메뉴 건너뛰기




Volumn 179, Issue 8, 2003, Pages 571-575

Improved patient repositioning accuracy by integrating an additional jaw fixation into a high precision face mask system in stereotactic radiotherapy of the head;Verbesserte lagerungsreproduzierbarkeit eines nichtinvasiven hochpräzisionsmaskensystems in der stereotaktischen radiotherapie durch eine integrierte kieferfixierung

Author keywords

Brain tumors; Digital imaging; Fractionated stereotactic radiotherapy; Head mask system; Noninvasive immobilization technique; Reproducibility

Indexed keywords

ARTICLE; CANCER RADIOTHERAPY; CLINICAL ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; FACE MASK; HEAD CANCER; HUMAN; IMMOBILIZATION; JAW; MANDIBLE; PATIENT POSITIONING; REPRODUCIBILITY; BODY POSTURE; BRAIN TUMOR; COMPARATIVE STUDY; COMPUTER ASSISTED DIAGNOSIS; COMPUTER ASSISTED RADIOTHERAPY; MASK; RADIATION DOSE; RADIATION DOSE FRACTIONATION; RADIOGRAPHY;

EID: 0041589597     PISSN: 01797158     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00066-003-0941-3     Document Type: Article
Times cited : (18)

References (16)
  • 1
    • 0035004921 scopus 로고    scopus 로고
    • Patient position reproducibility in stereotactically guided conformal radiotherapy using the Brain Lab mask system
    • Alheit H, Dornfeld S, Dawel M, Alheit M, Henzel B, Steckler K, Blank H, Geyer P. Patient position reproducibility in stereotactically guided conformal radiotherapy using the Brain Lab mask system. Strahlenther Onkol 2001;177:264-8.
    • (2001) Strahlenther Onkol , vol.177 , pp. 264-268
    • Alheit, H.1    Dornfeld, S.2    Dawel, M.3    Alheit, M.4    Henzel, B.5    Steckler, K.6    Blank, H.7    Geyer, P.8
  • 3
    • 0025907619 scopus 로고
    • A non-invasive, relocatable stereotactic frame for fractionated radiotherapy and multiple imaging
    • Graham JD, Wardngton AP, Gill S, Brada M. A non-invasive, relocatable stereotactic frame for fractionated radiotherapy and multiple imaging. Radiother Oncol 1991;21:60-2.
    • (1991) Radiother Oncol , vol.21 , pp. 60-62
    • Graham, J.D.1    Wardngton, A.P.2    Gill, S.3    Brada, M.4
  • 4
    • 0025134050 scopus 로고
    • A non-invasive method for fractionated stereotactic irradiation of brain tumors with linear accelerator
    • Hariz MI, Hednriksson R, Löfroth PO, Laitinen LV, Säterborg NE. A non-invasive method for fractionated stereotactic irradiation of brain tumors with linear accelerator. Radiother Oncol 1990;17:57-72.
    • (1990) Radiother Oncol , vol.17 , pp. 57-72
    • Hariz, M.I.1    Hednriksson, R.2    Löfroth, P.O.3    Laitinen, L.V.4    Säterborg, N.E.5
  • 5
    • 0028711672 scopus 로고
    • Quality assurance for non-invasive patient fixation during stereotactic convergent beam irradiation
    • Hodapp N, Nanko N, Rohner F, Frommhold H. Quality assurance for non-invasive patient fixation during stereotactic convergent beam irradiation. Acta Neurochir (Wien) 1994;62:Suppl:101-4.
    • (1994) Acta Neurochir (Wien) , vol.62
    • Hodapp, N.1    Nanko, N.2    Rohner, F.3    Frommhold, H.4
  • 6
    • 0027981561 scopus 로고
    • Adaptation and verification of the relocatable Gill-Thomas-Cosman frame in stereotactic radiotherapy
    • Kooy HM, Dunbar SF, Tarbell NJ. Adaptation and verification of the relocatable Gill-Thomas-Cosman frame in stereotactic radiotherapy. Int J Radiat Oncol Biol Phys 1994;30:685-91.
    • (1994) Int J Radiat Oncol Biol Phys , vol.30 , pp. 685-691
    • Kooy, H.M.1    Dunbar, S.F.2    Tarbell, N.J.3
  • 8
    • 0027490365 scopus 로고
    • Feasibility of patient immobilization for conventional cranial irradiation with a relocatable stereotactic frame
    • Laing RW, Thompson V, Wardngton AP, Brada M. Feasibility of patient immobilization for conventional cranial irradiation with a relocatable stereotactic frame. Br J Radiol 1993;66:1020-4.
    • (1993) Br J Radiol , vol.66 , pp. 1020-1024
    • Laing, R.W.1    Thompson, V.2    Wardngton, A.P.3    Brada, M.4
  • 9
    • 0024379031 scopus 로고
    • Stereotactic frame for neuroradiology and charged particle bragg peak radiosurgery of intracranial disorders
    • Lyman JT, Phillips MH, Frankel KA, Fabrikant JI. Stereotactic frame for neuroradiology and charged particle bragg peak radiosurgery of intracranial disorders. Int J Radiat Oncol Biol Phys 1989;16:1615-21.
    • (1989) Int J Radiat Oncol Biol Phys , vol.16 , pp. 1615-1621
    • Lyman, J.T.1    Phillips, M.H.2    Frankel, K.A.3    Fabrikant, J.I.4
  • 10
    • 0028999883 scopus 로고
    • A noninvasive thermoplastic head immobilization system. Technical note
    • Pilipuf MN, Goble JC, Kassell NF. A noninvasive thermoplastic head immobilization system. Technical note. J Neurosurg 1995;82:1082-5.
    • (1995) J Neurosurg , vol.82 , pp. 1082-1085
    • Pilipuf, M.N.1    Goble, J.C.2    Kassell, N.F.3
  • 11
    • 0028786274 scopus 로고
    • A precision cranial immobilization system for conformal stereotactic fractionated radiation therapy
    • Rosenthal SA, Gall KP, Jackson M, Thornton AF. A precision cranial immobilization system for conformal stereotactic fractionated radiation therapy. Int J Radiat Oncol Biol Phys 1995;33:1239-45.
    • (1995) Int J Radiat Oncol Biol Phys , vol.33 , pp. 1239-1245
    • Rosenthal, S.A.1    Gall, K.P.2    Jackson, M.3    Thornton, A.F.4
  • 12
    • 0043266323 scopus 로고
    • Lagerungsungenauigkeit eines individuellen maskensystems bei der hochpräzisionsbestrahlung von kopf-hals-tumoren: Bestimmung von abweichungen mittels stereotaktischer CT-koordinaten
    • Rudat V, Engenhardt R, Debus J, Wannenmacher M. Lagerungsungenauigkeit eines individuellen Maskensystems bei der Hochpräzisionsbestrahlung von Kopf-Hals-Tumoren: Bestimmung von Abweichungen mittels stereotaktischer CT-Koordinaten. Strahlenther Onkol 1995;171:Suppl 1:6.
    • (1995) Strahlenther Onkol , vol.171 , Issue.SUPPL. 1 , pp. 6
    • Rudat, V.1    Engenhardt, R.2    Debus, J.3    Wannenmacher, M.4
  • 14
    • 0031302413 scopus 로고    scopus 로고
    • Maskentechnik der firma Brain-LAB. Nichtinvasive fixierung bei stereotaktischen strahlentherapien
    • Stärk S, Grosu AL, Molls M, Kneschaurek P. Maskentechnik der Firma Brain-LAB. Nichtinvasive Fixierung bei stereotaktischen Strahlentherapien. Biomed Tech (Berl) Ergänzungsband 1997;42:352-3.
    • (1997) Biomed Tech (Berl) Ergänzungsband , vol.42 , pp. 352-353
    • Stärk, S.1    Grosu, A.L.2    Molls, M.3    Kneschaurek, P.4
  • 16
    • 0030752676 scopus 로고    scopus 로고
    • CT simulation in stereotactic brain radiotherapy - Analysis of isocenter reproducibility with mask fixation
    • Willner J, Flentje M, Bratengeier K. CT simulation in stereotactic brain radiotherapy - analysis of isocenter reproducibility with mask fixation. Radiother Oncol 1997;45:83-8.
    • (1997) Radiother Oncol , vol.45 , pp. 83-88
    • Willner, J.1    Flentje, M.2    Bratengeier, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.