메뉴 건너뛰기




Volumn 50, Issue 2, 2003, Pages 423-428

Novel interleaved spiral imaging motion correction technique using orbital navigators

Author keywords

Motion correction; Navigator echoes; Off resonance correction; Rigid body; Spiral

Indexed keywords

ELECTROMAGNETIC WAVE ATTENUATION; MOTION COMPENSATION; RIGID STRUCTURES; SPACE FLIGHT;

EID: 0041590983     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/mrm.10507     Document Type: Article
Times cited : (9)

References (19)
  • 2
    • 0028904705 scopus 로고
    • A velocity k-space analysis of flow effects in echo-planar and spiral imaging
    • Nishimura DG, Irarrazabal P, Meyer CH. A velocity k-space analysis of flow effects in echo-planar and spiral imaging. Magn Reson Med 1995;33:549-556.
    • (1995) Magn Reson Med , vol.33 , pp. 549-556
    • Nishimura, D.G.1    Irarrazabal, P.2    Meyer, C.H.3
  • 3
    • 0031003249 scopus 로고    scopus 로고
    • Reduction of motion artifacts in cine MRI using variable-density spiral trajectories
    • Liao JR, Pauly JM, Brosnan TJ, Pelc NJ. Reduction of motion artifacts in cine MRI using variable-density spiral trajectories. Magn Reson Med 1997;37:569-575.
    • (1997) Magn Reson Med , vol.37 , pp. 569-575
    • Liao, J.R.1    Pauly, J.M.2    Brosnan, T.J.3    Pelc, N.J.4
  • 7
    • 0033237785 scopus 로고    scopus 로고
    • Off-resonance correction of MR images
    • Schomberg H. Off-resonance correction of MR images. IEEE Trans Med Imaging 1999;18:481-495.
    • (1999) IEEE Trans Med Imaging , vol.18 , pp. 481-495
    • Schomberg, H.1
  • 8
    • 0028030441 scopus 로고
    • Analysis and correction of motion artifacts in diffusion weighted imaging
    • Anderson AW, Gore JC. Analysis and correction of motion artifacts in diffusion weighted imaging. Magn Reson Med 1994;32:379-387.
    • (1994) Magn Reson Med , vol.32 , pp. 379-387
    • Anderson, A.W.1    Gore, J.C.2
  • 10
    • 0031283439 scopus 로고    scopus 로고
    • Automatic correction of motion artifacts in magnetic resonance images using an entropy focus criterion
    • Atkinson D, Hill DL, Stoyle PN, Summers PE, Keevil SF. Automatic correction of motion artifacts in magnetic resonance images using an entropy focus criterion. IEEE Trans Med Imaging 1997;16:903-910.
    • (1997) IEEE Trans Med Imaging , vol.16 , pp. 903-910
    • Atkinson, D.1    Hill, D.L.2    Stoyle, P.N.3    Summers, P.E.4    Keevil, S.F.5
  • 11
    • 0032754594 scopus 로고    scopus 로고
    • Motion correction with PROPELLER MRI: Application to head motion and free-breathing cardiac imaging
    • Pipe JG. Motion correction with PROPELLER MRI: application to head motion and free-breathing cardiac imaging. Magn Reson Med 1999;42:963-969.
    • (1999) Magn Reson Med , vol.42 , pp. 963-969
    • Pipe, J.G.1
  • 12
    • 0035142510 scopus 로고    scopus 로고
    • Two-step navigatorless correction algorithm for radial k-space MRI acquisitions
    • Shankaranarayanan A, Wendt M, Lewin JS, Duerk JL. Two-step navigatorless correction algorithm for radial k-space MRI acquisitions. Magn Reson Med 2001;45:277-288.
    • (2001) Magn Reson Med , vol.45 , pp. 277-288
    • Shankaranarayanan, A.1    Wendt, M.2    Lewin, J.S.3    Duerk, J.L.4
  • 17
    • 0042846562 scopus 로고    scopus 로고
    • A simple method of gradient design due to local minor changes of a k-space trajectory using Bézier curves
    • Honolulu
    • Moriguchi H, Duerk JL. A simple method of gradient design due to local minor changes of a k-space trajectory using Bézier curves. In: Proceedings of the 10th Annual Meeting of ISMRM. Honolulu, 2002. p 824.
    • (2002) Proceedings of the 10th Annual Meeting of ISMRM , pp. 824
    • Moriguchi, H.1    Duerk, J.L.2
  • 18
    • 0035186327 scopus 로고    scopus 로고
    • Modified block uniform resampling (BURS) algorithm using truncated singular value decomposition: Fast accurate gridding with noise and artifact reduction
    • Moriguchi H, Duerk JL. Modified block uniform resampling (BURS) algorithm using truncated singular value decomposition: fast accurate gridding with noise and artifact reduction. Magn Reson Med 2001;46:1189-1201.
    • (2001) Magn Reson Med , vol.46 , pp. 1189-1201
    • Moriguchi, H.1    Duerk, J.L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.