메뉴 건너뛰기




Volumn 1, Issue , 2003, Pages 399-402

110 GHz broadband measurement of permittivity on human epidermis using 1 mm coaxial probe

Author keywords

[No Author keywords available]

Indexed keywords

BAND STRUCTURE; CELLS; MICROWAVES; PERMITTIVITY; TISSUE;

EID: 0041562469     PISSN: 0149645X     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (49)

References (7)
  • 3
    • 0019054932 scopus 로고
    • Coaxial line reflection methods for measuring dielectric properties of biological substances at radio and microwave frequencies- A review
    • M. A. Stuchly and S.S. Stuchly, "Coaxial line reflection methods for measuring dielectric properties of biological substances at radio and microwave frequencies- A review." IEEE Trans. Instrum. Meas., vol. IM-29, pp. 176-183, 1980
    • (1980) IEEE Trans. Instrum. Meas. , vol.IM-29 , pp. 176-183
    • Stuchly, M.A.1    Stuchly, S.S.2
  • 4
    • 0032190035 scopus 로고    scopus 로고
    • Variational formulation of open-ended coaxial line in contact with layered biological medium
    • Oct
    • E. Alanen, T. Lahtinen and J. Nuutinen, "Variational formulation of open-ended coaxial line in contact with layered biological medium." IEEE Tran.. Biomedical engineering, vol. 45, pp. 1241-1248, Oct 1998
    • (1998) IEEE Tran. Biomedical Engineering , vol.45 , pp. 1241-1248
    • Alanen, E.1    Lahtinen, T.2    Nuutinen, J.3
  • 5
    • 0035439652 scopus 로고    scopus 로고
    • A numerical study on the measurement region of an open-ended coaxial probe used for complex permittivity measurement
    • Sep
    • S. Hoshina, Y. kanai and M. miyakawa, "A numerical study on the measurement region of an open-ended coaxial probe used for complex permittivity measurement." IEEE Tran.. magnetics, vol. 37, pp. 3311-3314, Sep 2001
    • (2001) IEEE Tran. Magnetics , vol.37 , pp. 3311-3314
    • Hoshina, S.1    Kanai, Y.2    Miyakawa, M.3
  • 6
    • 0042481185 scopus 로고
    • Permittivity measurement using open-ended sensors and reference liquid calibration- An uncertainty analysis
    • Jan.
    • A. Nyshadham, C. L. Sibbald, and S.S. Stuchly, "Permittivity measurement using open-ended sensors and reference liquid calibration- An uncertainty analysis," IEEE Tran. Microwave Theory Tech., vol. 38, pp.8-14, Jan. 1990
    • (1990) IEEE Tran. Microwave Theory Tech. , vol.38 , pp. 8-14
    • Nyshadham, A.1    Sibbald, C.L.2    Stuchly, S.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.