk, B.2    Pütz, C.3    Kreuzer, P.4    Kessler, W.5    Baur, C.6    Gargas, M.7    Filser, J.8
  • 6
    • 0029929592 scopus 로고    scopus 로고
    • Estimation of peroxidative damage: A critical review
    • Esterbauer H. Estimation of peroxidative damage a critical review . Pathol. Biol. 44:1996;25-28.
    • (1996) Pathol. Biol. , vol.44 , pp. 25-28
    • Esterbauer, H.1
  • 7
    • 0026792779 scopus 로고
    • The closed chamber technique uptake, endogenous production, excretion, steady-state kinetics and rates of metabolism of gases and vapors
    • Filser J. The closed chamber technique uptake, endogenous production, excretion, steady-state kinetics and rates of metabolism of gases and vapors. Arch. Toxicol. 66:1992;1-10.
    • (1992) Arch. Toxicol. , vol.66 , pp. 1-10
    • Filser, J.1
  • 8
    • 0026593234 scopus 로고
    • Phar- macokinetics of ethylene in man and body burden with ethylene oxide and hydroxylethylation of hemoglobin due to endogenous and environmental ethylene
    • Filser J., Denk B., Törnqvist M., Kessler W., Ehrenberg L. Phar- macokinetics of ethylene in man and body burden with ethylene oxide and hydroxylethylation of hemoglobin due to endogenous and environmental ethylene. Arch. Toxicol. 66:1992;157-163.
    • (1992) Arch. Toxicol. , vol.66 , pp. 157-163
    • Filser, J.1    Denk, B.2    Törnqvist, M.3    Kessler, W.4    Ehrenberg, L.5
  • 12
  • 13
    • 0026608832 scopus 로고
    • Experimental data from closed chamber gas uptake studies in rodents suggest lower uptake rate of chemical than calculated from literature values on alveolar ventilation
    • Johanson G., Filser J. Experimental data from closed chamber gas uptake studies in rodents suggest lower uptake rate of chemical than calculated from literature values on alveolar ventilation. Arch. Toxicol. 66:1992;291-295.
    • (1992) Arch. Toxicol. , vol.66 , pp. 291-295
    • Johanson, G.1    Filser, J.2
  • 14
    • 0030605035 scopus 로고    scopus 로고
    • PBPK model for butadiene metabolism to expoxides: Quantitative species differences in metabolism
    • Johanson G., Filser J. PBPK model for butadiene metabolism to expoxides quantitative species differences in metabolism . Toxicology. 113:1996;40-47.
    • (1996) Toxicology , vol.113 , pp. 40-47
    • Johanson, G.1    Filser, J.2
  • 16
    • 0025318667 scopus 로고
    • Generation of volatile hydrocarbons from amino acids and proteins by an iron/ascorbate/GSH system
    • Kessler W., Remmer H. Generation of volatile hydrocarbons from amino acids and proteins by an iron/ascorbate/GSH system. Biochem. Pharmacol. 39:1990;1347-1351.
    • (1990) Biochem. Pharmacol. , vol.39 , pp. 1347-1351
    • Kessler, W.1    Remmer, H.2
  • 17
    • 0028277936 scopus 로고
    • The potential of the hydrocarbon breath test as a measure of lipid peroxidation
    • Kneepkens C., Legage G., Roy C. The potential of the hydrocarbon breath test as a measure of lipid peroxidation. Free Radical Biol. Med. 17:1994;127-160.
    • (1994) Free Radical Biol. Med. , vol.17 , pp. 127-160
    • Kneepkens, C.1    Legage, G.2    Roy, C.3
  • 19
    • 0023662620 scopus 로고
    • Simplified calculation of body surface area
    • Mosteller R. Simplified calculation of body surface area. N. Engl. J. Med. 317:1987;1098.
    • (1987) N. Engl. J. Med. , vol.317 , pp. 1098
    • Mosteller, R.1
  • 20
    • 0015598584 scopus 로고
    • Solubility coefficients for inhaled anaesthetics for water, oil and biological media
    • Steward A., Allott P., Cowles A., Mapleson W.W., Setlow R. Solubility coefficients for inhaled anaesthetics for water, oil and biological media. Br. J. Anaesth. 45:1973;282.
    • (1973) Br. J. Anaesth. , vol.45 , pp. 282
    • Steward, A.1    Allott, P.2    Cowles, A.3    Mapleson, W.W.4    Setlow, R.5
  • 22
    • 0001019088 scopus 로고
    • Ethylene production and petiole growth in rumex plants induced by soil water logging: The application of a continuous flow system and a laser-driven intracavity photoacoustic detection system
    • Voesenek L., Harren F., Bögemann Blom, C., Reuss J. Ethylene production and petiole growth in rumex plants induced by soil water logging the application of a continuous flow system and a laser-driven intracavity photoacoustic detection system . Plant Physiol. 94:1990;1071-1077.
    • (1990) Plant Physiol. , vol.94 , pp. 1071-1077
    • Voesenek, L.1    Harren, F.2    Bögemann Blom, C.3    Reuss, J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.