-
1
-
-
0030227540
-
Ten-year evaluation of removable partial dentures: Survival rates based on retreatment, not wearing and replacement
-
Vermeulen A.H., Keltjens H.M., van't Hof M.A., Kayser A.F. Ten-year evaluation of removable partial dentures survival rates based on retreatment, not wearing and replacement . J Prosthet Dent. 76:1996;267-272.
-
(1996)
J Prosthet Dent
, vol.76
, pp. 267-272
-
-
Vermeulen, A.H.1
Keltjens, H.M.2
Van't Hof, M.A.3
Kayser, A.F.4
-
2
-
-
0017936951
-
Failure of removable partial denture castings during service
-
Lewis A.J. Failure of removable partial denture castings during service. J Prosthet Dent. 39:1978;147-149.
-
(1978)
J Prosthet Dent
, vol.39
, pp. 147-149
-
-
Lewis, A.J.1
-
3
-
-
0016747059
-
Masticatory function - A review of the literature. (II) Speed of movement of mandible, rate of chewing and forces developed in chewing
-
Bates J.F., Stafford G.D., Harrison A. Masticatory function - a review of the literature. (II) Speed of movement of mandible, rate of chewing and forces developed in chewing. J Oral Rehabil. 2:1975;349-361.
-
(1975)
J Oral Rehabil
, vol.2
, pp. 349-361
-
-
Bates, J.F.1
Stafford, G.D.2
Harrison, A.3
-
4
-
-
0004057280
-
Restorative dental materials
-
11th ed. St. Louis: Mosby
-
Craig R.G., Powers J.M. Restorative dental materials. 11th ed:2001;68-91 Mosby, St. Louis.
-
(2001)
, pp. 68-91
-
-
Craig, R.G.1
Powers, J.M.2
-
5
-
-
0029382643
-
Deflection fatigue of cobalt-chromium, titanium, and gold alloy cast denture clasp
-
Vallittu P.K., Kokkonen M. Deflection fatigue of cobalt-chromium, titanium, and gold alloy cast denture clasp. J Prosthet Dent. 74:1995;412-419.
-
(1995)
J Prosthet Dent
, vol.74
, pp. 412-419
-
-
Vallittu, P.K.1
Kokkonen, M.2
-
6
-
-
0031174236
-
Cobalt-chromium-titanium alloy for removable partial dentures
-
Iwama C.Y., Preston J.D. Cobalt-chromium-titanium alloy for removable partial dentures. Int J Prosthodont. 10:1997;309-317.
-
(1997)
Int J Prosthodont
, vol.10
, pp. 309-317
-
-
Iwama, C.Y.1
Preston, J.D.2
-
7
-
-
0031201763
-
Comparison of titanium and cobalt-chromium removable partial denture clasps
-
Bridgeman J.T., Marker V.A., Hummel S.K., Benson B.W., Pace L.L. Comparison of titanium and cobalt-chromium removable partial denture clasps. J Prosthet Dent. 78:1997;187-193.
-
(1997)
J Prosthet Dent
, vol.78
, pp. 187-193
-
-
Bridgeman, J.T.1
Marker, V.A.2
Hummel, S.K.3
Benson, B.W.4
Pace, L.L.5
-
8
-
-
0030228852
-
Fatigue resistance and stress of wrought-steel wire clasps
-
Vallittu P.K. Fatigue resistance and stress of wrought-steel wire clasps. J Prosthodont. 5:1996;186-192.
-
(1996)
J Prosthodont
, vol.5
, pp. 186-192
-
-
Vallittu, P.K.1
-
9
-
-
0022671492
-
Behavior of wrought wire clasps after repeated permanent deformation
-
Matheson G.R., Brudvik J.S., Nicholls J.I. Behavior of wrought wire clasps after repeated permanent deformation. J Prosthet Dent. 55:1986;226-231.
-
(1986)
J Prosthet Dent
, vol.55
, pp. 226-231
-
-
Matheson, G.R.1
Brudvik, J.S.2
Nicholls, J.I.3
-
10
-
-
0024761297
-
Rigidity of major connectors when subjected to bending and torsion forces
-
Ben-Ur Z., Matalon S., Aviv I., Cardash H.S. Rigidity of major connectors when subjected to bending and torsion forces. J Prosthet Dent. 62:1989;557-562.
-
(1989)
J Prosthet Dent
, vol.62
, pp. 557-562
-
-
Ben-Ur, Z.1
Matalon, S.2
Aviv, I.3
Cardash, H.S.4
-
11
-
-
0031229043
-
Comparative strengths of metal framework structures for removable partial dentures
-
Ohkubo C., Abe M., Miyata T., Obana J. Comparative strengths of metal framework structures for removable partial dentures. J Prosthet Dent. 78:1997;302-308.
-
(1997)
J Prosthet Dent
, vol.78
, pp. 302-308
-
-
Ohkubo, C.1
Abe, M.2
Miyata, T.3
Obana, J.4
-
12
-
-
0042965865
-
Partial removable prosthodontics
-
Philadelphia: WB Saunders
-
Kratochvil F.J. Partial removable prosthodontics. 1988;16-21 WB Saunders, Philadelphia.
-
(1988)
, pp. 16-21
-
-
Kratochvil, F.J.1
-
13
-
-
4243619548
-
Partial dentures
-
5th ed. Oxford: Blackwell Scientific Publications
-
Lammie G.A., Osborne J. Partial dentures. 5th ed:1987;189-224 Blackwell Scientific Publications, Oxford.
-
(1987)
, pp. 189-224
-
-
Lammie, G.A.1
Osborne, J.2
-
14
-
-
0004305258
-
McCracken's removable partial prosthodontics
-
10th ed. St. Louis: Mosby
-
McGivney G.P., Carr A.B., McCracken W.L. McCracken's removable partial prosthodontics. 10th ed:1999;77-91 Mosby, St. Louis.
-
(1999)
, pp. 77-91
-
-
McGivney, G.P.1
Carr, A.B.2
McCracken, W.L.3
-
15
-
-
0023014817
-
The fracture of cobalt-chromium alloy removable partial dentures
-
Ben-Ur Z., Patael H., Cardash H.S., Baharav H. The fracture of cobalt-chromium alloy removable partial dentures. Quintessence Int. 17:1986;797-801.
-
(1986)
Quintessence Int
, vol.17
, pp. 797-801
-
-
Ben-Ur, Z.1
Patael, H.2
Cardash, H.S.3
Baharav, H.4
-
16
-
-
0020215005
-
Replacement technique for a broken occlusal rest
-
Kazanoglu A., Smith E.H. Replacement technique for a broken occlusal rest. J Prosthet Dent. 48:1982;621-623.
-
(1982)
J Prosthet Dent
, vol.48
, pp. 621-623
-
-
Kazanoglu, A.1
Smith, E.H.2
-
17
-
-
0026862221
-
Dentin exposure and decay incidence when removable partial denture rest seats are prepared in tooth structure
-
Jones R.M., Goodacre C.J., Brown D.T., Munoz C.A., Rake P.C. Dentin exposure and decay incidence when removable partial denture rest seats are prepared in tooth structure. Int J Prosthodont. 5:1992;227-236.
-
(1992)
Int J Prosthodont
, vol.5
, pp. 227-236
-
-
Jones, R.M.1
Goodacre, C.J.2
Brown, D.T.3
Munoz, C.A.4
Rake, P.C.5
-
18
-
-
0034706173
-
The size of occlusal rest seats prepared for removable partial dentures
-
Culwick P.F., Howell P.G., Faigenblum M.J. The size of occlusal rest seats prepared for removable partial dentures. Br Dent J. 189:2000;318-322.
-
(2000)
Br Dent J
, vol.189
, pp. 318-322
-
-
Culwick, P.F.1
Howell, P.G.2
Faigenblum, M.J.3
-
19
-
-
0026887038
-
Fatigue strength of cantilevered metal frameworks for tissue-integrated prostheses
-
Stewart R.B., Desjardins R.P., Laney W.R., Chao E.Y. Fatigue strength of cantilevered metal frameworks for tissue-integrated prostheses. J Prosthet Dent. 68:1992;83-92.
-
(1992)
J Prosthet Dent
, vol.68
, pp. 83-92
-
-
Stewart, R.B.1
Desjardins, R.P.2
Laney, W.R.3
Chao, E.Y.4
-
20
-
-
0023302773
-
The longitudinal clinical efficacy of osseointegrated dental implants: A 3-year report
-
Cox J.F., Zarb G.A. The longitudinal clinical efficacy of osseointegrated dental implants a 3-year report . Int J Oral Maxillofac Implants. 2:1987;91-100.
-
(1987)
Int J Oral Maxillofac Implants
, vol.2
, pp. 91-100
-
-
Cox, J.F.1
Zarb, G.A.2
-
21
-
-
0021777102
-
Alternative prosthodontic superstructure designs
-
Cox J., Zarb G. Alternative prosthodontic superstructure designs. Swed Dent J Suppl. 28:1985;71-75.
-
(1985)
Swed Dent J Suppl
, vol.28
, pp. 71-75
-
-
Cox, J.1
Zarb, G.2
-
22
-
-
0032246057
-
Effect of water and artificial saliva on the low cycle fatigue resistance of cobalt-chromium dental alloy
-
Lassila L.V., Vallittu P.K. Effect of water and artificial saliva on the low cycle fatigue resistance of cobalt-chromium dental alloy. J Prosthet Dent. 80:1998;708-713.
-
(1998)
J Prosthet Dent
, vol.80
, pp. 708-713
-
-
Lassila, L.V.1
Vallittu, P.K.2
-
23
-
-
0008795137
-
Studies related to the fracture of partial dentures. Flexural fatigue of a cobalt-chromium alloy
-
Bates J.F. Studies related to the fracture of partial dentures. Flexural fatigue of a cobalt-chromium alloy. Br Dent J. 119:1965;532-537.
-
(1965)
Br Dent J
, vol.119
, pp. 532-537
-
-
Bates, J.F.1
-
24
-
-
0013842193
-
The mechanical properties of the cobalt-chromium alloys and their relation to partial denture design
-
Bates J.F. The mechanical properties of the cobalt-chromium alloys and their relation to partial denture design. Br Dent J. 119:1965;389-396.
-
(1965)
Br Dent J
, vol.119
, pp. 389-396
-
-
Bates, J.F.1
-
25
-
-
0024869409
-
Fatigue properties of dental alloys: 12% Au-Pd-Ag alloy and Type III gold alloy
-
Kato H. [Fatigue properties of dental alloys: 12% Au-Pd-Ag alloy and Type III gold alloy.] Aichi Gakuin Daigaku Shigakkai Shi 1989;27:1017-27.
-
(1989)
Aichi Gakuin Daigaku Shigakkai Shi
, vol.27
, pp. 1017-1027
-
-
Kato, H.1
-
28
-
-
0021378809
-
Ductility of a dental Ag-Pd-Cu-Au alloy
-
Syverud M., Hero H. Ductility of a dental Ag-Pd-Cu-Au alloy. Acta Odontol Scand. 42:1984;47-52.
-
(1984)
Acta Odontol Scand
, vol.42
, pp. 47-52
-
-
Syverud, M.1
Hero, H.2
-
29
-
-
0021520092
-
Management of loading forces on mandibular distal-extension prostheses. Part I: Evaluation of concepts for design
-
Monteith B.D. Management of loading forces on mandibular distal-extension prostheses. Part I Evaluation of concepts for design . J Prosthet Dent. 52:1984;673-681.
-
(1984)
J Prosthet Dent
, vol.52
, pp. 673-681
-
-
Monteith, B.D.1
-
30
-
-
0028441348
-
Fatigue resistance of soldered joints: A methodological study
-
Wiskott H.W., Nicholls J.I., Belser U.C. Fatigue resistance of soldered joints a methodological study . Dent Mater. 10:1994;215-220.
-
(1994)
Dent Mater
, vol.10
, pp. 215-220
-
-
Wiskott, H.W.1
Nicholls, J.I.2
Belser, U.C.3
-
31
-
-
0029262154
-
Stress fatigue: Basic principles and prosthodontic implications
-
Wiskott H.W., Nicholls J.I., Belser U.C. Stress fatigue basic principles and prosthodontic implications . Int J Prosthodont. 8:1995;105-116.
-
(1995)
Int J Prosthodont
, vol.8
, pp. 105-116
-
-
Wiskott, H.W.1
Nicholls, J.I.2
Belser, U.C.3
-
32
-
-
0003958763
-
-
Ohio: American Society for Metals
-
American Society for Metals. Metals Handbook Vol. 8. 9th ed. Ohio: American Society for Metals; 1985. p. 363-435.
-
(1985)
Metals Handbook Vol. 8. 9th Ed.
, pp. 363-435
-
-
-
33
-
-
0003556607
-
An atlas of metal damage
-
London: Wolfe Publishing Ltd
-
Engel L., Klingele H. An atlas of metal damage. 1981;41-89 Wolfe Publishing Ltd, London.
-
(1981)
, pp. 41-89
-
-
Engel, L.1
Klingele, H.2
|