Volumn 14, Issue 3, 2003, Pages 286-293

A conical implant-abutment interface at the level of the marginal bone improves the distribution of stresses in the supporting bone: An axisymmetric finite element analysis

Author keywords

Bone stress; Implant neck; Implant abutment interface; Retention elements; Surface texture

Indexed keywords

ARTICLE; BONE STRESS; DENTAL SURGERY; DENTURE; MANDIBLE; ORTHODONTICS; OSTEOLYSIS; RISK FACTOR; TOOTH IMPLANTATION; BIOLOGICAL MODEL; COMPUTER SIMULATION; ELASTICITY; FINITE ELEMENT ANALYSIS; HUMAN; JAW; MECHANICAL STRESS; PATHOPHYSIOLOGY; SURFACE PROPERTY; TOOTH PROSTHESIS; WEIGHT BEARING;

EID: 0041380736     PISSN: 09057161     EISSN: None     Source Type: Journal    
DOI: 10.1034/j.1600-0501.2003.140306.x     Document Type: Article
Times cited : (152)

References (30)
  • 2
    • 0029175459 scopus 로고
    • Implants for single-tooth replacement. A clinical and experimental study on the Brånemark CeraOne System
    • Andersson, B. (1995) Implants for single-tooth replacement. A clinical and experimental study on the Brånemark CeraOne System. Swedish Dental Journal 108 (Suppl.): 1-41.
    • (1995) Swedish Dental Journal , vol.108 , Issue.SUPPL. , pp. 1-41
    • Andersson, B.1
  • 3
    • 0019844822 scopus 로고
    • Fatigue bahavior of adult cortical bone: The influence of mean strain and strain range
    • Carter, D.R., Caler, W.E., Spengler, D.M. & Frankel, V.H. (1981) Fatigue bahavior of adult cortical bone: the influence of mean strain and strain range. Acta Orthopaedica Scandinavica 52: 481-490.
    • (1981) Acta Orthopaedica Scandinavica , vol.52 , pp. 481-490
    • Carter, D.R.1    Caler, W.E.2    Spengler, D.M.3    Frankel, V.H.4
  • 4
    • 0023162010 scopus 로고
    • Trabecular bone density and loading history: Regulation of connective tissue biology by mechanical energy
    • Carter, D.R., Fyhrie, D.P & Whalen, R.T. (1987) Trabecular bone density and loading history: regulation of connective tissue biology by mechanical energy. Journal of Biomechanics 20: 785-794.
    • (1987) Journal of Biomechanics , vol.20 , pp. 785-794
    • Carter, D.R.1    Fyhrie, D.P.2    Whalen, R.T.3
  • 5
  • 6
    • 0030155399 scopus 로고    scopus 로고
    • The effect of subcrestal placement of the polished surface of ITI implants on marginal soft and hard tissues
    • Hämmerle, C.H., Brägger, U., Bürgin, W. & Lang, N.P. (1996) The effect of subcrestal placement of the polished surface of ITI implants on marginal soft and hard tissues. Clinical Oral Implants Research 7: 111-119.
    • (1996) Clinical Oral Implants Research , vol.7 , pp. 111-119
    • Hämmerle, C.H.1    Brägger, U.2    Bürgin, W.3    Lang, N.P.4
  • 7
    • 0033212422 scopus 로고    scopus 로고
    • The implant neck: Smooth or provided with retention elements. A biomechanical approach
    • Hansson, S. (1999) The implant neck: smooth or provided with retention elements. A biomechanical approach. Clinical Oral Implants Research 10: 394-405.
    • (1999) Clinical Oral Implants Research , vol.10 , pp. 394-405
    • Hansson, S.1
  • 8
    • 0034570059 scopus 로고    scopus 로고
    • Implant-abutment interface: Biomechanical study of flat top versus conical
    • Hansson, S. (2000) Implant-abutment interface: biomechanical study of flat top versus conical. Clinical Implant Dentistry and Related Research 2: 33-41.
    • (2000) Clinical Implant Dentistry and Related Research , vol.2 , pp. 33-41
    • Hansson, S.1
  • 12
    • 0015130955 scopus 로고
    • Hard tissue as a composite material. I. Bounds on the elastic behaviour
    • Katz, J.L. (1971) Hard tissue as a composite material. I. Bounds on the elastic behaviour. Journal of Biomechanics 4: 455-473.
    • (1971) Journal of Biomechanics , vol.4 , pp. 455-473
    • Katz, J.L.1
  • 13
    • 0024146347 scopus 로고
    • The stress distribution of the hydroxyapatite implant under the vertical load by the two-dimensional finite element method
    • Kitoh, M., Matsushita, Y., Yamane, S., Ikeda, H. & Suetsugu, T. (1988) The stress distribution of the hydroxyapatite implant under the vertical load by the two-dimensional finite element method. Journal of Oral Implantology 14: 65-72.
    • (1988) Journal of Oral Implantology , vol.14 , pp. 65-72
    • Kitoh, M.1    Matsushita, Y.2    Yamane, S.3    Ikeda, H.4    Suetsugu, T.5
  • 14
    • 0024675462 scopus 로고
    • Die Knochenresorption an der Eintrittstelle osseointegrierter Implantate - Ein biomechanisches Phänomen. Eine Finite-Element-Studie
    • Mailath, G., Stoiber, B., Watzek, G. & Matejka, M. (1989) Die Knochenresorption an der Eintrittstelle osseointegrierter Implantate - ein biomechanisches Phänomen. Eine Finite-Element-Studie. Zeitschrift für Stomatologie 86: 207-216.
    • (1989) Zeitschrift für Stomatologie , vol.86 , pp. 207-216
    • Mailath, G.1    Stoiber, B.2    Watzek, G.3    Matejka, M.4
  • 15
    • 0030155566 scopus 로고    scopus 로고
    • Marginal bone levels at Brånemark system implants used for single tooth restorations. The influence of implant design and anatomical region
    • Malevez, C., Hermans, M. & Daelemans, P. (1996) Marginal bone levels at Brånemark system implants used for single tooth restorations. The influence of implant design and anatomical region. Clinical Oral Implants Research 7: 162-169.
    • (1996) Clinical Oral Implants Research , vol.7 , pp. 162-169
    • Malevez, C.1    Hermans, M.2    Daelemans, P.3
  • 16
    • 0027620595 scopus 로고
    • A three-dimensional, finite element analysis of bone around dental implants in an edentulous human mandible
    • Meijer, H.J.A., Starmans, F.J.M., Steen, W.H.A. & Bosnian, F. (1993a) A three-dimensional, finite element analysis of bone around dental implants in an edentulous human mandible. Archives in Oral Biology 38: 491-496.
    • (1993) Archives in Oral Biology , vol.38 , pp. 491-496
    • Meijer, H.J.A.1    Starmans, F.J.M.2    Steen, W.H.A.3    Bosnian, F.4
  • 17
    • 0027571102 scopus 로고
    • A comparison of three finite element models of an edentulous mandible provided with implants
    • Meijer, H.J.A., Starmans, F.J.M., Bosman, F. & Steen, W.H.A. (1993b) A comparison of three finite element models of an edentulous mandible provided with implants. Journal of Oral Rehabilitation 20: 147-157.
    • (1993) Journal of Oral Rehabilitation , vol.20 , pp. 147-157
    • Meijer, H.J.A.1    Starmans, F.J.M.2    Bosman, F.3    Steen, W.H.A.4
  • 18
    • 0032192923 scopus 로고    scopus 로고
    • The use of a conical fixture design for fixed partial prostheses. A preliminary report
    • Nordin, T., Jönsson, G., Nelvig, P. & Rasmusson, L. (1998) The use of a conical fixture design for fixed partial prostheses. A preliminary report. Clinical Oral Implants Research 9: 343-347.
    • (1998) Clinical Oral Implants Research , vol.9 , pp. 343-347
    • Nordin, T.1    Jönsson, G.2    Nelvig, P.3    Rasmusson, L.4
  • 19
    • 0032039790 scopus 로고    scopus 로고
    • Marginal bone levels at single tooth implants with a conical fixture design. The influence of surface macro- and microstructure
    • Norton, M. (1998) Marginal bone levels at single tooth implants with a conical fixture design. The influence of surface macro-and microstructure. Clinical Oral Implants Research 9: 91-99.
    • (1998) Clinical Oral Implants Research , vol.9 , pp. 91-99
    • Norton, M.1
  • 23
    • 0030152432 scopus 로고    scopus 로고
    • Microdamage and osteocyte-lacuna strain in bone: A microstructural finite element analysis
    • Prendergast, P.J. & Huiskes, R. (1996) Microdamage and osteocyte-lacuna strain in bone: a microstructural finite element analysis. Journal of Biomechanical Engineering 118: 240-246.
    • (1996) Journal of Biomechanical Engineering , vol.118 , pp. 240-246
    • Prendergast, P.J.1    Huiskes, R.2
  • 25
    • 0026921680 scopus 로고
    • Fixture design and overload influence marginal bone loss and fixture success in the Brånemark system
    • Quirynen, M., Naert, I. & van Steenberghe, D. (1992) Fixture design and overload influence marginal bone loss and fixture success in the Brånemark system. Clinical Oral Implants Research 3: 104-111.
    • (1992) Clinical Oral Implants Research , vol.3 , pp. 104-111
    • Quirynen, M.1    Naert, I.2    Van Steenberghe, D.3
  • 27
    • 0025333345 scopus 로고
    • Rigid endosseous implant used as anchorage to protract molars and close an atrophic extraction site
    • Roberts, W.E., Marshall, K.J. & Mozsay, P.G. (1990) Rigid endosseous implant used as anchorage to protract molars and close an atrophic extraction site. Angle Orthodontist 60: 135-152.
    • (1990) Angle Orthodontist , vol.60 , pp. 135-152
    • Roberts, W.E.1    Marshall, K.J.2    Mozsay, P.G.3
  • 29
    • 0042548099 scopus 로고    scopus 로고
    • The concept of the ITI implants
    • Schroeder, A., Sutter, F., Buser, D. & Krekeler, G., eds. Stuttgart: Thieme Verlag.
    • Sutler, F. (1996) The concept of the ITI implants. In: Schroeder, A., Sutter, F., Buser, D. & Krekeler, G., eds. Oral implantology. Basics, ITI hollow cylinder system, 114-223. Stuttgart: Thieme Verlag.
    • (1996) Oral Implantology. Basics, ITI Hollow Cylinder System , pp. 114-223
    • Sutler, F.1
  • 30
    • 0033251930 scopus 로고    scopus 로고
    • Lack of integration of smooth titanium surfaces: A working hypothesis based on strains generated in the surrounding bone
    • Wiskott, H.W. & Belser, U.C. (1999) Lack of integration of smooth titanium surfaces: a working hypothesis based on strains generated in the surrounding bone. Clinical Oral Implants Research 10: 429-444.
    • (1999) Clinical Oral Implants Research , vol.10 , pp. 429-444
    • Wiskott, H.W.1    Belser, U.C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.