Volumn 110, Issue 8, 2003, Pages 1551-1554

Repeatability of ocular blood flow pneumotonometry

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARTICLE; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; DIAGNOSTIC VALUE; EYE BLOOD FLOW; FEMALE; HUMAN; HUMAN EXPERIMENT; INTERMETHOD COMPARISON; INTRAOCULAR PRESSURE; NORMAL HUMAN; OCULOPLETHYSMOGRAPHY; PRESSURE MEASUREMENT; PRIORITY JOURNAL; REPRODUCIBILITY; STATISTICAL ANALYSIS;

EID: 0041528295     PISSN: 01616420     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0161-6420(03)00492-5     Document Type: Article
Times cited : (15)

References (10)
  • 1
    • 0025614886 scopus 로고
    • Tonometer utilization, accuracy and calibration under field conditions
    • Wessels IF, Oh Y. Tonometer utilization, accuracy and calibration under field conditions. Arch Ophthalmol 1990;108:1709-12.
    • (1990) Arch Ophthalmol , vol.108 , pp. 1709-1712
    • Wessels, I.F.1    Oh, Y.2
  • 2
    • 0031949697 scopus 로고    scopus 로고
    • Reproducibility of measurements with a new slit lamp-mounted ocular blood flow tonograph
    • Spraul CW, Lang GE, Ronzani M, et al. Reproducibility of measurements with a new slit lamp-mounted ocular blood flow tonograph. Graefes Arch Clin Exp Ophthalmol 1998;236:274-9.
    • (1998) Graefes Arch Clin Exp Ophthalmol , vol.236 , pp. 274-279
    • Spraul, C.W.1    Lang, G.E.2    Ronzani, M.3
  • 3
    • 0031721369 scopus 로고    scopus 로고
    • Clinical comparison of the ocular blood flow tonograph and the Goldmann applanation tonometer
    • Esgin H, Alimgil ML, Erda S. Clinical comparison of the ocular blood flow tonograph and the Goldmann applanation tonometer. Eur J Ophthalmol 1998;8:162-6.
    • (1998) Eur J Ophthalmol , vol.8 , pp. 162-166
    • Esgin, H.1    Alimgil, M.L.2    Erda, S.3
  • 4
    • 0032884749 scopus 로고    scopus 로고
    • Measuring agreement in method comparison studies
    • Bland JM, Altman DG. Measuring agreement in method comparison studies. Stat Methods Med Res 1999;8:135-60.
    • (1999) Stat Methods Med Res , vol.8 , pp. 135-160
    • Bland, J.M.1    Altman, D.G.2
  • 5
    • 0029781232 scopus 로고    scopus 로고
    • On the precision and reliability of IOP measurements
    • Gilchrist JM. On the precision and reliability of IOP measurements. Br J Ophthalmol 1996;80:586-7.
    • (1996) Br J Ophthalmol , vol.80 , pp. 586-587
    • Gilchrist, J.M.1
  • 6
    • 0028432917 scopus 로고
    • Validity of pulsatile ocular blood flow measurements
    • Silver DM, Farrell RA. Validity of pulsatile ocular blood flow measurements [review]. Surv Ophthalmol 1994;38:S72-8.
    • (1994) Surv Ophthalmol , vol.38
    • Silver, D.M.1    Farrell, R.A.2
  • 8
    • 0027251292 scopus 로고
    • Individual variability in the diurnal intraocular pressure curve
    • Wilensky JT, Gieser DK, Dietsche ML, et al. Individual variability in the diurnal intraocular pressure curve. Ophthalmology 1993;100:940-4.
    • (1993) Ophthalmology , vol.100 , pp. 940-944
    • Wilensky, J.T.1    Gieser, D.K.2    Dietsche, M.L.3
  • 9
    • 0015458332 scopus 로고
    • Effects of repeated tonometry: Genuine and sham measurements
    • Wilke K. Effects of repeated tonometry: genuine and sham measurements. Acta Ophthalmol (Copenh) 1972;50:574-82.
    • (1972) Acta Ophthalmol (Copenh) , vol.50 , pp. 574-582
    • Wilke, K.1
  • 10
    • 0033853806 scopus 로고    scopus 로고
    • Intraocular pressure and pulse rate measurements by the OBF tonograph-comparison to reference instruments
    • Yang YC, Illango B, Cook A, et al. Intraocular pressure and pulse rate measurements by the OBF tonograph-comparison to reference instruments. Ophthalmic Physiol Opt 2000;20:401-7.
    • (2000) Ophthalmic Physiol Opt , vol.20 , pp. 401-407
    • Yang, Y.C.1    Illango, B.2    Cook, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.