메뉴 건너뛰기




Volumn 43, Issue 8, 2003, Pages 1096-1106

Extracorporeal blood volume of donors during automated intermittent-flow plasmapheresis and its relevance to the prevention of circulatory reactions

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARTICLE; BLOOD DONOR; BLOOD TRANSFUSION REACTION; BLOOD VOLUME; CALCULATION; CARDIOVASCULAR RESPONSE; EXTRACORPOREAL CIRCULATION; FEMALE; GENDER; HEMATOCRIT; HUMAN; INTERMITTENT FLOW PLASMAPHERESIS; MALE; MATHEMATICAL MODEL; NORMAL HUMAN; PATIENT SELECTION; PLASMAPHERESIS; VALIDATION PROCESS;

EID: 0041428166     PISSN: 00411132     EISSN: None     Source Type: Journal    
DOI: 10.1046/j.1537-2995.2003.00455.x     Document Type: Article
Times cited : (9)

References (35)
  • 1
    • 0024596277 scopus 로고
    • Risks and safety practices in hemapheresis procedures
    • Huestis DW. Risks and safety practices in hemapheresis procedures. Arch Pathol Lab Med 1989;113:273-8.
    • (1989) Arch Pathol Lab Med , vol.113 , pp. 273-278
    • Huestis, D.W.1
  • 2
    • 0041820642 scopus 로고    scopus 로고
    • Code of federal regulations Title 21 CFR Part 640. Washington (DC): US Government Printing Office; 2001
    • Code of federal regulations Title 21 CFR Part 640. Washington (DC): US Government Printing Office; 2001.
  • 3
    • 0041820638 scopus 로고
    • Rockville (MD): CBER Office of Communication, Training, and Manufacturer's Assistance; Nov 14
    • Food and Drug Administration. Memorandum: volume limits for automated collection of source plasma. Rockville (MD): CBER Office of Communication, Training, and Manufacturer's Assistance; 1992 Nov 14.
    • (1992) Memorandum: Volume Limits for Automated Collection of Source Plasma
  • 6
    • 0041820641 scopus 로고
    • Recommendations for the execution of automated plasmapheresis for the collection of donor plasma
    • Standing Hemapheresis Commission of the German Society for Transfusion Medicine and Immunohematology. [Recommendations for the execution of automated plasmapheresis for the collection of donor plasma] (in German). Infusionsther Transfusionsmed 1994;21:349-54.
    • (1994) Infusionsther Transfusionsmed , vol.21 , pp. 349-354
  • 7
    • 0000213899 scopus 로고    scopus 로고
    • Directives for the procurement of blood and blood constituents and for the application of blood products (hemotherapy)
    • in German
    • Federal Physicians Chamber and Paul-Ehrlich-Institute (Federal Agency for Sera and Vaccines). [Directives for the procurement of blood and blood constituents and for the application of blood products (hemotherapy)] (in German). Bundesgesundheitsbl Gesundheitsforsch Gesundheitsschutz 2000;43:555-89.
    • (2000) Bundesgesundheitsbl Gesundheitsforsch Gesundheitsschutz , vol.43 , pp. 555-589
  • 12
    • 0005983659 scopus 로고    scopus 로고
    • Acute blood loss and burnings in surgery
    • Mueller-Eckhardt C, ed. Berlin: Springer-Verlag
    • Blauhut B, Lundsgaard-Hansen P. [Acute blood loss and burnings in surgery] (in German). In: Mueller-Eckhardt C, ed. Transfusionsmedizin. Vol. 2. Berlin: Springer-Verlag; 1996:291-320.
    • (1996) Transfusionsmedizin , vol.2 , pp. 291-320
    • Blauhut, B.1    Lundsgaard-Hansen, P.2
  • 15
    • 0032739615 scopus 로고    scopus 로고
    • Elaboration of reference values for blood volume determination methods with red cell labelling indicator dilution techniques using values from the literature
    • Lauermann I, Hecker H, Kirchner E. [Elaboration of reference values for blood volume determination methods with red cell labelling indicator dilution techniques using values from the literature] (English abstract). Infusionsther Transfusionsmed 1999;26:360-6.
    • (1999) Infusionsther Transfusionsmed , vol.26 , pp. 360-366
    • Lauermann, I.1    Hecker, H.2    Kirchner, E.3
  • 16
    • 0000719057 scopus 로고
    • Prediction of blood volume in normal human adults
    • Nadler SB, Hidalgo JU, Bloch T. Prediction of blood volume in normal human adults. Surgery 1962;51:224-32.
    • (1962) Surgery , vol.51 , pp. 224-232
    • Nadler, S.B.1    Hidalgo, J.U.2    Bloch, T.3
  • 18
    • 73649151893 scopus 로고
    • Red cell, plasma, and blood volume in healthy women measured by radiochromium-labeling and hematocrit
    • Brown E, Hopper J, Hodges L, et al. Red cell, plasma, and blood volume in healthy women measured by radiochromium-labeling and hematocrit. J Clin Invest 1962;41:2182-90.
    • (1962) J Clin Invest , vol.41 , pp. 2182-2190
    • Brown, E.1    Hopper, J.2    Hodges, L.3
  • 19
    • 0001517342 scopus 로고
    • Red cell, plasma, and blood volume in healthy men measured by radiochromium (Cr51) cell tagging and hematocrit: Influence of age, somatotype and habits of physical activity on the variance after regression of volumes to height and weight combined
    • Wennesland R, Brown E, Hopper J, et al. Red cell, plasma, and blood volume in healthy men measured by radiochromium (Cr51) cell tagging and hematocrit: influence of age, somatotype and habits of physical activity on the variance after regression of volumes to height and weight combined. J Clin Invest 1959;38:1065-77.
    • (1959) J Clin Invest , vol.38 , pp. 1065-1077
    • Wennesland, R.1    Brown, E.2    Hopper, J.3
  • 20
    • 0013619339 scopus 로고
    • Fluids and electrolytes in the acutely ill adult
    • Philadelphia: Saunders
    • Shoemaker WC. Fluids and electrolytes in the acutely ill adult. In: Shoemaker WC, Ayres S, Grenvik A, et al., eds. Textbook of critical care. Vol. 2. Philadelphia: Saunders; 1989:1130.
    • (1989) Textbook of Critical Care , vol.2 , pp. 1130
    • Shoemaker, W.C.1
  • 21
    • 33744839368 scopus 로고
    • Clinical calorimetry. X. A formula to estimate the approximate surface area if height and weight be known
    • DuBois D, DuBois EF. Clinical calorimetry. X. A formula to estimate the approximate surface area if height and weight be known. Arch Intern Med 1916;17:863-71.
    • (1916) Arch Intern Med , vol.17 , pp. 863-871
    • DuBois, D.1    DuBois, E.F.2
  • 22
    • 0023662620 scopus 로고
    • Simplified calculation of body-surface area
    • Mosteller RD. Simplified calculation of body-surface area. N Engl J Med 1987;317:1098.
    • (1987) N Engl J Med , vol.317 , pp. 1098
    • Mosteller, R.D.1
  • 23
    • 0014149484 scopus 로고
    • Plasma protein kinetics of the early transcapillary refill after hemorrhage in man
    • Skillman JJ, Awwad HK, Moore FD. Plasma protein kinetics of the early transcapillary refill after hemorrhage in man. Surg Gynecol Obstet 1967;125:983-96.
    • (1967) Surg Gynecol Obstet , vol.125 , pp. 983-996
    • Skillman, J.J.1    Awwad, H.K.2    Moore, F.D.3
  • 25
    • 0013563779 scopus 로고
    • Transcapillary refilling after hemorrhage in normal man: Basal rates and volumes, effect of norepinephrine
    • Lister J, McNeill IF, Marshall VC, et al. Transcapillary refilling after hemorrhage in normal man: basal rates and volumes, effect of norepinephrine. Ann Surg 1963;158:698-712.
    • (1963) Ann Surg , vol.158 , pp. 698-712
    • Lister, J.1    McNeill, I.F.2    Marshall, V.C.3
  • 26
    • 0013897227 scopus 로고
    • Hemorrhage in normal man. I. Distribution and dispersal of saline infusions following acute blood loss: Clinical kinetics of blood volume support
    • Moore FD, Dagher FJ, Boyden CM, et al. Hemorrhage in normal man. I. Distribution and dispersal of saline infusions following acute blood loss: clinical kinetics of blood volume support. Ann Surg 1966;163:485-504.
    • (1966) Ann Surg , vol.163 , pp. 485-504
    • Moore, F.D.1    Dagher, F.J.2    Boyden, C.M.3
  • 27
    • 0041319935 scopus 로고    scopus 로고
    • Blood volume is a bad predictor of the risk of hypovolemic reactions in plasmapheresis donors
    • Karger R, Junck H, Slonka J, et al. Blood volume is a bad predictor of the risk of hypovolemic reactions in plasmapheresis donors (abstract). Infus Ther Transfus Med 2002;29(Suppl 1):52.
    • (2002) Infus Ther Transfus Med , vol.29 , Issue.SUPPL. 1 , pp. 52
    • Karger, R.1    Junck, H.2    Slonka, J.3
  • 28
    • 0023137433 scopus 로고
    • Donor plasmapheresis: A comparative study using four different types of equipment
    • Perseghin P, Pagani A, Fornasari PM, et al. Donor plasmapheresis: a comparative study using four different types of equipment. Int J Artif Organs 1987;10:51-6.
    • (1987) Int J Artif Organs , vol.10 , pp. 51-56
    • Perseghin, P.1    Pagani, A.2    Fornasari, P.M.3
  • 29
  • 30
    • 0035683247 scopus 로고    scopus 로고
    • A study of 178 consecutive vasovagal syncopal reactions from the perspective of safety
    • Newman BH, Graves S. A study of 178 consecutive vasovagal syncopal reactions from the perspective of safety. Transfusion 2001;41:1475-9.
    • (2001) Transfusion , vol.41 , pp. 1475-1479
    • Newman, B.H.1    Graves, S.2
  • 31
    • 0042822646 scopus 로고    scopus 로고
    • Safety of plasmapheresis donors-analysis of donor reactions and technical problems in 40,000 plasmaphereses
    • Karger R, Slonka J, Junck H, et al. Safety of plasmapheresis donors-analysis of donor reactions and technical problems in 40,000 plasmaphereses (abstract). Infus Ther Transfus Med 2002;29(Suppl 1):29.
    • (2002) Infus Ther Transfus Med , vol.29 , Issue.SUPPL. 1 , pp. 29
    • Karger, R.1    Slonka, J.2    Junck, H.3
  • 32
    • 0036886533 scopus 로고    scopus 로고
    • Vasovagal reactions in high school students: Findings relative to race, risk factor synergism, female sex, and non-high school participants
    • Newman BH. Vasovagal reactions in high school students: findings relative to race, risk factor synergism, female sex, and non-high school participants. Transfusion 2002;42:1557-60.
    • (2002) Transfusion , vol.42 , pp. 1557-1560
    • Newman, B.H.1
  • 33
    • 0032966652 scopus 로고    scopus 로고
    • A case-controlled multicenter study of vasovagal reactions in blood donors: Influence of sex, age, donation status, weight, blood pressure, and pulse
    • Trouern-Trend JJ, Cable RG, Badon SJ, et al. A case-controlled multicenter study of vasovagal reactions in blood donors: influence of sex, age, donation status, weight, blood pressure, and pulse. Transfusion 1999;39:316-20.
    • (1999) Transfusion , vol.39 , pp. 316-320
    • Trouern-Trend, J.J.1    Cable, R.G.2    Badon, S.J.3
  • 35
    • 0019257610 scopus 로고
    • Vasovagal reactions in blood donors
    • Ogata H, Iinuma N, Nagashima K, et al. Vasovagal reactions in blood donors. Transfusion 1980;20:679-83.
    • (1980) Transfusion , vol.20 , pp. 679-683
    • Ogata, H.1    Iinuma, N.2    Nagashima, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.