메뉴 건너뛰기




Volumn 61, Issue 7, 2003, Pages 852-859

Eddy current sensor networks for aircraft fatigue monitoring

Author keywords

Cracks; Eddy current testing; Health monitoring; Imaging; Meandering winding magnetometer arrays

Indexed keywords

AIRCRAFT; CRACKS; FATIGUE OF MATERIALS; MAGNETOMETERS; SENSORS;

EID: 0041425279     PISSN: 00255327     EISSN: None     Source Type: Trade Journal    
DOI: None     Document Type: Article
Times cited : (41)

References (19)
  • 1
    • 0001193323 scopus 로고
    • Magnetometers for improved characterization in aerospace applications
    • Goldfine, N.J., "Magnetometers for Improved Characterization in Aerospace Applications," Materials Evaluation, Vol. 51, No. 3,1993, pp. 396-405.
    • (1993) Materials Evaluation , vol.51 , Issue.3 , pp. 396-405
    • Goldfine, N.J.1
  • 2
    • 0002886481 scopus 로고    scopus 로고
    • Early stage fatigue detection with application to widespread fatigue damage assessment in military and commercial aircraft
    • July
    • Goldfine, N.J., "Early Stage Fatigue Detection with Application to Widespread Fatigue Damage Assessment in Military and Commercial Aircraft," First DoD/FAA/NASA Conference on Aging Aircraft, July 1997.
    • (1997) First DoD/FAA/NASA Conference on Aging Aircraft
    • Goldfine, N.J.1
  • 5
    • 27144523599 scopus 로고    scopus 로고
    • Nondestructive evaluation for CBM and PHM of legacy and new platforms
    • Virginia Beach, Virginia, Society for Machinery Failure Prevention Technology, April
    • Goldfine, N. and V. Zilberstein, "Nondestructive Evaluation for CBM and PHM of Legacy and New Platforms," The 57th MFPT Conference, Virginia Beach, Virginia, Society for Machinery Failure Prevention Technology, April 2003.
    • (2003) The 57th MFPT Conference
    • Goldfine, N.1    Zilberstein, V.2
  • 11
    • 0042154649 scopus 로고    scopus 로고
    • MWM eddy current sensor array imaging of surface and hidden corrosion for improved fleet readiness and cost avoidance
    • Clear-water Beach, Florida, 11-13 February
    • Goldfine, N., V. Zilberstein and R. Murner, "MWM Eddy Current Sensor Array Imaging of Surface and Hidden Corrosion for Improved Fleet Readiness and Cost Avoidance," US Army Corrosion Conference, Clear-water Beach, Florida, 11-13 February 2003.
    • (2003) US Army Corrosion Conference
    • Goldfine, N.1    Zilberstein, V.2    Murner, R.3
  • 12
    • 0043156644 scopus 로고    scopus 로고
    • Application of the jentek 'MWM' sensor to full scale structural testing: A case history
    • San Francisco, California, September
    • Guadamuz, M., D.E. Pettit and D. VanOtterloo, "Application of the JENTEK 'MWM' Sensor to Full Scale Structural Testing: A Case History," Sixth Joint Conference on Aging Aircraft, San Francisco, California, September 2002.
    • (2002) Sixth Joint Conference on Aging Aircraft
    • Guadamuz, M.1    Pettit, D.E.2    Vanotterloo, D.3
  • 16
    • 0042154651 scopus 로고    scopus 로고
    • Validation of multi-frequency eddy current MWM sensors and MWM-arrays for coating production quality and refurbishment assessment
    • Atlanta, Georgia, ASME, June
    • Zilberstein, V, I. Shay, R. Lyons, N. Goldfine, T. Malow and R. Reiche, "Validation of Multi-frequency Eddy Current MWM Sensors and MWM-arrays for Coating Production Quality and Refurbishment Assessment," Turbo Expo Conference, Atlanta, Georgia, ASME, June 2003.
    • (2003) Turbo Expo Conference
    • Zilberstein, V.1    Shay, I.2    Lyons, R.3    Goldfine, N.4    Malow, T.5    Reiche, R.6
  • 19
    • 0035207008 scopus 로고    scopus 로고
    • MWM eddy current sensors for monitoring of crack initiation and growth during fatigue tests and in service
    • Zilberstein, V., D. Schlicker, K. Walrath, V. Weiss and N. Goldfine, "MWM Eddy Current Sensors for Monitoring of Crack Initiation and Growth during Fatigue Tests and in Service," International Journal of Fatigue, Vol. 23, 2001, pp. S477-S485.
    • (2001) International Journal of Fatigue , vol.23
    • Zilberstein, V.1    Schlicker, D.2    Walrath, K.3    Weiss, V.4    Goldfine, N.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.